Skip to content
Honeywell 51304481-150 MC-PAIL02 Low-Level Analog Input Module

Honeywell 51304481-150 MC-PAIL02 Low-Level Analog Input Module

  • 12 In stock
  • Manufacturer: HoneyWell

  • Product No.: 51304481-150

  • Condition: In stock

  • Product Type: Low-Level Analog Input Module

  • Product Origin: USA

  • Payment:T/T, Western Union

  • Weight: 440g

  • Shipping port: Xiamen

  • Warranty: 12 months

{"id":41686222864474,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"51304481-150","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Honeywell 51304481-150 MC-PAIL02 Low-Level Analog Input Module","public_title":null,"options":["Default Title"],"price":10800,"weight":440,"compare_at_price":45600,"inventory_management":"shopify","barcode":"USA","requires_selling_plan":false,"selling_plan_allocations":[],"quantity_rule":{"min":1,"max":null,"increment":1}}

Description

The Honeywell 51304481-150, also cataloged as the MC-PAIL02 Low-Level Analog Input (LLAI) Module, acquires differential analog signals and converts them into digital values for process control systems. The module provides 8 analog input channels with a specified input range of -10 V to +10 V and 16-bit resolution. Its I/O processor (IOP) assemblies are conformally coated to provide protection against humidity and most chemical gases.

Hardware Specifications

Parameter Specification
Model 51304481-150
Base Model MC-PAIL02
Brand Honeywell
Product Type Low-Level Analog Input Module
Description Low-Level Analog Input (LLAI)
Number of Inputs 8 analog inputs
Input Configuration Differential
Input Voltage Range -10 V to +10 V
Resolution 16-bit (source-listed)
Sampling Rate Up to 100 kHz (source-listed; confirm module documentation)
Power Supply 24 VDC (source-listed; confirm module requirements)
IOP Protection Conformally coated
CE Compliance CE-compliant part number: 51304481-150
Weight 0.44 kg
Dimensions 305 x 89 x 30 mm

Differential Signal Acquisition and IOP Protection

The MC-PAIL02 is an 8-channel low-level analog input module with differential signal inputs. The specified bipolar input range extends from -10 V to +10 V, with a listed 16-bit resolution. Differential acquisition measures the voltage difference between the input terminals, allowing the receiving channel to distinguish the intended signal from voltage components common to both inputs, subject to the module's electrical limits.

The associated I/O processor assemblies are conformally coated. This thin protective polymer layer helps limit exposure-related damage from humidity and many chemical gases. Coating does not establish an ingress protection rating or make the assembly suitable for unrestricted chemical exposure.

Frequently Asked Questions

Q: How many analog input channels does the 51304481-150 provide?

A: The supplied specifications identify 8 differential analog input channels.

Q: What input voltage range is specified for the MC-PAIL02?

A: The supplied data lists -10 V to +10 V. Verify the permitted common-mode voltage, overvoltage limits, and wiring requirements in the applicable Honeywell hardware documentation before connecting field signals.

Q: What is the function of the conformal coating on the IOP assemblies?

A: The coating provides a thin protective layer intended to resist the effects of humidity and most chemical gases. It does not replace correct enclosure selection, environmental assessment, or installation practices.

Field Installation Guidelines

  • Verify the module model, part number, and compatibility with the installed Honeywell I/O chassis and control system before installation.
  • Confirm the module's power supply requirements and chassis loading against the manufacturer's hardware documentation.
  • Identify differential input terminal assignments from the applicable wiring diagram before connecting field devices.
  • Route low-level analog signal cables separately from high-current power wiring, contactor circuits, and variable-frequency drive cables to reduce electrical interference.
  • Apply cable shielding and grounding according to the Honeywell installation manual and the plant grounding design. Avoid unintended ground loops.
  • Check field signal polarity, input voltage limits, and common-mode voltage compatibility before energizing the circuit.
  • Inspect terminal connections and verify signal values during commissioning.
  • Do not assume hot-swap capability, channel isolation, or a specific operating temperature range without confirmation from the applicable hardware manual.

Features

We welcome bulk orders and have a minimum order quantity of just one unit.

Upon request, we can provide all necessary documentation, including Certificates of Origin/Conformance and other required export documents.

For items in stock, we aim to deliver within 1-3 days after payment confirmation. Items with specified lead times will be delivered according to the quoted schedule.

We accept 100% T/T (Telegraphic Transfer) payment before shipping. For items with lead times, a 30% deposit is required upfront, with the remaining 70% due before shipment. For RMB transfers, please contact us if you have an agent in China.

We offer a standard one-year warranty on all new and original items. If you require an extended warranty, please contact us for additional cost details.

Your satisfaction is important to us. If you need to return an item, it must be done within 30 days of the order date. The product must be unused, unopened, and in its original packaging with all accessories included. Refunds are processed within 5-7 business days after we receive the returned item. Please note that shipping and related charges are non-refundable.