{"product_id":"honeywell-51304672-100-analog-output-iop-module","title":"Honeywell 51304672-100 Analog Output IOP Module","description":"\u003cp\u003eThe \u003cstrong\u003eHoneywell 51304672-100\u003c\/strong\u003e is an Analog Output Input\/Output Processor (AO IOP) card, identified as model MU-PAOX03 in Honeywell's Process Manager I\/O hardware documentation. It provides the analog output function within the control system I\/O architecture, transferring controller output commands to field-side analog signal circuits. This part number identifies the non-CE-compliant version of the MU-PAOX03 card.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003e51304672-100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIOP Model\u003c\/td\u003e\n\u003ctd\u003eMU-PAOX03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eAnalog Output IOP Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Function\u003c\/td\u003e\n\u003ctd\u003eAnalog Output (AO)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Channels\u003c\/td\u003e\n\u003ctd\u003e8 (as stated in supplied product information)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eProcess Manager (PM), Advanced Process Manager (APM), High-Performance Process Manager (HPM)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCE Compliance\u003c\/td\u003e\n\u003ctd\u003eNon-CE-compliant version\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConformal Coating\u003c\/td\u003e\n\u003ctd\u003eWithout conformal coating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.8 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e\u003cstrong\u003eAnalog Output Function\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe MU-PAOX03 performs the analog output role in the Honeywell I\/O architecture. The controller generates output commands based on its control strategy, and the analog output card handles the corresponding field-side output signals. These signals can be used by compatible final control elements when the electrical signal type and field termination configuration match the application.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eOutput Signal Characteristics\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe module provides \u003cstrong\u003eeight 4-20 mA analog output channels\u003c\/strong\u003e. Each channel converts a digital controller command into a corresponding current-loop signal for field devices such as control valve positioners and other analog-controlled equipment.\u003c\/p\u003e\n\u003cp\u003eThe 4-20 mA range supports continuous control signaling, with 4 mA representing the lower end of the standard operating range and 20 mA representing the upper end. The eight-channel configuration allows multiple independent control outputs to be handled by one IOP card.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eHardware Identification and Configuration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eHoneywell documentation identifies 51304672-100 as the \u003cstrong\u003eMU-PAOX03 Analog Output IOP\u003c\/strong\u003e. The MU designation identifies the uncoated hardware execution, while this particular part number is listed as the non-CE-compliant version.\u003c\/p\u003e\n\u003cp\u003eThe CE-compliant version is separately identified in Honeywell's hardware planning documentation. These execution differences should be checked when selecting a replacement for an existing installation.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What is the difference between MU-PAOX03 and MU-PAOY22?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: MU-PAOX03 provides 8 analog output channels, while MU-PAOY22 provides 16 channels. They have different channel capacities and should not be treated as direct substitutes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the 51304672-100 support 4-20 mA output signals?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Yes. The MU-PAOX03 supports eight 4-20 mA analog output channels for continuous field control signals.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What should be checked when replacing this module?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Verify the MU-PAOX03 model, CE compliance status, conformal coating execution, installed FTA and field wiring configuration. The replacement must match the requirements of the existing Process Manager I\/O installation.\u003c\/p\u003e","brand":"HoneyWell","offers":[{"title":"Default Title","offer_id":41713925292122,"sku":"51304672-100","price":146.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/Honeywell51304672-100.jpg?v=1740996832","url":"https:\/\/www.plcmasters.com\/products\/honeywell-51304672-100-analog-output-iop-module","provider":"PLC Masters Ltd.","version":"1.0","type":"link"}