{"product_id":"honeywell-51196653-100-tdc-3000-five-slot-file-power-supply-module","title":"Honeywell 51196653-100 TDC 3000 Five-Slot File Power Supply Module","description":"\u003cp\u003eThe \u003cstrong\u003eHoneywell 51196653-100\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e51196653-100\u003c\/strong\u003e Five-Slot File Power Supply Module, operates as a dedicated hardware component for regulated DC power distribution within Honeywell TDC 3000 Local Control Network (LCN) chassis architectures.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e51196653-100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e8.27 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eInput: approx. 6 A at 120 VAC \/ 3 A at 240 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eFive-Slot File Power Supply Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Platform\u003c\/td\u003e\n\u003ctd\u003eHoneywell TDC 3000 LCN Series\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Voltage\u003c\/td\u003e\n\u003ctd\u003e102-264 VAC auto-ranging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Frequency\u003c\/td\u003e\n\u003ctd\u003e47-63 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e+5 VDC at 30 A; +12 VDC at 10 A; -12 VDC at 1 A; +27 VDC at 1.2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003eStandard 3-pin edge connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClocking Function\u003c\/td\u003e\n\u003ctd\u003eINT\/EXT jumper selectable clock source for SOE synchronization\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Control\u003c\/td\u003e\n\u003ctd\u003eVariable fan control based on ambient temperature and +5 VDC load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertification\u003c\/td\u003e\n\u003ctd\u003eCE compliant, EIA-413\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eHoneywell TDC 3000 LCN Power Distribution and Synchronization\u003c\/h3\u003e\n\u003cp\u003eThe 51196653-100 provides multi-voltage DC output rails for a five-slot TDC 3000 file assembly. The module converts incoming AC power into regulated DC supplies required by chassis-mounted control hardware. The onboard clock selection jumper supports internal line frequency timing or external Sequence of Events (SOE) synchronization input.\u003c\/p\u003e\n\u003cp\u003eThe power module incorporates active Power Factor Correction (PFC) and controlled cooling operation. Fan speed adjustment follows ambient conditions and +5 VDC loading to regulate internal thermal conditions while maintaining power output stability.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What DC output rails are provided by the Honeywell 51196653-100?\u003cbr\u003eA: The module provides +5 VDC, +12 VDC, -12 VDC, and +27 VDC output rails for the TDC 3000 five-slot file power architecture.\u003c\/p\u003e\n\u003cp\u003eQ: Can the 51196653-100 support SOE clock synchronization?\u003cbr\u003eA: Yes. The module includes an INT\/EXT jumper selection for internal line frequency clocking or external SOE clock synchronization.\u003c\/p\u003e\n\u003cp\u003eQ: Does the module use the same connector format as older chassis versions?\u003cbr\u003eA: The standard version uses a 3-pin edge connector. Older 8-pin chassis configurations require an adapter cable for connection.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the 51196653-100 in the designated five-slot file power supply position within the TDC 3000 LCN chassis assembly.\u003c\/p\u003e\n\u003cp\u003eVerify AC input wiring matches the specified auto-ranging input range before energizing the module. Maintain separation between AC power wiring and low-level signal wiring to reduce electrical interference.\u003c\/p\u003e\n\u003cp\u003eConnect the chassis grounding system according to the control cabinet grounding practice. Ensure connector contacts are clean and fully seated before operation.\u003c\/p\u003e\n\u003cp\u003eFor SOE synchronization applications, verify the INT\/EXT clock jumper position matches the required timing source. Confirm that installed modules operate within the chassis power loading limits before system startup.\u003c\/p\u003e","brand":"HoneyWell","offers":[{"title":"Default Title","offer_id":41447087243354,"sku":"51196653-100","price":208.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/51196653-1002.jpg?v=1789720458","url":"https:\/\/www.plcmasters.com\/products\/honeywell-51196653-100-tdc-3000-five-slot-file-power-supply-module","provider":"PLC Masters Ltd.","version":"1.0","type":"link"}