{"id":42062392393818,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"51305072-100","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Honeywell 51305072-100 CLCN A\/B Local Control Network I\/O Board","public_title":null,"options":["Default Title"],"price":24600,"weight":195,"compare_at_price":45600,"inventory_management":"shopify","barcode":"USA","requires_selling_plan":false,"selling_plan_allocations":[],"quantity_rule":{"min":1,"max":null,"increment":1}}

Description

The Honeywell 51305072-100 is a CLCN A/B Local Control Network (LCN) I/O board designed for Honeywell TDC 3000 five-slot and ten-slot chassis systems. It provides connections for both LCN A and LCN B communication cables and establishes the node address within the network. The board features a tall faceplate and a CE-compliant CLCN interface configuration.

Functional Description

The 51305072-100 serves as the LCN interface board for a TDC 3000 system node. Its two network connections provide interfaces to LCN A and LCN B, which form the dual communication paths of the LCN architecture.

Both connections allow the node to participate in the LCN communication network. The board also provides the hardware arrangement for assigning the node address, which identifies the module within the network topology.

Technical Specifications

Parameter Specification
Model 51305072-100
Brand Honeywell
Product Type CLCN A/B Local Control Network I/O Board
Board Type CLCN I/O
System Compatibility Honeywell TDC 3000
Chassis Compatibility 5-slot and 10-slot chassis
Network Interface LCN A and LCN B
Cable Connections LCN A and LCN B
Node Address Configuration Address pack / jumpers
Faceplate Tall faceplate
Compliance CE compliant

LCN A/B Communication and Node Addressing

The board connects the TDC 3000 node to both LCN communication paths. LCN A and LCN B are separate network connections, and their correct identification and routing are important when maintaining the system communication topology.

Node addressing must correspond to the board's assigned position in the LCN network. When replacing the board or adding a node, the address configuration should be checked against the existing network address plan to avoid duplicate node assignments.

Installation and Configuration Considerations

  • Confirm that the chassis uses a compatible five-slot or ten-slot configuration.
  • Verify that both LCN A and LCN B cables are connected to their designated interfaces.
  • Check the node address configuration before commissioning a replacement board.
  • Confirm the tall faceplate and board configuration against the installed hardware.

Frequently Asked Questions

Q: What is the main function of the Honeywell 51305072-100?

A: It provides the CLCN A/B interface for a TDC 3000 node, connecting the node to the LCN A and LCN B communication cables and providing node address configuration.

Q: Can the 51305072-100 be used in both five-slot and ten-slot chassis?

A: Yes. The board is identified for both Honeywell five-slot and ten-slot chassis configurations. The physical slot arrangement and associated system hardware should still be checked before replacement.

Q: What should be checked when replacing a 51305072-100?

A: Verify the complete part number, CLCN A/B board type, faceplate configuration, cable connections, and assigned LCN node address. The replacement address must match the intended network node assignment.

Features

We welcome bulk orders and have a minimum order quantity of just one unit.

Upon request, we can provide all necessary documentation, including Certificates of Origin/Conformance and other required export documents.

For items in stock, we aim to deliver within 1-3 days after payment confirmation. Items with specified lead times will be delivered according to the quoted schedule.

We accept 100% T/T (Telegraphic Transfer) payment before shipping. For items with lead times, a 30% deposit is required upfront, with the remaining 70% due before shipment. For RMB transfers, please contact us if you have an agent in China.

We offer a standard one-year warranty on all new and original items. If you require an extended warranty, please contact us for additional cost details.

Your satisfaction is important to us. If you need to return an item, it must be done within 30 days of the order date. The product must be unused, unopened, and in its original packaging with all accessories included. Refunds are processed within 5-7 business days after we receive the returned item. Please note that shipping and related charges are non-refundable.

Featured

Complementary products