{"product_id":"epro-pr6424-010-010-eddy-current-displacement-sensor","title":"Epro PR6424\/010-010 Eddy Current Displacement Sensor","description":"\u003ch3\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePR6424\/010-010\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esensor from\u003cspan\u003e \u003c\/span\u003e\u003cspan class=\"hover:entity-accent entity-underline inline cursor-pointer align-baseline\"\u003eEmerson Electric\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003eEPRO portfolio is a non-contact eddy current probe engineered for precise measurement of shaft dynamics in rotating equipment. With a 16 mm probe tip, this sensor is optimized for monitoring radial vibration, axial displacement, and shaft position in critical turbomachinery.\u003c\/p\u003e\n\u003cp\u003eDesigned for integration with EPRO signal converters such as the CON0xx series, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePR6424\/010-010\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eforms part of a complete condition monitoring chain compliant with API 670 requirements. Its robust construction and wide operating temperature range allow stable operation in high-speed and high-temperature industrial environments.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFunctional Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eNon-contact measurement eliminates mechanical wear\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHigh-frequency response suitable for dynamic vibration analysis\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStable output characteristics when paired with EPRO preamplifiers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDesigned for continuous monitoring of critical rotating assets\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSuitable for hazardous areas with certified system configuration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eGeneral Characteristics\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eModel:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePR6424\/010-010\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProduct Type: Eddy Current Displacement and Vibration Sensor\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProbe Diameter: 16 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eManufacturing Origin: Germany\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMeasurement Performance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMeasurement Parameters: Shaft displacement, axial position, eccentricity, vibration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMeasurement Range:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eTypical: ±2 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eExtended variants: up to 10 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003eSensitivity: 4 V\/mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLinearity Deviation: ≤ ±1.5%\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFrequency Bandwidth: 0 to 15 kHz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMeasurement Accuracy: ≤ 1.0% (with compatible signal converter)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTarget Material: Ferromagnetic steel (e.g., 42CrMo4)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical Data\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eOutput Signal Options:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eDynamic AC voltage (vibration monitoring)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDC voltage with superimposed AC component (system-dependent)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003eOutput Range: Typically –4 V to –20 V (via EPRO driver\/converter)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmental Conditions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eOperating Temperature:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eStandard probe: –40 °C to +120 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHigh-temperature tip variant: up to +380 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003eStorage Temperature: –50 °C to +125 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRelative Humidity: Up to 100% (condensing allowed)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProtection Class: IP67\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eShock Resistance: Up to 40 g\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical Properties\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eHousing Material: Stainless steel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSensor Tip: PEEK (high-temperature configuration)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMounting Options: Threaded (M10×1 or M18×1.5) or flange mounting\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNominal Air Gap: Approximately 2.7 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDimensions: 240 × 230 × 40 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWeight: 0.58 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCable and Connection Options\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eCable Types: Armored or standard industrial cable\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConnector Options: LEMO connector or open-ended leads\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAvailable Lengths: 4 m, 5 m, 8 m, 10 m\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCompliance and Certifications\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eCE, RoHS\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eATEX \/ IECEx (depending on system configuration)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAPI 670 compliant when used within a complete EPRO monitoring system\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication Areas\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ePR6424\/010-010\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esensor is deployed in condition monitoring and protection systems for:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSteam and gas turbines\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCentrifugal and axial compressors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIndustrial pumps and fans\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHigh-speed electric motors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCritical rotating equipment in process industries\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What system components are required for operation?\u003c\/strong\u003e\u003cbr\u003eA: The sensor must be used with a compatible EPRO signal converter (e.g., CON021 or similar) to generate calibrated output signals.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is the sensor suitable for high-temperature environments?\u003c\/strong\u003e\u003cbr\u003eA: Yes, specific probe variants support temperatures up to +380 °C at the sensing tip.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the typical installation gap?\u003c\/strong\u003e\u003cbr\u003eA: The recommended nominal air gap is approximately 2.7 mm, depending on calibration and system setup.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can it be used in hazardous areas?\u003c\/strong\u003e\u003cbr\u003eA: Yes, when combined with certified converters and installed per ATEX\/IECEx requirements.\u003c\/p\u003e","brand":"Emerson","offers":[{"title":"Default Title","offer_id":43214712373338,"sku":"PR6424\/010-010","price":178.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/CON021_PR6424001-010.jpg?v=1769579723","url":"https:\/\/www.plcmasters.com\/products\/epro-pr6424-010-010-eddy-current-displacement-sensor","provider":"PLC Masters Ltd.","version":"1.0","type":"link"}