{"product_id":"epro-con010-pr6426-010-140-eddy-current-displacement-system","title":"Epro CON010+PR6426\/010-140 Eddy Current Displacement System","description":"\u003ch3\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePR6426\/010-140 + CON010\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emeasurement solution from\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"hover:entity-accent entity-underline inline cursor-pointer align-baseline\"\u003e\u003cspan class=\"whitespace-normal\"\u003eEmerson Electric\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eis a heavy-duty eddy-current based monitoring system engineered for large rotor diameter machinery. It is designed to deliver precise, continuous tracking of shaft movement and vibration behavior in high-energy turbomachinery environments.\u003c\/p\u003e\n\u003cp\u003eThis configuration combines a 32 mm probe with a dedicated signal conditioning module. The probe performs non-contact measurement of shaft dynamics, while the CON010 converter transforms raw eddy-current signals into standardized analog outputs suitable for protection systems, PLCs, and condition monitoring platforms.\u003c\/p\u003e\n\u003cp\u003eThe system is optimized for large-shaft applications where extended measurement range, thermal stability, and high dynamic accuracy are required.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSystem Architecture and Function\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eNon-contact eddy-current sensing for large rotating shafts\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHigh-stability signal conditioning via CON010 converter\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupports continuous monitoring of vibration and axial movement\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSuitable for long-term operation in high-temperature environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDesigned for integration into API 670-compliant protection systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch4\u003e\u003cstrong\u003eProbe Unit (PR6426\/010-140)\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eModel:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePR6426\/010-140\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProbe Diameter: 32 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMeasurement Range: up to 14 mm displacement (radial\/axial)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSensitivity: 2 V\/mm (50.8 mV\/mil), linearity ≤ ±1.5%\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMinimum Shaft Diameter: ≥ 200 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFrequency Response: DC to 10 kHz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTarget Material: Ferromagnetic steel (e.g., 42CrMo4 \/ equivalent)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOutput Type: Analog displacement signal (pre-conditioning stage)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmental Performance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eOperating Temperature: –35 °C to +160 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eShort-term Exposure: up to 200 °C (≤4 hours)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePressure Resistance: 6,500 hPa (approx. 94 psi)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eShock Resistance: up to 40 g\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProtection Rating: IP66\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical Construction\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eHousing: Stainless steel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSensing Tip: PEEK high-temperature composite\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCable Type: PTFE insulated (armored or standard options)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCable Length Options: 4 m \/ 5 m \/ 8 m \/ 10 m\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWeight: approx. 800 g (probe with 1 m cable)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003e\u003cstrong\u003eSignal Converter (CON010)\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eFunction: Signal amplification and linearization\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupply Voltage: –23 V to –32 V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOutput Signal: –4 V to –20 V DC with superimposed AC vibration component\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBandwidth: 0 to 20 kHz (–3 dB)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSystem Linearity Error: ≤ 2.5%\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmental Conditions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eOperating Temperature: –30 °C to +100 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProtection Class: IP20 (panel-mounted module)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMax Sensor Cable Distance: recommended ≤ 5 m\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eSystem-Level Performance\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMeasured Parameters:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eRadial shaft vibration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAxial displacement\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eShaft eccentricity\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSpeed \/ keyphasor signals\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003eSystem Accuracy: ±0.1% full scale (application dependent)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDynamic Range: DC to 20 kHz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompliance Standards: API 670, ISO 10817-1, DIN 45670, ATEX, IECEx, CSA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication Areas\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePR6426\/010-140 + CON010\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esystem is typically deployed in large rotating machinery where high stability and extended measurement range are required:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSteam and gas turbines\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHydro turbines\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLarge centrifugal compressors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIndustrial pumps and fans\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHeavy-duty gearbox and rotor systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Why is a 32 mm probe used in this system?\u003c\/strong\u003e\u003cbr\u003eA: The larger probe increases sensitivity and stability when monitoring large-diameter shafts above 200 mm.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the system operate at high temperatures?\u003c\/strong\u003e\u003cbr\u003eA: Yes, the probe supports continuous operation up to 160 °C and short-term exposure up to 200 °C.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the role of the CON010 module?\u003c\/strong\u003e\u003cbr\u003eA: It conditions raw eddy-current signals into standardized analog outputs for control and protection systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is this system suitable for safety-critical monitoring?\u003c\/strong\u003e\u003cbr\u003eA: Yes, it is designed for API 670-compliant applications and supports global hazardous-area certifications.\u003c\/p\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":43214905966682,"sku":"CON010+PR6426\/010-140","price":178.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/PR6423000-141.jpg?v=1769754735","url":"https:\/\/www.plcmasters.com\/products\/epro-con010-pr6426-010-140-eddy-current-displacement-system","provider":"PLC Masters Ltd.","version":"1.0","type":"link"}