ProSoft MVI46-MCM Modbus Master/Slave for Allen Bradley SLC 500

ProSoft MVI46-MCM Modbus Master/Slave for Allen Bradley SLC 500

  • 1000 In stock
  • Manufacturer: Allen-Bradley

  • Product No.: MVI46-MCM

  • Condition: In stock

  • Product Type: Modbus Master/Slave for Allen Bradley SLC 500

  • Product Origin: USA

  • Payment:T/T, Western Union

  • Weight: 408g

  • Shipping port: Xiamen

  • Warranty: 12 months

{"id":43290083950682,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"MVI46-MCM","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"ProSoft MVI46-MCM Modbus Master\/Slave for Allen Bradley SLC 500","public_title":null,"options":["Default Title"],"price":18800,"weight":408,"compare_at_price":32000,"inventory_management":"shopify","barcode":"USA","requires_selling_plan":false,"selling_plan_allocations":[],"quantity_rule":{"min":1,"max":null,"increment":1}}

Description

Product Overview

The ProSoft MVI46-MCM is a versatile communication module designed to integrate Modbus RTU and Modbus ASCII devices with Allen-Bradley SLC 500 PLC systems. Compatible with SLC 5/02 and later processors, it facilitates reliable, deterministic data exchange between SLC processors and a broad range of Modbus-enabled devices including drives, meters, and remote I/O.

This module is ideal for modernizing legacy systems, supporting both master and slave operations, and providing seamless integration into industrial environments that require robust Modbus communication.

Key Features

  • Dual Serial Ports: Two fully isolated RS-232/422/485 serial ports, independently configurable for master or slave operation.

  • Modbus Protocols Supported: Modbus RTU and Modbus ASCII, enabling broad compatibility with various devices.

  • Data Handling: Capable of handling up to 5,000 registers, supports integer, floating-point, and bit-level data types.

  • Configuration: Easily configured with ProSoft Configuration Builder (PCB).

  • Diagnostics: Built-in LED indicators for module, backplane status, application status, and serial port activity, simplifying troubleshooting.

  • Slot Compatibility: Single-slot module that fits any 1746 SLC 500 backplane, supporting both local and extended rack configurations.

Technical Specifications

Parameter Specification
Module Type Modbus Master/Slave communication module
Platform Allen-Bradley SLC 500 (1746)
Backplane Data Transfer Optimized for SLC processors
Configuration Software ProSoft Configuration Builder (PCB)
Memory 8,000-word data exchange database
Protocols Supported Modbus RTU, Modbus ASCII
Operating Modes Master, Slave, Master + Slave simultaneously
Serial Ports 2 x Isolated RS-232/422/485
Baud Rates 110 to 115,200 bps
Max Registers 5,000
Supported Data Types Integer, Floating-point, Bit-level
Operating Temperature 0°C to 60°C
Storage Temperature -40°C to 85°C
Shock Resistance 30 g operational, 50 g non-operational
Humidity 5% to 95% non-condensing
Power Consumption < 5 W
Isolation 1500 V between serial ports and backplane
Slot Requirement 1 SLC 1746 slot
LED Indicators Module status, Backplane status, Serial activity, Application status, Error LED status

Applications

The ProSoft MVI46-MCM is widely used in applications requiring seamless Modbus communication with SLC 500 systems. Common uses include:

  • Oil & Gas: Wellhead control, pipeline monitoring

  • Water Treatment: Remote monitoring and control of water systems

  • Power Generation: Integration with power plant DCS and control systems

  • Manufacturing: Industrial network integration and automation

  • Legacy System Modernization: Ideal for upgrading legacy SLC systems with modern Modbus communication capabilities

FAQ

Q1: Can this module support both Modbus Master and Slave at the same time?
Yes, the ProSoft MVI46-MCM supports both Modbus Master and Slave communication modes simultaneously, allowing for flexible integration.

Q2: How many devices can I connect to this module?
The module can support up to 5,000 Modbus registers and allows communication with multiple Modbus devices, depending on your system’s configuration.

Q3: What is the configuration process like?
The module is easily configured using the ProSoft Configuration Builder (PCB), a user-friendly software tool that simplifies setup and deployment.

Q4: Can this module be used with older SLC 500 systems?
Yes, it is compatible with SLC 5/02 processors and later models, making it ideal for upgrading older systems.

Features

We welcome bulk orders and have a minimum order quantity of just one unit.

Upon request, we can provide all necessary documentation, including Certificates of Origin/Conformance and other required export documents.

For items in stock, we aim to deliver within 1-3 days after payment confirmation. Items with specified lead times will be delivered according to the quoted schedule.

We accept 100% T/T (Telegraphic Transfer) payment before shipping. For items with lead times, a 30% deposit is required upfront, with the remaining 70% due before shipment. For RMB transfers, please contact us if you have an agent in China.

We offer a standard one-year warranty on all new and original items. If you require an extended warranty, please contact us for additional cost details.

Your satisfaction is important to us. If you need to return an item, it must be done within 30 days of the order date. The product must be unused, unopened, and in its original packaging with all accessories included. Refunds are processed within 5-7 business days after we receive the returned item. Please note that shipping and related charges are non-refundable.

Featured

Complementary products