{"product_id":"ge-is200emcsg1aab-exciter-multibridge-conduction-sensor-card","title":"GE IS200EMCSG1AAB Exciter Multibridge Conduction Sensor Card","description":"\u003ch3\u003eProduct Overview\u003c\/h3\u003e\n\u003cp\u003eThe GE IS200EMCSG1AAB is a high-precision Exciter Multibridge Conduction Sensor Card designed for Mark VI and EX2100 turbine excitation systems. It continuously monitors conduction states of exciter bridges, ensuring stable generator excitation and protection. Moreover, its compact PCB design allows seamless integration into industrial control racks while maintaining robust performance under harsh environments. This module is ideal for engineers seeking reliable excitation diagnostics and system safety.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMonitors conduction states of four exciter bridges (E1–E4) for accurate diagnostics.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProvides isolated logic outputs to the control system, enhancing signal integrity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompact and durable PCB construction enables easy installation in Mark VI and EX2100 racks.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWide operating temperature range (–30 °C to +65 °C) ensures continuous industrial operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOffers channel-to-channel isolation for safe and reliable system protection.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompatible with both EX2100 and EX2100e excitation systems for flexible application.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIS200EMCSG1AAB\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturer:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eGeneral Electric (GE)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSeries:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMark VI \/ EX2100 Excitation Control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eType:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eExciter Multibridge Conduction Sensor Card\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNumber of Sensors:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e4 (E1–E4)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eLogic signals to control system\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConnectors:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eSix-plug connectors for system integration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e–30 °C to +65 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWeight:\u003c\/strong\u003e 0.2kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIsolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eChannel-to-channel for safe operation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConstruction:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRobust PCB design for industrial durability\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInstruction Manual:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eGEZ-S2045\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRevision Quantity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e3\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTypical Applications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMonitoring turbine generator excitation systems for reliable operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProviding real-time diagnostic feedback for maintenance and protection systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIntegrating with Mark VI and EX2100 excitation control racks for industrial power generation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnsuring safe and efficient excitation bridge operation in large-scale energy facilities.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Is this sensor card compatible with all GE turbine excitation systems?\u003c\/strong\u003e\u003cbr\u003eA1: The IS200EMCSG1AAB is compatible with Mark VI, EX2100, and EX2100e excitation systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: What is the operating temperature range of this module?\u003c\/strong\u003e\u003cbr\u003eA2: It reliably operates between –30 °C and +65 °C, suitable for industrial environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: How many sensors are included on this card?\u003c\/strong\u003e\u003cbr\u003eA3: The card contains four conduction sensors (E1–E4) to monitor exciter bridges.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: Can this sensor card be used in new installations and retrofits?\u003c\/strong\u003e\u003cbr\u003eA4: Yes, it is suitable for both new system integration and replacement in existing setups.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":42594177613914,"sku":"IS200EMCSG1AAB","price":261.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/IS200EMCSG1AAB2.jpg?v=1764136163","url":"https:\/\/www.plcmasters.com\/products\/ge-is200emcsg1aab-exciter-multibridge-conduction-sensor-card","provider":"PLC Masters Ltd.","version":"1.0","type":"link"}