Skip to content
ICS Triplex T7122 Regent 32-Channel 24 VDC Digital Input Module

ICS Triplex T7122 Regent 32-Channel 24 VDC Digital Input Module

  • 16 In stock
  • Manufacturer: ICS Triplex

  • Product No.: T7122

  • Condition: In stock

  • Product Type: Regent 32-Channel 24 VDC Digital Input Module

  • Payment:T/T, Western Union

  • Weight: 1200g

  • Shipping port: Xiamen

  • Warranty: 12 months

{"id":44010671538266,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"T7122","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"ICS Triplex T7122 Regent 32-Channel 24 VDC Digital Input Module","public_title":null,"options":["Default Title"],"price":12300,"weight":1200,"compare_at_price":32000,"inventory_management":"shopify","barcode":null,"requires_selling_plan":false,"selling_plan_allocations":[],"quantity_rule":{"min":1,"max":null,"increment":1}}

Description

Configured for isolated discrete signal monitoring in Regent T3xxx safety systems, the ICS Triplex T7122, also cataloged as the T7122 Digital Input Module, provides direct physical/electrical execution.

Hardware Specifications

Parameter Specification
Model T7122
Brand ICS Triplex
Origin United Kingdom
Weight 1.2 kg
Operating Temp 0 to 60 deg C
Storage Temp -40 to 85 deg C
Power Consumption Nominal 24 VDC backplane supply
Channel Capacity 32 monitored inputs (4 isolated groups of 8 channels)
Nominal Voltage 24 VDC (18 to 32 VDC operating range)
Input Current 7 mA typical at 24 VDC
Galvanic Isolation 2500 V optical/galvanic barrier between field and logic
System Bus Interface Triplicated Safetybus
Safety Certification IEC 61508 SIL 3, TUV Certified, Risk Class 5
Line Monitoring Continuous open-circuit and short-circuit fault detection
Maintenance Fully hot-swappable

Fail-Safe Architecture and Triple Modular Redundancy

The T7122 Digital Input Module operates within a high-integrity fault-tolerant environment utilizing guarded dual-redundant logic with voter circuits. Designed to maintain SIL 3 safety integrity, the hardware executes direct signal acquisition from field contacts through a 2500 V optical barrier that prevents high-voltage transients from propagating to the triplicated Safetybus architecture.

Internal diagnostic circuits continuously evaluate line conditions to detect open-circuit and short-circuit field wiring events. Logic processing guarantees a fail-safe state execution, defaulting input values to a defined safe state in the event of hardware degradation, fuse cleavage, or loss of loop power.

Frequently Asked Questions

Q: Can the T7122 module be replaced while the system is powered and executing safety logic?

A: Yes, the T7122 supports full hot-swap operations. The module can be extracted and inserted into an active Regent rack chassis without de-energizing the system or disrupting parallel safety instrumentation loops.

Q: How does the module handle overcurrent conditions on individual field input channels?

A: Channel inputs are segmented into four distinct groups of eight. Each group features dedicated fuses accessible from the front panel to isolate overcurrent conditions and maintain channel group independence.

Field Installation Guidelines

  1. DIN Rack Alignment & Insertion: Ensure the card edge guides inside the Regent rack frame are clear of debris. Insert the T7122 vertically until the backplane contacts align, then apply firm, even pressure to seat the multi-pin connector into the triplicated Safetybus backplane. Fasten top and bottom retaining screws to ensure proper grounding.
  2. Field Cable Shielding: Terminate all 24 VDC digital input signal cables using twisted-pair wiring. Connect signal shields strictly to the designated system functional earth (FE) bus bar at a single point to prevent ground loops from corrupting discrete sensor state detection.
  3. Line Monitoring Setup: Ensure external field contacts comply with minimum loop resistance thresholds to maintain open-circuit and short-circuit diagnostics. Check individual group fuses on the front panel prior to energizing field loops.

Features

We welcome bulk orders and have a minimum order quantity of just one unit.

Upon request, we can provide all necessary documentation, including Certificates of Origin/Conformance and other required export documents.

For items in stock, we aim to deliver within 1-3 days after payment confirmation. Items with specified lead times will be delivered according to the quoted schedule.

We accept 100% T/T (Telegraphic Transfer) payment before shipping. For items with lead times, a 30% deposit is required upfront, with the remaining 70% due before shipment. For RMB transfers, please contact us if you have an agent in China.

We offer a standard one-year warranty on all new and original items. If you require an extended warranty, please contact us for additional cost details.

Your satisfaction is important to us. If you need to return an item, it must be done within 30 days of the order date. The product must be unused, unopened, and in its original packaging with all accessories included. Refunds are processed within 5-7 business days after we receive the returned item. Please note that shipping and related charges are non-refundable.

Featured

Complementary products