{"product_id":"prosoft-mvi46-mcm-modbus-master-slave-for-allen-bradley-slc-500","title":"ProSoft MVI46-MCM Modbus Master\/Slave for Allen Bradley SLC 500","description":"\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eProSoft MVI46-MCM\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a versatile communication module designed to integrate Modbus RTU and Modbus ASCII devices with Allen-Bradley SLC 500 PLC systems. Compatible with SLC 5\/02 and later processors, it facilitates reliable, deterministic data exchange between SLC processors and a broad range of Modbus-enabled devices including drives, meters, and remote I\/O.\u003c\/p\u003e\n\u003cp\u003eThis module is ideal for modernizing legacy systems, supporting both master and slave operations, and providing seamless integration into industrial environments that require robust Modbus communication.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDual Serial Ports\u003c\/strong\u003e: Two fully isolated RS-232\/422\/485 serial ports, independently configurable for master or slave operation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModbus Protocols Supported\u003c\/strong\u003e: Modbus RTU and Modbus ASCII, enabling broad compatibility with various devices.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eData Handling\u003c\/strong\u003e: Capable of handling up to 5,000 registers, supports integer, floating-point, and bit-level data types.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConfiguration\u003c\/strong\u003e: Easily configured with ProSoft Configuration Builder (PCB).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDiagnostics\u003c\/strong\u003e: Built-in LED indicators for module, backplane status, application status, and serial port activity, simplifying troubleshooting.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSlot Compatibility\u003c\/strong\u003e: Single-slot module that fits any 1746 SLC 500 backplane, supporting both local and extended rack configurations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003e\u003cstrong\u003eParameter\u003c\/strong\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cstrong\u003eSpecification\u003c\/strong\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eModule Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModbus Master\/Slave communication module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePlatform\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley SLC 500 (1746)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBackplane Data Transfer\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOptimized for SLC processors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConfiguration Software\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eProSoft Configuration Builder (PCB)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMemory\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8,000-word data exchange database\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eProtocols Supported\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModbus RTU, Modbus ASCII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Modes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMaster, Slave, Master + Slave simultaneously\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSerial Ports\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 x Isolated RS-232\/422\/485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBaud Rates\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e110 to 115,200 bps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eMax Registers\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5,000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSupported Data Types\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eInteger, Floating-point, Bit-level\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0°C to 60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-40°C to 85°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eShock Resistance\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e30 g operational, 50 g non-operational\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHumidity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5% to 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 5 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIsolation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1500 V between serial ports and backplane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSlot Requirement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 SLC 1746 slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLED Indicators\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eModule status, Backplane status, Serial activity, Application status, Error LED status\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eProSoft MVI46-MCM\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis widely used in applications requiring seamless Modbus communication with SLC 500 systems. Common uses include:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOil \u0026amp; Gas\u003c\/strong\u003e: Wellhead control, pipeline monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWater Treatment\u003c\/strong\u003e: Remote monitoring and control of water systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Generation\u003c\/strong\u003e: Integration with power plant DCS and control systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eManufacturing\u003c\/strong\u003e: Industrial network integration and automation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLegacy System Modernization\u003c\/strong\u003e: Ideal for upgrading legacy SLC systems with modern Modbus communication capabilities\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Can this module support both Modbus Master and Slave at the same time?\u003c\/strong\u003e\u003cbr\u003eYes, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eProSoft MVI46-MCM\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esupports both Modbus Master and Slave communication modes simultaneously, allowing for flexible integration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: How many devices can I connect to this module?\u003c\/strong\u003e\u003cbr\u003eThe module can support up to 5,000 Modbus registers and allows communication with multiple Modbus devices, depending on your system’s configuration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: What is the configuration process like?\u003c\/strong\u003e\u003cbr\u003eThe module is easily configured using the ProSoft Configuration Builder (PCB), a user-friendly software tool that simplifies setup and deployment.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: Can this module be used with older SLC 500 systems?\u003c\/strong\u003e\u003cbr\u003eYes, it is compatible with SLC 5\/02 processors and later models, making it ideal for upgrading older systems.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":43290083950682,"sku":"MVI46-MCM","price":188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/MVI46-MCM2.jpg?v=1777456831","url":"https:\/\/www.plcmasters.com\/products\/prosoft-mvi46-mcm-modbus-master-slave-for-allen-bradley-slc-500","provider":"PLC Masters Ltd.","version":"1.0","type":"link"}