{"product_id":"honeywell-fx-usi-0002-safety-manager-system-module","title":"Honeywell FX-USI-0002 Safety Manager System Module","description":"\u003cp\u003eThe Honeywell FX-USI-0002 is identified as a Safety Manager System Module for Honeywell safety control systems. The supplied product information confirms the manufacturer and part number but does not specify its channel configuration, electrical characteristics, communication interfaces, or functional safety ratings.\u003c\/p\u003e\n\u003ch3\u003eFunctional Description\u003c\/h3\u003e\n\u003cp\u003eThe FX-USI-0002 is a Universal Safety Interface (USI) communication module installed in the Honeywell Safety Manager controller chassis. It manages Ethernet and serial communications between the Safety Manager controller and external devices, including Experion PKS and Safety Builder.\u003c\/p\u003e\n\u003cp\u003eThe module also provides a hardware firewall function to protect Safety Manager safety functions during external communication. Its communication resources support data exchange with other Safety Managers and connected supervisory systems.\u003c\/p\u003e\n\u003ch3\u003eCommunication Interfaces\u003c\/h3\u003e\n\u003cp\u003eThe module provides four independent communication channels, identified as A, B, C, and D.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eChannel A: 10\/100 Mbps Ethernet interface with an RJ45 connector. It connects to the SDW-550-EC through CCI-HSE-01 or CCI-HSE-02 cables.\u003c\/li\u003e\n\u003cli\u003eChannel C: General-purpose serial communication interface with a 10-pin AMP connector. It connects to DCOM-232\/485 or DCOM-485 through CCI-UNI-02 or CCI-UNI-04 cables.\u003c\/li\u003e\n\u003cli\u003eChannels B and D: Additional communication channels identified in the hardware reference. Their specific interface assignments are not detailed in the cited channel table.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe Ethernet interfaces automatically select between 10 Mbps and 100 Mbps. Honeywell recommends configuring the Ethernet port for fixed 100 Mbps, full-duplex operation.\u003c\/p\u003e\n\u003ch3\u003eHardware Architecture and Diagnostics\u003c\/h3\u003e\n\u003cp\u003eThe FX-USI-0002 incorporates dedicated communication processing and memory resources for handling multiple communication protocols.\u003c\/p\u003e\n\u003cp\u003eIts hardware architecture includes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMotorola 8270 communication processor.\u003c\/li\u003e\n\u003cli\u003e8 MB Flash memory for system and application programs.\u003c\/li\u003e\n\u003cli\u003e8 MB local SRAM with error detection and correction logic.\u003c\/li\u003e\n\u003cli\u003e256 KB shared RAM for data exchange with the Control Processor.\u003c\/li\u003e\n\u003cli\u003eTwo dual-speed Ethernet transceivers.\u003c\/li\u003e\n\u003cli\u003eTwo general-purpose serial communication controller channels.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe module performs power-up self-tests covering processor registers, local and shared memory, exception handling, and software integrity. A dedicated watchdog monitors communication processing and resets communication channels if a watchdog timeout occurs.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eFX-USI-0002\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eHoneywell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eUniversal Safety Interface Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Platform\u003c\/td\u003e\n\u003ctd\u003eSafety Manager\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Channels\u003c\/td\u003e\n\u003ctd\u003e4 independent channels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet\u003c\/td\u003e\n\u003ctd\u003e10\/100 Mbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Connector\u003c\/td\u003e\n\u003ctd\u003eRJ45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSerial Interface\u003c\/td\u003e\n\u003ctd\u003eGeneral-purpose serial\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSerial Connector\u003c\/td\u003e\n\u003ctd\u003e10-pin AMP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Protocol\u003c\/td\u003e\n\u003ctd\u003eEUCN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlash Memory\u003c\/td\u003e\n\u003ctd\u003e8 MB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLocal SRAM\u003c\/td\u003e\n\u003ctd\u003e8 MB with error detection and correction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShared RAM\u003c\/td\u003e\n\u003ctd\u003e256 KB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Transceivers\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSerial Communication Controllers\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply Voltage\u003c\/td\u003e\n\u003ctd\u003e5 V DC +\/- 5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Supply Current\u003c\/td\u003e\n\u003ctd\u003e1.2 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-5 to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 to +85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e10-95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGalvanic Isolation\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;= 2.5 kV DC between 5 V DC and Ethernet signal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet-to-Casing Isolation\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;= 1.5 kV DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupply-to-Casing Isolation\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;= 1.5 kV DC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApprovals\u003c\/td\u003e\n\u003ctd\u003eCE, TUV, UL, CSA, FM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (H x W x D)\u003c\/td\u003e\n\u003ctd\u003e176 x 35.2 x 212 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.7 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eSystem Compatibility and Replacement\u003c\/h3\u003e\n\u003cp\u003eThe FX-USI-0002 is documented as a replacement for the following earlier Universal Safety Interface modules:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFC-USI-0001\u003c\/li\u003e\n\u003cli\u003eFC-USI-0002\u003c\/li\u003e\n\u003cli\u003eFE-USI-0002\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eHoneywell specifies that the FX-USI-0002 supports replacement from Safety Manager software release R140 and higher. The replacement relationship is relevant when maintaining existing controller installations, but the installed software release should be checked before ordering or replacing the module.\u003c\/p\u003e\n\u003cp\u003eThe FX-USI-0002 also supports the EUCN protocol, which is relevant when checking communication compatibility with existing Safety Manager configurations.\u003c\/p\u003e\n\u003ch3\u003eInstallation and Maintenance Considerations\u003c\/h3\u003e\n\u003cp\u003eThe module is installed in the Safety Manager Controller chassis and occupies a communication module position.\u003c\/p\u003e\n\u003cp\u003eHoneywell documents hot-swap functionality: the module can be inserted or removed while the system is running without interrupting the application program.\u003c\/p\u003e\n\u003cp\u003eBefore replacement, verify the controller software release, communication configuration, cable connections, and channel assignments.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: Can the FX-USI-0002 replace the older FE-USI-0002 module?\u003c\/p\u003e\n\u003cp\u003eA: Yes. Honeywell identifies the FX-USI-0002 as a replacement for FE-USI-0002, FC-USI-0001, and FC-USI-0002. The Safety Manager software must meet the R140 or higher compatibility requirement.\u003c\/p\u003e\n\u003cp\u003eQ: Does the FX-USI-0002 support hot swapping?\u003c\/p\u003e\n\u003cp\u003eA: Yes. The module supports insertion and removal in a running Safety Manager system without interrupting the application program.\u003c\/p\u003e\n\u003cp\u003eQ: What communication interfaces are available on the FX-USI-0002?\u003c\/p\u003e\n\u003cp\u003eA: The module provides four independent communication channels, including a 10\/100 Mbps Ethernet interface and a general-purpose serial interface. The exact cable and external interface requirements depend on the selected channel and system configuration.\u003c\/p\u003e","brand":"HoneyWell","offers":[{"title":"Default Title","offer_id":42000138043482,"sku":"FX-USI-0002","price":200.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/FX-USI-0002.jpg?v=1750141653","url":"https:\/\/www.plcmasters.com\/products\/honeywell-fx-usi-0002-safety-manager-system-module","provider":"PLC Masters Ltd.","version":"1.0","type":"link"}