Skip to content
Honeywell 51109620-200 TDC 3000 I/O Link Cable Assembly

Honeywell 51109620-200 TDC 3000 I/O Link Cable Assembly

  • 1000 In stock
  • Manufacturer: HONEYWELL

  • Product No.: 51109620-200

  • Condition: In stock

  • Product Type: TDC 3000 I/O Link Cable Assembly

  • Product Origin: USA

  • Payment:T/T, Western Union

  • Weight: 227g

  • Shipping port: Xiamen

  • Warranty: 12 months

{"id":42910158422106,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"51109620-200","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Honeywell 51109620-200 TDC 3000 I\/O Link Cable Assembly","public_title":null,"options":["Default Title"],"price":20900,"weight":227,"compare_at_price":45000,"inventory_management":"shopify","barcode":"USA","requires_selling_plan":false,"selling_plan_allocations":[],"quantity_rule":{"min":1,"max":null,"increment":1}}

Description


Configured for I/O signal interconnection in Honeywell TDC 3000 and TPS systems, the Honeywell 51109620-200 (51109620-200 I/O Link Cable Assembly) provides direct electrical connection between I/O modules and IOTA/IOM termination assemblies. It uses a multi-conductor cable structure with full EMI/RFI shielding and keyed locking connectors.

Hardware Specifications

Parameter Specification
Model 51109620-200
Brand Honeywell
Product Type I/O Link Cable Assembly
System Compatibility Honeywell TDC 3000, TPS, and related DCS platforms
Function I/O module to IOTA/IOM termination assembly connection
Signal Type Low-voltage digital and analog I/O communication
Cable Construction Multi-conductor industrial-grade cable
Shielding Full EMI/RFI shielding
Connector Type Honeywell-specific keyed connectors
Connector Retention Locking mechanism
Cable Length Fixed-length version; exact length not specified in supplied data
Installation Environment Industrial control enclosures
Operating Temp Suitable for typical DCS cabinet temperature ranges; exact range not specified
Vibration Resistance Stated as compliant with Honeywell industrial standards

DCS I/O Signal and Shielding Characteristics

The 51109620-200 provides the physical signal path between Honeywell I/O modules and IOTA/IOM termination assemblies. The cable carries low-voltage digital and analog I/O communication rather than performing signal conditioning or active protocol processing.

The supplied data specifies full EMI/RFI shielding. In a cabinet installation, the shield should be routed and terminated according to the applicable Honeywell wiring and grounding documentation. Signal cables should be separated from high-current power conductors and other major interference sources where the cabinet design permits.

The keyed connectors provide defined mating orientation, while the locking mechanism maintains connector engagement after installation. The cable assembly itself has no stated independent power consumption.

Frequently Asked Questions

Q: Does the 51109620-200 require an external power supply?

A: No. The 51109620-200 is a passive I/O Link Cable Assembly. It does not contain an active power-consuming circuit.

Q: What equipment does the cable connect?

A: It connects Honeywell I/O modules with IOTA/IOM termination assemblies in compatible TDC 3000 and TPS configurations. Compatibility should be checked against the specific I/O module and termination assembly.

Q: Is the cable suitable for cabinet wiring with electromagnetic interference?

A: The supplied data specifies full EMI/RFI shielding. Installation should still maintain appropriate separation from power and other high-interference conductors, with shield termination following the applicable system wiring requirements.

Field Installation Guidelines

Verify the cable part number and connector keying against the target I/O module and IOTA/IOM termination assembly before installation.

Route the cable without excessive bending, crushing, or mechanical tension. Keep the cable separated from high-current power wiring and switching conductors where practical.

Inspect both connectors for mechanical damage or contamination before mating. Align the keyed connector correctly and engage the locking mechanism fully.

Terminate and bond the cable shield according to the applicable Honeywell cabinet grounding and system wiring documentation. Do not introduce an undocumented shield connection that could create an unintended ground path.

After installation, verify connector engagement and cable routing before energizing the associated control cabinet.

Features

We welcome bulk orders and have a minimum order quantity of just one unit.

Upon request, we can provide all necessary documentation, including Certificates of Origin/Conformance and other required export documents.

For items in stock, we aim to deliver within 1-3 days after payment confirmation. Items with specified lead times will be delivered according to the quoted schedule.

We accept 100% T/T (Telegraphic Transfer) payment before shipping. For items with lead times, a 30% deposit is required upfront, with the remaining 70% due before shipment. For RMB transfers, please contact us if you have an agent in China.

We offer a standard one-year warranty on all new and original items. If you require an extended warranty, please contact us for additional cost details.

Your satisfaction is important to us. If you need to return an item, it must be done within 30 days of the order date. The product must be unused, unopened, and in its original packaging with all accessories included. Refunds are processed within 5-7 business days after we receive the returned item. Please note that shipping and related charges are non-refundable.

Featured

Complementary products