{"product_id":"epro-con021-pr6423-010-000-cn-eddy-current-displacement-sensor-system","title":"Epro CON021+PR6423\/010-000-CN Eddy Current Displacement Sensor System","description":"\u003ch3\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePR6423\/010-000-CN + CON021\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efrom Emerson Epro is a non-contact measurement solution developed for continuous monitoring of shaft behavior in rotating equipment. This system combines an eddy-current proximity probe with a dedicated signal conditioning module to deliver stable and accurate displacement data under demanding industrial conditions.\u003c\/p\u003e\n\u003cp\u003eIt is widely implemented in machinery protection systems where precise vibration and position feedback is required for safe and efficient operation.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSystem Configuration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003ePR6423\/010-000-CN Proximity Probe\u003c\/strong\u003e\u003cbr\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePR6423\/010-000-CN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis an 8 mm eddy-current sensor designed to withstand elevated temperatures, vibration, and contamination. The CN designation refers to a region-specific configuration, typically including connector and compliance adaptations.\u003c\/p\u003e\n\u003cp\u003eThe probe enables:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eRadial shaft vibration monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAxial displacement measurement\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRotor position tracking\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGap voltage reference output\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe “010-000” suffix defines probe geometry, calibration compatibility, and cable arrangement, with “000” generally indicating a short or configurable cable option.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCON021 Signal Driver\u003c\/strong\u003e\u003cbr\u003eThe CON021 module provides excitation energy to the probe and converts the measured signal into a linear voltage output. It ensures signal conditioning, stability, and compatibility with industrial monitoring platforms.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003ePR6423\/010-000-CN Probe\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMeasurement Principle: Eddy current, non-contact\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTip Size: 8 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMeasuring Range: ±1.0 mm to ±2.0 mm (dependent on calibration)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSensitivity: 8 mV\/µm (system calibrated)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFrequency Response: Up to 10 kHz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLinearity: ≤ ±1% of full scale\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eResolution: Better than 1 µm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOperating Temperature: –35 °C to +180 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProtection Rating: ≥ IP65\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHousing Material: Stainless steel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCable Type: Integrated coaxial cable (short or configurable length)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConnector: Epro standard coaxial connector\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInstallation: Threaded mounting or bracket fixing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCON021 Driver\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eDevice Type: Signal conditioner for proximity probes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupported Probes: PR6422, PR6423, PR6424, PR6426 series\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower Requirement: 24 V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eExcitation: High-frequency oscillator\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOutput Signal: Analog voltage proportional to displacement (typically 0–20 V)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSensitivity: 8 mV\/µm (with matched probe)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBandwidth: Up to 10 kHz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAccuracy: ≤ ±1% FS\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDiagnostic Functions:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eProbe condition monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCable fault detection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGap voltage supervision\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003eOperating Temperature: –20 °C to +70 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMounting Options: DIN rail or system rack\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eSystem Performance Characteristics\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSensitivity: 8 mV\/µm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLinear Measurement Range: Up to ±2 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFrequency Bandwidth: Up to 10 kHz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAccuracy: ≤ ±1% FS\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOutput Format: Linear analog voltage\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication Fields\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSteam and gas turbine monitoring systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompressor and blower vibration analysis\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHigh-speed motor and generator protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGearbox condition monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePetrochemical and energy sector rotating equipment\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Advantages\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eNon-contact sensing avoids mechanical wear and drift\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHigh resistance to thermal stress and electromagnetic interference\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStable output over long operating periods\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompatible with MMS 6000, MMS 3000, and VM600 platforms\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFlexible installation with modular components\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What does the “000” cable code represent?\u003c\/strong\u003e\u003cbr\u003eA: It generally indicates a short or customizable cable configuration. Exact length depends on the specific order variant.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the CON021 be used with other probe models?\u003c\/strong\u003e\u003cbr\u003eA: Yes, it supports multiple probes in the PR642x series, but calibration must match for accurate measurements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What type of signal is provided to monitoring systems?\u003c\/strong\u003e\u003cbr\u003eA: A linear voltage output proportional to displacement, typically within a 0–20 V range.\u003c\/p\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":43284459225178,"sku":"CON021+PR6423\/010-000-CN","price":178.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/PR6423000-1112_9cd8d753-694f-4891-b258-6547272c9be3.jpg?v=1777367949","url":"https:\/\/www.plcmasters.com\/products\/epro-con021-pr6423-010-000-cn-eddy-current-displacement-sensor-system","provider":"PLC Masters Ltd.","version":"1.0","type":"link"}