{"id":67973320081498,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"FS-TRO-1024","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Honeywell FS-TRO-1024 Relay Output Field Termination Assembly","public_title":null,"options":["Default Title"],"price":18200,"weight":500,"compare_at_price":40000,"inventory_management":"shopify","barcode":null,"requires_selling_plan":false,"selling_plan_allocations":[],"quantity_rule":{"min":1,"max":null,"increment":1}}

Description

The Honeywell FS-TRO-1024 is a 10-channel digital output Field Termination Assembly (FTA) designed for relay-contact signal wiring in Honeywell safety control systems. It provides the field wiring interface between the system interconnection cable and external circuits through screw terminals. The assembly supports DIN rail mounting and connects to compatible relay output modules through the specified interconnection cable.

Function and System Interface

The FS-TRO-1024 serves as a field termination point rather than a standalone relay output controller. It connects the system interconnection cable SIC-C-12 to external field wiring, allowing relay contact signals from compatible output modules to reach field devices.

The documented configuration supports ten output channels from a redundant pair of 10208/2/1 modules. This distinction is important when selecting replacement hardware: the FTA provides the termination and wiring interface, while the associated output modules perform the relay switching.

Relay Contact and Electrical Ratings

The FTA carries ten relay-contact circuits associated with the 10208/2/1 relay output modules. These are potential-free contact outputs, meaning the field circuit uses the relay contacts rather than receiving a generated 24 VDC output supply from the FTA.

The documented electrical limits include a maximum continuous current of 2 A per channel and maximum switched power of 100 W / 1000 VA. The contact material on the associated 10208/2/1 relay module is gold flash over silver-cadmium oxide.

Installation and Field Wiring

The FS-TRO-1024 uses a universal snap-in mounting arrangement for standard TS32 and TS35 x 7.5 DIN rails. External wiring connects through screw terminals, while the system-side connection uses the SIC-C-12 interconnection cable.

The specified terminal requirements are:

  • Maximum wire diameter: 2.5 mm (AWG 14)
  • Wire stripping length: 7 mm (0.28 in)
  • Terminal tightening torque: 0.5 Nm (0.37 ft-lb)

Technical Specifications

Parameter Specification
Model FS-TRO-1024
Brand Honeywell
Product Type Digital Output Relay Contact FTA
Number of Channels 10
Output Type Relay contacts
Associated Output Module 10208/2/1
System Interconnection Cable SIC-C-12
Maximum Continuous Current 2 A per channel
Maximum Voltage 36 VAC / 50 VDC
Maximum Switched Power 100 W / 1000 VA
Contact Material Gold flash over silver-cadmium oxide (10208/2/1)
Mounting TS32 / TS35 x 7.5 DIN rail
Module Dimensions 60 x 70 x 54 mm (L x W x H)
Used Rail Length 61 mm
Maximum Wire Diameter 2.5 mm (AWG 14)
Wire Stripping Length 7 mm (0.28 in)
Terminal Tightening Torque 0.5 Nm (0.37 ft-lb)

Frequently Asked Questions

Q: Is the FS-TRO-1024 a standalone relay output module?

A: No. It is a Field Termination Assembly (FTA). It provides the field wiring interface for compatible 10208/2/1 relay output modules through the SIC-C-12 cable.

Q: How many relay output channels can the FS-TRO-1024 terminate?

A: It supports ten relay-contact channels. The documented configuration allows connection of the ten channels from a single 10208/2/1 module or a redundant pair of these modules.

Q: What should be checked before replacing an FS-TRO-1024?

A: Verify the ten-channel configuration, SIC-C-12 cable connection, associated 10208/2/1 output modules, DIN rail arrangement and terminal wiring requirements. The FTA should not be substituted directly with FS-RO-1024, which is a different relay output module.

Features

We welcome bulk orders and have a minimum order quantity of just one unit.

Upon request, we can provide all necessary documentation, including Certificates of Origin/Conformance and other required export documents.

For items in stock, we aim to deliver within 1-3 days after payment confirmation. Items with specified lead times will be delivered according to the quoted schedule.

We accept 100% T/T (Telegraphic Transfer) payment before shipping. For items with lead times, a 30% deposit is required upfront, with the remaining 70% due before shipment. For RMB transfers, please contact us if you have an agent in China.

We offer a standard one-year warranty on all new and original items. If you require an extended warranty, please contact us for additional cost details.

Your satisfaction is important to us. If you need to return an item, it must be done within 30 days of the order date. The product must be unused, unopened, and in its original packaging with all accessories included. Refunds are processed within 5-7 business days after we receive the returned item. Please note that shipping and related charges are non-refundable.

Featured

Complementary products