{"product_id":"honeywell-51304481-100-low-level-analog-input-iop-module","title":"Honeywell 51304481-100 Low-Level Analog Input IOP Module","description":"\u003cp\u003eThe Honeywell 51304481-100, also cataloged as the 51304481-100 Low-Level Analog Input IOP Module, acquires analog voltage and current signals for industrial control system input processing. It supports 8 analog input channels, selectable input ranges of 0-10 V and 0-20 mA, and 16-bit resolution. The supplied specifications list a sampling rate of up to 10 kHz and channel isolation for electrical signal separation.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e51304481-100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Type\u003c\/td\u003e\n\u003ctd\u003eLow-Level Analog Input IOP Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Channels\u003c\/td\u003e\n\u003ctd\u003e8 analog input channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Range\u003c\/td\u003e\n\u003ctd\u003e0-10 V or 0-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e16 bits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSampling Rate\u003c\/td\u003e\n\u003ctd\u003eUp to 10 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolation\u003c\/td\u003e\n\u003ctd\u003eSupported; isolation rating not specified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-40 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e112 x 90 x 60 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.00 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eAnalog Signal Acquisition and Isolation\u003c\/h3\u003e\n\u003cp\u003eThe 51304481-100 accepts voltage or current signals within the specified input ranges. Its 16-bit resolution defines the nominal digital conversion granularity, while the stated sampling rate of up to 10 kHz describes the maximum sampling capability reported in the supplied data. Actual measurement accuracy, input impedance, and channel-to-channel isolation ratings require confirmation from the applicable hardware documentation.\u003c\/p\u003e\n\u003cp\u003eFor installation, voltage and current input wiring must follow the configured channel mode. Signal cable routing should minimize coupling from drive outputs, contactors, and other sources of electrical interference. Cable shields should be terminated according to the control system grounding design.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: How many analog input channels does the 51304481-100 provide?\u003c\/p\u003e\n\u003cp\u003eA: The supplied specifications identify 8 analog input channels supporting 0-10 V or 0-20 mA signals.\u003c\/p\u003e\n\u003cp\u003eQ: What is the module's resolution and maximum sampling rate?\u003c\/p\u003e\n\u003cp\u003eA: The supplied data specifies 16-bit resolution and a sampling rate of up to 10 kHz. The per-channel sampling behavior should be verified against the manufacturer's technical manual.\u003c\/p\u003e\n\u003cp\u003eQ: Can the module be hot-swapped while the system is energized?\u003c\/p\u003e\n\u003cp\u003eA: Hot-swap capability is not confirmed by the supplied information. Verify the applicable I\/O chassis instructions and system maintenance procedures before removing or inserting the module.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eVerify the module part number and compatibility with the installed Honeywell I\/O subsystem before installation.\u003c\/li\u003e\n\u003cli\u003eConfirm the configured input type and range for each channel before connecting field signals.\u003c\/li\u003e\n\u003cli\u003eCheck terminal assignments and field wiring polarity against the manufacturer's wiring documentation.\u003c\/li\u003e\n\u003cli\u003eRoute low-level analog signal cables separately from high-current power wiring and switching circuits.\u003c\/li\u003e\n\u003cli\u003eApply cable shielding and grounding according to the system's grounding design to limit electromagnetic interference.\u003c\/li\u003e\n\u003cli\u003eConfirm that cabinet ambient temperature remains within the specified -40 to +70 deg C range.\u003c\/li\u003e\n\u003cli\u003eVerify channel readings and signal scaling during commissioning before enabling dependent control logic.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"HoneyWell","offers":[{"title":"Default Title","offer_id":41792805929050,"sku":"51304481-100","price":152.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/Honeywell51304481-100.jpg?v=1742291440","url":"https:\/\/www.plcmasters.com\/products\/honeywell-51304481-100-low-level-analog-input-iop-module","provider":"PLC Masters Ltd.","version":"1.0","type":"link"}