{"product_id":"epro-con021-pr6423-010-100-cn-eddy-current-proximity-measurement-system","title":"Epro CON021+PR6423\/010-100-CN Eddy Current Proximity Measurement System","description":"\u003ch3\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePR6423\/010-100-CN + CON021\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eassembly from Emerson Epro is engineered for continuous, non-contact measurement of shaft movement in rotating machinery. This system applies eddy-current sensing technology to capture precise displacement and vibration data, even in installations requiring extended cable routing.\u003c\/p\u003e\n\u003cp\u003eBy combining a rugged probe with a dedicated signal conditioning unit, the system ensures stable output signals suitable for machinery protection, condition monitoring, and diagnostic applications.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSystem Architecture\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003ePR6423\/010-100-CN Eddy Current Probe\u003c\/strong\u003e\u003cbr\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePR6423\/010-100-CN\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ebelongs to the PR6423 series and features an 8 mm sensing tip optimized for high-reliability operation in industrial environments. The CN version represents a region-specific configuration with defined connector standards.\u003c\/p\u003e\n\u003cp\u003eThe “010-100” designation typically corresponds to calibration pairing and an extended cable configuration, commonly around 10 meters, enabling installation flexibility for large machinery layouts.\u003c\/p\u003e\n\u003cp\u003eMeasurement functions include:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eRadial shaft vibration monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAxial displacement detection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRotor position measurement\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGap voltage reference output\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCON021 Signal Conditioner\u003c\/strong\u003e\u003cbr\u003eThe CON021 module drives the probe with a high-frequency signal and converts the response into a proportional voltage output. It provides signal stabilization, linearization, and diagnostic capabilities required for integration into monitoring systems.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003ePR6423\/010-100-CN Probe\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMeasurement Principle: Eddy current, non-contact\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTip Diameter: 8 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMeasurement Range: ±1.0 mm to ±2.0 mm (calibration-dependent)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSensitivity: 8 mV\/µm (system calibrated)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFrequency Response: Up to 10 kHz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLinearity: ≤ ±1% of full scale\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eResolution: Better than 1 µm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOperating Temperature: –35 °C to +180 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProtection Rating: ≥ IP65\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHousing Material: Stainless steel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCable Length: Approx. 10 m integrated coaxial cable\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConnector: Epro standard coaxial connector\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMounting Options: Threaded or clamp-type installation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCON021 Driver Module\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eFunction: Probe driver and signal conditioning unit\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompatible Probes: PR6422, PR6423, PR6424, PR6426 series\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupply Voltage: 24 V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eExcitation Method: Internal high-frequency oscillator\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOutput Signal: Linear analog voltage proportional to displacement (typically 0–20 V)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSensitivity: 8 mV\/µm (with matched probe)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFrequency Range: Up to 10 kHz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAccuracy: ≤ ±1% FS\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDiagnostics:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eProbe status monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCable break detection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGap voltage supervision\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003eOperating Temperature: –20 °C to +70 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMounting: DIN rail or rack integration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eSystem Performance Summary\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSensitivity: 8 mV\/µm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLinear Measurement Range: Up to ±2 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBandwidth: Up to 10 kHz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAccuracy: ≤ ±1% FS\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOutput Signal: Analog voltage\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication Areas\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSteam and gas turbine shaft monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompressor and blower vibration analysis\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHigh-speed motor and generator protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGearbox condition monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePetrochemical and process industry rotating equipment\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eContactless measurement eliminates wear and drift\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupports long cable installations without signal degradation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eResistant to thermal variation and electromagnetic interference\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompatible with MMS 6000, MMS 3000, and VM600 systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eModular structure for simplified maintenance and replacement\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the advantage of the “100” cable configuration?\u003c\/strong\u003e\u003cbr\u003eA: It allows installation over longer distances, typically around 10 meters, making it suitable for large equipment layouts.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can this system be used with other PR642x probes?\u003c\/strong\u003e\u003cbr\u003eA: The CON021 supports multiple probe types, but proper calibration matching is required for accurate measurement.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What type of output is provided?\u003c\/strong\u003e\u003cbr\u003eA: A linear voltage signal proportional to shaft displacement, usually within a 0–20 V range.\u003c\/p\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":43284463353946,"sku":"CON021+PR6423\/010-100-CN","price":178.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/PR6423000-1111_ff3f142f-a9ef-4feb-92ac-6b6c24ef7027.jpg?v=1777368789","url":"https:\/\/www.plcmasters.com\/products\/epro-con021-pr6423-010-100-cn-eddy-current-proximity-measurement-system","provider":"PLC Masters Ltd.","version":"1.0","type":"link"}