{"product_id":"honeywell-fs-tsgas-1624-fail-safe-gas-flame-detector-input-fta","title":"Honeywell FS-TSGAS-1624 Fail-Safe Gas-Flame Detector Input FTA","description":"\u003cp\u003eThe \u003cstrong\u003eHoneywell FS-TSGAS-1624\u003c\/strong\u003e is a Fail-Safe Gas-Flame Detector Input Field Termination Assembly (FTA) designed to interface 16 analog current-input channels with an SAI-1620m module. It accepts 0-20 mA field signals through 500 ohm input resistance and provides corresponding 0-4 VDC outputs with 0.1% accuracy.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eInput Channel Configuration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe FS-TSGAS-1624 provides 16 analog input channels, each designed for a 0-20 mA current signal. All channels use a common 0 V reference.\u003c\/p\u003e\n\u003cp\u003eThe 500 ohm input resistance establishes the current-to-voltage conversion relationship. At the 0-20 mA input range, the nominal voltage across this resistance is 0-10 V before the assembly's signal conditioning and output stage.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSignal Interface\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe FTA provides 0-4 VDC outputs to the SAI-1620m module, with a specified accuracy of 0.1%. This voltage interface allows the receiving module to acquire the conditioned field-input signals.\u003c\/p\u003e\n\u003cp\u003eThe external 24 VDC supply powers the assembly. Its stated current draw is 3 mA without field loads, so this figure should not be treated as the total operating current when external field devices are connected.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eFS-TSGAS-1624\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eFail-Safe Gas-Flame Detector Input FTA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e16 analog channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNominal Input Signal\u003c\/td\u003e\n\u003ctd\u003e0-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Current Range\u003c\/td\u003e\n\u003ctd\u003e0-25 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Reference\u003c\/td\u003e\n\u003ctd\u003eCommon 0 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Resistance\u003c\/td\u003e\n\u003ctd\u003e500 ohm +\/-5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Voltage\u003c\/td\u003e\n\u003ctd\u003e0-4 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Interface\u003c\/td\u003e\n\u003ctd\u003eSAI-1620m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Accuracy\u003c\/td\u003e\n\u003ctd\u003e0.1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Power Supply\u003c\/td\u003e\n\u003ctd\u003e24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Consumption\u003c\/td\u003e\n\u003ctd\u003e3 mA without field loads\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuse Rating\u003c\/td\u003e\n\u003ctd\u003e500 mA, slow-acting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuse Dimensions\u003c\/td\u003e\n\u003ctd\u003e5 x 20 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuse AC Voltage Rating\u003c\/td\u003e\n\u003ctd\u003e250 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuse DC Voltage Rating\u003c\/td\u003e\n\u003ctd\u003e300 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting Rail\u003c\/td\u003e\n\u003ctd\u003eTS32 \/ TS35 x 7.5 DIN EN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUsed Rail Length\u003c\/td\u003e\n\u003ctd\u003e226 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Dimensions\u003c\/td\u003e\n\u003ctd\u003e225 x 70 x 60 mm (L x W x H)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApprovals\u003c\/td\u003e\n\u003ctd\u003eCE, TUV, UL, CSA, FM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003e\u003cstrong\u003eField Wiring and Protection\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe assembly provides field termination for 16 analog signal channels. Its screw-terminal arrangement supports connections for field signals, power supply and grounding. The hardware reference also specifies a 500 mA slow-acting fuse rated for 250 VAC or 300 VDC, with a 5 x 20 mm fuse format.\u003c\/p\u003e\n\u003cp\u003eThe specified mounting options are TS32 and TS35 x 7.5 DIN EN rails. The required rail length is 226 mm, which should be considered when checking cabinet space and replacement arrangements.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Which analog input module receives signals from the FS-TSGAS-1624?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: The specified receiving module is the Honeywell SAI-1620m. The FTA conditions the field input signals and provides 0-4 VDC outputs to this module.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the FS-TSGAS-1624 support 4-20 mA field signals?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Its documented nominal signal designation is 0-20 mA, while the hardware reference specifies an electrical input range of 0-25 mA. Confirm the detector signal configuration and system engineering requirements before using a particular signal range.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What should be checked when replacing this FTA?\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eA: Verify the complete FS-TSGAS-1624 part number, 16-channel wiring arrangement, common 0 V reference, external 24 VDC supply, fuse specification and SAI-1620m interface. Also check the DIN rail dimensions and field terminal assignments before installation.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eSources and Configuration Notes\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe specifications are cross-checked against Honeywell's \u003ci\u003eSafety Manager Hardware Reference\u003c\/i\u003e, Release 162, Issue 2.1, December 2023, Section 15.28, TSGAS-1624.\u003c\/p\u003e","brand":"HoneyWell","offers":[{"title":"Default Title","offer_id":68091791671386,"sku":"FS-TSGAS-1624","price":220.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/FS-TSGAS-16242.jpg?v=1794819264","url":"https:\/\/www.plcmasters.com\/products\/honeywell-fs-tsgas-1624-fail-safe-gas-flame-detector-input-fta","provider":"PLC Masters Ltd.","version":"1.0","type":"link"}