{"product_id":"prosoft-mvi56e-mnetc-modbus-tcp-controllogix-gateway-module","title":"ProSoft MVI56E-MNETC Modbus TCP ControlLogix Gateway Module","description":"\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe ProSoft\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMVI56E-MNETC\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis an enhanced communication interface designed to connect Allen-Bradley ControlLogix platforms with Modbus TCP\/IP networks. It enables bidirectional data exchange between Ethernet-based industrial devices and PLC control systems without requiring protocol conversion hardware beyond the module itself.\u003c\/p\u003e\n\u003cp\u003eBuilt on the ProSoft E-Series architecture, the module is optimized for high-throughput applications, supporting simultaneous client and server communication with stable performance under heavy network loads.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCommunication Architecture\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eModbus TCP\/IP Interface\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eProtocol: Modbus TCP\/IP over Ethernet\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOperating Modes: Client (Master), Server (Slave), or simultaneous operation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEthernet Interface: 10\/100 Mbps, auto-negotiation, full\/half duplex\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConnection Capacity:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eUp to 30 client sessions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUp to 10 server sessions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003eSupported Functions:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eRead\/Write Coils\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRead\/Write Holding Registers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInput Registers and Discrete Inputs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003eData Handling: Supports integer, floating-point, and bit-level mapping\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMaximum Data Capacity: Up to 10,000 registers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eControlLogix Integration\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eBackplane: High-speed optimized data transfer for ControlLogix chassis\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSlot Requirement: Single standard ControlLogix slot\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConfiguration Tool: ProSoft Configuration Builder (PCB)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDiagnostics Access: Embedded web server for live monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStatus Feedback: Ethernet, module, application, and backplane indicators\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eHardware \u0026amp; Environmental Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eOperating Temperature: -20°C to +60°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStorage Temperature: -40°C to +85°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower Consumption: \u0026lt; 5 W typical\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eElectrical Isolation: 1500 V (Ethernet to backplane)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHumidity Range: 5–95% non-condensing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVibration\/Shock: IEC 60068-2 compliant\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRack Compatibility: Local or remote ControlLogix chassis\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Engineering Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eHigh-performance Modbus TCP\/IP processing engine\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConcurrent client\/server communication architecture\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOptimized backplane bandwidth utilization\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBuilt-in web-based diagnostics and statistics\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupports redundant Ethernet network configurations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDesigned for large-scale data exchange environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStable operation under continuous industrial load conditions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTypical Application Areas\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSCADA and distributed control system integration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower generation monitoring and control networks\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOil \u0026amp; gas production and pipeline automation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWater and wastewater treatment systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eChemical and process manufacturing plants\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Can the module operate as both client and server at the same time?\u003c\/strong\u003e\u003cbr\u003eYes, it supports simultaneous Modbus TCP client and server operation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: What is the maximum number of connections supported?\u003c\/strong\u003e\u003cbr\u003eUp to 30 client and 10 server connections can run concurrently.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: Does it support large data mapping?\u003c\/strong\u003e\u003cbr\u003eYes, it supports up to 10,000 Modbus registers with multiple data types.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: Is it suitable for redundant Ethernet networks?\u003c\/strong\u003e\u003cbr\u003eYes, it is compatible with redundant network topologies used in ControlLogix systems.\u003c\/p\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":43290072285274,"sku":"MVI56E-MNETC","price":188.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/MVI56E-MCMXT1.jpg?v=1777455054","url":"https:\/\/www.plcmasters.com\/products\/prosoft-mvi56e-mnetc-modbus-tcp-controllogix-gateway-module","provider":"PLC Masters Ltd.","version":"1.0","type":"link"}