{"product_id":"ics-triplex-tc-501-02-4m5-multi-core-i-o-interface-cable","title":"ICS Triplex TC-501-02-4M5 Multi-Core I\/O Interface Cable","description":"\u003ch2\u003eICS Triplex TC-501-02-4M5 Multi-Core I\/O Interface Cable\u003c\/h2\u003e\n\u003cp\u003eConfigured for processor-to-termination signal transmission in the ICS Triplex Trusted TMR system, the \u003cstrong\u003eICS Triplex TC-501-02-4M5\u003c\/strong\u003e (\u003cstrong\u003eTC-501-02-4M5\u003c\/strong\u003e I\/O interface cable) provides a 4.5 m shielded multi-conductor connection between Trusted I\/O processor modules and Field Termination Assemblies or marshalling panels. The cable uses internal twisted-pair wiring and overall shielding for separated channel signal transmission.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eTC-501-02-4M5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eICS Triplex\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Type\u003c\/td\u003e\n\u003ctd\u003eMulti-conductor shielded I\/O interface cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Compatibility\u003c\/td\u003e\n\u003ctd\u003eICS Triplex Trusted TMR system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication Connection\u003c\/td\u003e\n\u003ctd\u003eTrusted I\/O processor to FTA or marshalling panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable Length\u003c\/td\u003e\n\u003ctd\u003e4.5 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductor Material\u003c\/td\u003e\n\u003ctd\u003eTinned copper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eShielding\u003c\/td\u003e\n\u003ctd\u003eAluminum-Mylar foil and tinned copper braid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOuter Jacket Material\u003c\/td\u003e\n\u003ctd\u003eFlame-retardant polyurethane \/ PVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLow Smoke Halogen Free Option\u003c\/td\u003e\n\u003ctd\u003eAvailable according to supplied data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Voltage\u003c\/td\u003e\n\u003ctd\u003e24 VDC nominal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e-20 deg C to +70 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eCable diameter not specified in supplied data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNot applicable; passive cable assembly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector\u003c\/td\u003e\n\u003ctd\u003ePre-terminated high-density industrial connectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSignal Architecture\u003c\/td\u003e\n\u003ctd\u003eTriple-channel TMR signal wiring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEMI\/RFI Protection\u003c\/td\u003e\n\u003ctd\u003eOverall foil and braided shielding\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eTMR Signal Isolation and Fail-Safe Wiring\u003c\/h3\u003e\n\u003cp\u003eThe TC-501-02-4M5 is intended for the signal interface between Trusted TMR processor or I\/O hardware and field termination equipment. Internal twisted-pair conductors separate signal paths and reduce coupling between channels.\u003c\/p\u003e\n\u003cp\u003eThe cable uses an overall aluminum-Mylar foil shield with a tinned copper braid. This construction provides a conductive shield around the signal conductors and reduces susceptibility to externally coupled EMI and RFI. Shield termination should follow the grounding arrangement specified for the installed Trusted system and FTA assembly.\u003c\/p\u003e\n\u003cp\u003eThe cable is used for fault-tolerant signal wiring in Safety Instrumented System, Emergency Shutdown, and Fire and Gas applications. The cable itself does not perform voting logic or fault diagnostics; those functions remain within the associated Trusted control hardware.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003eQ: What is the specified cable length of the TC-501-02-4M5?\u003c\/p\u003e\n\u003cp\u003eA: The specified cable length is 4.5 m.\u003c\/p\u003e\n\u003cp\u003eQ: What shielding construction is specified for this cable?\u003c\/p\u003e\n\u003cp\u003eA: The cable uses an overall aluminum-Mylar foil shield combined with a tinned copper braid.\u003c\/p\u003e\n\u003cp\u003eQ: Is the TC-501-02-4M5 a powered electronic module?\u003c\/p\u003e\n\u003cp\u003eA: No. It is a passive interface cable assembly. The supplied data specifies a 24 VDC nominal operating signal environment but does not assign a power consumption value to the cable.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the cable between the designated Trusted processor or I\/O interface and the corresponding FTA or marshalling connection. Verify connector orientation and pin assignment against the applicable system wiring documentation before energization.\u003c\/p\u003e\n\u003cp\u003eMaintain the specified fixed-installation bending radius of approximately 10 x cable diameter. Avoid sharp bends, crushing, excessive tensile loading, and mechanical strain at the connector bodies.\u003c\/p\u003e\n\u003cp\u003eRoute the cable separately from high-current power conductors and other strong electromagnetic noise sources where the installation permits. Maintain the shield continuity through the intended termination points and apply the site grounding scheme specified for the Trusted system.\u003c\/p\u003e\n\u003cp\u003eBefore commissioning, inspect the cable jacket, connectors, shield termination, and mechanical routing. Verify conductor continuity and absence of unintended shorts between signal paths according to the applicable maintenance or commissioning procedure.\u003c\/p\u003e","brand":"ICS Triplex","offers":[{"title":"Default Title","offer_id":44049413636186,"sku":"TC-501-02-4M5","price":123.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/TC-011-02-1M51.jpg?v=1789119583","url":"https:\/\/www.plcmasters.com\/products\/ics-triplex-tc-501-02-4m5-multi-core-i-o-interface-cable","provider":"PLC Masters Ltd.","version":"1.0","type":"link"}