{"product_id":"honeywell-51304544-100-klcn-i-o-cb-card","title":"Honeywell 51304544-100 KLCN I\/O CB Card","description":"\u003cp\u003eThe \u003cstrong\u003eHoneywell 51304544-100\u003c\/strong\u003e, also cataloged as the \u003cstrong\u003e51304544-100\u003c\/strong\u003e KLCN I\/O CB Card, is an input\/output board for the Honeywell TDC 3000 Distributed Control System (DCS). It processes input\/output signals associated with field devices and supports signal exchange between the field interface and the control system.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e51304544-100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eKLCN I\/O CB Card\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eHoneywell TDC 3000 DCS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003eInput\/output signal processing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.31 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e2.5 x 14 x 17.8 cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTDC 3000 I\/O Signal Interface\u003c\/h3\u003e\n\u003cp\u003eThe 51304544-100 is identified as a KLCN I\/O CB Card for the Honeywell TDC 3000 platform. Its documented function is to process input\/output signals associated with field devices. Installation compatibility must be verified against the applicable TDC 3000 hardware configuration, board location, and system documentation. Specific channel counts, electrical signal ranges, and backplane current requirements are not provided in the available specifications.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Which control system is compatible with the Honeywell 51304544-100?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The card is specified for Honeywell TDC 3000 DCS systems. Confirm the required hardware revision and installation position against the system documentation before replacement.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What are the physical dimensions and weight of this card?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The listed dimensions are 2.5 x 14 x 17.8 cm, and the listed weight is 0.31 lbs (approximately 0.14 kg).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What electrical parameters must be checked before installation?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Verify the required supply and backplane connections, board orientation, connector condition, and compatibility with the installed I\/O configuration. The available specifications do not state power consumption, operating temperature, or individual channel electrical ratings.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eConfirm that the installed rack or subsystem supports the 51304544-100 KLCN I\/O CB Card.\u003c\/li\u003e\n\u003cli\u003eFollow the site-approved shutdown and isolation procedure before removing or inserting the board.\u003c\/li\u003e\n\u003cli\u003eInspect the board edge connectors and mating backplane connectors for contamination, damage, or bent contacts.\u003c\/li\u003e\n\u003cli\u003eAlign the board with the designated guides and connector position before insertion. Do not force the board into the backplane.\u003c\/li\u003e\n\u003cli\u003eKeep field wiring separated from power conductors and other sources of electrical interference according to the installation design.\u003c\/li\u003e\n\u003cli\u003eApply shield termination and grounding practices specified by the TDC 3000 system documentation and the connected field-device requirements.\u003c\/li\u003e\n\u003cli\u003eAfter installation, verify board recognition, system diagnostics, and the associated input\/output signal behavior before returning the subsystem to service.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"HoneyWell","offers":[{"title":"Default Title","offer_id":41801948921946,"sku":"51304544-100","price":162.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/Honeywell51304544-100.jpg?v=1742546435","url":"https:\/\/www.plcmasters.com\/products\/honeywell-51304544-100-klcn-i-o-cb-card","provider":"PLC Masters Ltd.","version":"1.0","type":"link"}