{"id":42608948150362,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"FC-TSGAS-1624","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Honeywell FC-TSGAS-1624 Field Termination Assembly","public_title":null,"options":["Default Title"],"price":20900,"weight":520,"compare_at_price":45000,"inventory_management":"shopify","barcode":"USA","requires_selling_plan":false,"selling_plan_allocations":[],"quantity_rule":{"min":1,"max":null,"increment":1}}

Description

The Honeywell FC-TSGAS-1624 is a field termination assembly (FTA) for gas and flame detector signal connections in the Honeywell Safety Manager system. It provides 16 analog input channels for 0-20 mA signals and interfaces field detector wiring with the SAI-1620m high-density analog input module. Its termination circuitry supports signal conditioning and field power distribution.

Function and Signal Interface

The FC-TSGAS-1624 provides the connection point between field-mounted gas or flame detectors and the Safety Manager analog input system. Each input channel receives a detector current signal and converts it into a voltage signal for acquisition by the SAI-1620m module.

The 16 channels share a common 0 V reference. The assembly also provides fused power distribution to the connected transmitters, with individual channel protection specified in the hardware documentation.

Analog Input Conversion

Each channel uses a precision 500 ohm resistor to convert the detector current into a voltage signal for the SAI-1620m. The conversion range at the FTA output is 0-4 V DC, with a specified accuracy of 0.1%.

The assembly supports both active and passive transmitter wiring arrangements. Individual field cable shield terminals provide separate termination points for analog input cable screening.

Power Distribution and Protection

The FC-TSGAS-1624 uses an external 24 V DC supply connected through screw terminals A and B. It distributes power to the field transmitters through individual 500 mAT fused circuits. The external supply voltage can also be monitored by the Safety Manager through the SAI-1620m.

Parameter Specifications

Parameter Specification
Model FC-TSGAS-1624
Brand Honeywell
Product Type Gas / Flame Detector Field Termination Assembly
System Honeywell Safety Manager
Number of Input Channels 16
Input Signal 0-20 mA
Input Current Range 0-25 mA
Input Resistance 500 ohm (+/- 5%)
Common Reference Common 0 V
External Power Supply 24 V DC
Current Consumption 3 mA (without field loads)
Output to SAI-1620m 0-4 V DC
Output Accuracy 0.1%
Channel Fuse Rating 500 mAT
Fuse Dimensions 5 x 20 mm
System Interconnection SICC-0001/Lx
Compatible Analog Input Module SAI-1620m
Approvals CE, TUV, UL, CSA, FM
Mounting TS32 / TS35 x 7.5 DIN rail
Module Dimensions 225 x 70 x 60 mm
Used DIN Rail Length 226 mm
Weight 0.52 kg 

Wiring and Installation Requirements

The assembly provides 16 groups of four screw terminals, numbered 1 to 64. Each channel has a dedicated field cable shield connection.

The manufacturer's hardware reference specifies the following termination requirements:

  • Standard signal terminals: maximum wire size 2.5 mm2 (AWG 14).
  • Signal terminal strip length: 7 mm.
  • Signal terminal tightening torque: 0.5 Nm.
  • Power terminals A and B: maximum wire size 16 mm2 (AWG 8).
  • Power terminal strip length: 7 mm.
  • Power terminal tightening torque: 1.2 Nm.

The external supply's 0 V connection is directly connected to the common 0 V reference of all 16 analog inputs. This relationship should be considered when checking field wiring and grounding arrangements.

Frequently Asked Questions

Q: Which analog input module is compatible with the FC-TSGAS-1624?

A: The specified companion module is the Honeywell SAI-1620m safe high-density analog input module. The FTA transfers its 16 input signals through the SICC-0001/Lx system interconnection cable.

Q: Does the FC-TSGAS-1624 support both active and passive gas detector connections?

A: Yes. The manufacturer's connection diagrams document both three-wire gas/flame detectors and two-wire 0(4)-20 mA transmitters. The appropriate wiring arrangement must match the field transmitter configuration.

Q: Does the FC-TSGAS-1624 provide individual channel protection?

A: Yes. Each transmitter power supply circuit has a 500 mAT fuse. The fuse rating is subject to temperature derating, reaching 0.35 A at a module ambient temperature of 70 deg C according to the manufacturer's specification.

Features

We welcome bulk orders and have a minimum order quantity of just one unit.

Upon request, we can provide all necessary documentation, including Certificates of Origin/Conformance and other required export documents.

For items in stock, we aim to deliver within 1-3 days after payment confirmation. Items with specified lead times will be delivered according to the quoted schedule.

We accept 100% T/T (Telegraphic Transfer) payment before shipping. For items with lead times, a 30% deposit is required upfront, with the remaining 70% due before shipment. For RMB transfers, please contact us if you have an agent in China.

We offer a standard one-year warranty on all new and original items. If you require an extended warranty, please contact us for additional cost details.

Your satisfaction is important to us. If you need to return an item, it must be done within 30 days of the order date. The product must be unused, unopened, and in its original packaging with all accessories included. Refunds are processed within 5-7 business days after we receive the returned item. Please note that shipping and related charges are non-refundable.

Featured

Complementary products