Skip to content
GE O2X1IS Intrinsically Safe Oxygen Transmitter

GE O2X1IS Intrinsically Safe Oxygen Transmitter

  • 1000 In stock
  • Manufacturer: GE Fanuc

  • Product No.: O2X1IS

  • Condition: In stock

  • Product Type: Intrinsically Safe Oxygen Transmitter

  • Product Origin: USA

  • Payment:T/T, Western Union

  • Weight: 600g

  • Shipping port: Xiamen

  • Warranty: 12 months

{"id":42602825973850,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"O2X1IS","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"GE O2X1IS Intrinsically Safe Oxygen Transmitter","public_title":null,"options":["Default Title"],"price":26100,"weight":600,"compare_at_price":56500,"inventory_management":"shopify","barcode":"USA","requires_selling_plan":false,"selling_plan_allocations":[],"quantity_rule":{"min":1,"max":null,"increment":1}}

Description

Product Description

The GE O2X1IS is an intrinsically safe oxygen transmitter designed for precise, continuous monitoring in industrial processes. It combines proven galvanic fuel cell technology with a compact, microprocessor‑based design, delivering reliable measurements in both parts per million (ppm) and percentage oxygen ranges. Moreover, its two‑wire, loop‑powered 4–20 mA output allows seamless integration into existing control systems. The transmitter is built for hazardous environments, ensuring operational safety without compromising accuracy or stability. Its low maintenance design extends sensor life and reduces downtime, making it an economical and dependable solution for industrial oxygen measurement.

Key Benefits

  • Intrinsically safe construction allows use in hazardous industrial environments without additional protective enclosures.

  • Flexible measurement ranges cover ppm and percent oxygen for diverse applications.

  • Reliable galvanic fuel cell technology ensures accurate, stable, and repeatable readings.

  • Compact and economical design minimizes installation space while supporting continuous monitoring.

  • Easy integration with standard 4–20 mA loop systems improves overall system efficiency.

Technical Specifications

  • Type: Intrinsically safe oxygen transmitter

  • Output: Two‑wire, loop‑powered 4–20 mA

  • Sensor Technology: Proven galvanic fuel cell O₂ sensor

  • Measurement Ranges:

    • Four ppm ranges: 10, 100, 1,000, 10,000 ppm

    • Three percent ranges: 1%, 10%, 25%

  • Accuracy: ±2% of full scale

  • Response Time: Standard, sensor dependent

  • Operating Temperature: 0 °C to +45 °C

  • Power Supply: 12–28 VDC loop power

  • Design: Compact, microprocessor‑based, continuous monitoring

  • Safety: Intrinsically safe for hazardous environments

  • Maintenance: Low maintenance, long sensor life

Typical Applications

  • Heat treating and bright annealing processes for quality control

  • Glove box leak detection in laboratory or production environments

  • Monitoring inert welding gases to ensure process safety

  • Hydrocarbon stream analysis in petrochemical plants

  • Ambient air oxygen monitoring in industrial facilities

Support & Maintenance

GE O2X1IS features long sensor life and low maintenance intervals, reducing operational downtime. The device supports easy calibration and offers robust microprocessor‑based diagnostics to maintain reliability. For instance, routine checks can extend sensor performance while minimizing unexpected failures.

FAQ

Q: Is the O2X1IS suitable for explosive environments?
A: Yes, the device is intrinsically safe and designed specifically for hazardous industrial areas.

Q: Can it measure both ppm and percent oxygen?
A: Absolutely. The O2X1IS provides flexible measurement ranges for ppm and percent oxygen levels.

Q: How does it integrate with control systems?
A: It features a two‑wire 4–20 mA loop output, allowing seamless connection to standard control systems.

Q: What is the expected maintenance interval?
A: The device is low maintenance, and sensor life is long, reducing the need for frequent servicing.

Q: What temperature range can it operate in?
A: It operates reliably between 0 °C and +45 °C under standard conditions.

Features

We welcome bulk orders and have a minimum order quantity of just one unit.

Upon request, we can provide all necessary documentation, including Certificates of Origin/Conformance and other required export documents.

For items in stock, we aim to deliver within 1-3 days after payment confirmation. Items with specified lead times will be delivered according to the quoted schedule.

We accept 100% T/T (Telegraphic Transfer) payment before shipping. For items with lead times, a 30% deposit is required upfront, with the remaining 70% due before shipment. For RMB transfers, please contact us if you have an agent in China.

We offer a standard one-year warranty on all new and original items. If you require an extended warranty, please contact us for additional cost details.

Your satisfaction is important to us. If you need to return an item, it must be done within 30 days of the order date. The product must be unused, unopened, and in its original packaging with all accessories included. Refunds are processed within 5-7 business days after we receive the returned item. Please note that shipping and related charges are non-refundable.

Featured

Complementary products