{"product_id":"epro-mmg1070-02ts-mms-monitoring-module","title":"Epro MMG1070\/02TS MMS Monitoring Module","description":"\u003ch3\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMMG1070\/02TS\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a rack-mounted monitoring unit used within Emerson EPRO MMS protection platforms. It processes signals from eddy current proximity probes and converts raw vibration data into evaluated mechanical condition parameters for rotating machinery supervision.\u003c\/p\u003e\n\u003cp\u003eThis module is designed for continuous monitoring and protective shutdown logic in high-criticality equipment environments.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSystem Architecture Integration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe module operates as part of a complete measurement chain:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eEddy current probe (PR642x series)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSignal conditioning driver (CON series)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRack-based monitoring module (\u003cstrong\u003eMMG1070\/02TS\u003c\/strong\u003e)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eIt evaluates conditioned signals and executes alarm, warning, and trip logic based on configured thresholds.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eGeneral Characteristics\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eModel:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMMG1070\/02TS\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSeries: Emerson EPRO MMS 3000 \/ MMS 6000 platform\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFunction: Signal evaluation, vibration monitoring, protection logic execution\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInstallation type: Plug-in rack module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eInput Interface\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eCompatible probe systems: PR6422 \/ PR6423 \/ PR6424 \/ PR6426\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInput signal source: CON-series signal conditioner output\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMeasured parameters:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eShaft vibration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRadial displacement\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAxial position\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGap voltage monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSignal Processing Performance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eFrequency response: up to 10 kHz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSystem accuracy: typically ±1% of full scale (dependent on calibration chain)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSensitivity compatibility: 8 mV\/µm system standard (probe-dependent)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDynamic range: optimized for high-speed rotating machinery\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOutput and Control Functions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eAnalog outputs: 0–20 mA \/ 4–20 mA (configuration dependent)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRelay outputs: alarm and trip contacts\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDigital communication: MMS system rack bus interface\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThreshold configuration: software or hardware selectable (variant dependent)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eElectrical Design\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003ePower supply: backplane powered via MMS rack\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIsolation: galvanically isolated input\/output\/system bus channels\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDiagnostics:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eProbe fault detection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCable integrity monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDriver signal validation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInternal module health check\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eMechanical and Environmental Data\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eOperating temperature: –20 °C to +70 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStorage temperature: –40 °C to +85 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHumidity tolerance: up to 95% non-condensing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEMI protection: high immunity design for industrial electrical environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMounting format: standard MMS rack insertion module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication Areas\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSteam and gas turbine protection systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompressor vibration monitoring racks\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHigh-speed generator supervision\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIndustrial gearbox condition tracking\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePetrochemical rotating equipment safety systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eContinuous condition monitoring installations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eEngineering Notes\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMMG1070\/02TS\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis designed for system-level decision processing rather than direct sensing. Performance depends on correct calibration of probe, driver, and rack module as a unified measurement chain within the MMS architecture.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Does the MMG1070\/02TS measure vibration directly?\u003c\/strong\u003e\u003cbr\u003eNo. It processes signals from external eddy current probe systems and evaluates vibration data.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Is it compatible with all PR6423 probes?\u003c\/strong\u003e\u003cbr\u003eIt supports PR642x series probes when paired with compatible CON-series drivers.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Can it trigger shutdown actions?\u003c\/strong\u003e\u003cbr\u003eYes. It includes configurable relay outputs for alarm and trip functions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: Is it part of a rack system?\u003c\/strong\u003e\u003cbr\u003eYes. It is designed for installation in Emerson MMS 3000\/6000 rack-based monitoring systems.\u003c\/p\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":43284346110042,"sku":"MMG1070\/02TS","price":178.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/MMG107002TS2.jpg?v=1777363144","url":"https:\/\/www.plcmasters.com\/products\/epro-mmg1070-02ts-mms-monitoring-module","provider":"PLC Masters Ltd.","version":"1.0","type":"link"}