Skip to content
ProSoft MVI56E-MNETR Modbus TCP/IP Client/Server Enhanced Communication Module

ProSoft MVI56E-MNETR Modbus TCP/IP Client/Server Enhanced Communication Module

  • 16 In stock
  • Manufacturer: AMPHENOL

  • Product No.: MVI56E-MNETR

  • Condition: In stock

  • Product Type: Modbus TCP/IP Client/Server Enhanced Communication Module

  • Product Origin: USA

  • Payment:T/T, Western Union

  • Weight: 1361g

  • Shipping port: Xiamen

  • Warranty: 12 months

{"id":43931776909402,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"MVI56E-MNETR","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"ProSoft MVI56E-MNETR Modbus TCP\/IP Client\/Server Enhanced Communication Module","public_title":null,"options":["Default Title"],"price":12300,"weight":1361,"compare_at_price":32000,"inventory_management":"shopify","barcode":"USA","requires_selling_plan":false,"selling_plan_allocations":[],"quantity_rule":{"min":1,"max":null,"increment":1}}

Description

ProSoft MVI56E-MNETR Modbus TCP/IP Client/Server Enhanced Communication Module

Configured for Modbus TCP/IP client and server communication in ControlLogix systems, the ProSoft MVI56E-MNETR (MVI56E-MNETR Enhanced Communication Module) provides Ethernet data exchange through ladder logic data transfer. The module occupies one slot and uses a 10/100 Mbps Ethernet interface.

Hardware Specifications

Parameter Specification
Model MVI56E-MNETR
Brand ProSoft
Product Type Modbus TCP/IP Client/Server Enhanced Communication Modules
Product Line ControlLogix
Weight 3.00 lbs
Operating Temp 0 deg C to 60 deg C
Storage Temp -40 deg C to 85 deg C
Relative Humidity 5% to 95%, non-condensing
Power Consumption Backplane load: 800 mA at 5 VDC; 3 mA at 24 VDC
Slot Requirement 1 slot
Rack Type Remote
Data Transfer Type Ladder Logic
Ethernet Configuration 10/100 Mbps
User-Definable Module Data Memory Mapping 5,000 registers
Client Connection Commands 100 maximum
Shock 30 g operational
Communication Function Modbus TCP/IP Client/Server
Data Block Type Reduced Data Block

Modbus TCP/IP Communication and ControlLogix Integration

The MVI56E-MNETR provides Modbus TCP/IP client and server functions through a ControlLogix backplane interface. Ladder logic transfers application data between the ControlLogix processor and module data areas.

The Ethernet interface supports 10/100 Mbps operation for Modbus TCP/IP communication. User-definable data memory mapping provides capacity for up to 5,000 registers.

The module supports up to 100 client connection commands. Therefore, application configuration must account for the required Modbus TCP/IP connection structure and processor data mapping.

The specified backplane current load is 800 mA at 5 VDC, with an additional 3 mA at 24 VDC. Backplane power budgeting must include the module load together with all other installed modules.

Frequently Asked Questions

Q: How much ControlLogix rack space does the MVI56E-MNETR require?
A: The module requires one ControlLogix slot and is specified for remote rack installation.

Q: What Ethernet communication speed does the module support?
A: The supplied specifications identify a 10/100 Mbps Ethernet configuration for Modbus TCP/IP communication.

Q: What backplane current must be included in the rack power calculation?
A: The specified backplane load is 800 mA at 5 VDC, with 3 mA at 24 VDC.

Field Installation Guidelines

Install the module in an approved ControlLogix rack position with the backplane power budget verified before energization.

Confirm that the rack configuration provides sufficient current capacity for the stated 5 VDC and 24 VDC module loads.

Use Ethernet cabling and connectors suitable for the installed industrial environment and maintain physical separation from high-voltage or high-current conductors.

Route communication wiring separately from motor, contactor, transformer, and other high-noise circuits where practical.

Terminate cable shields according to the installation standard and system grounding design. Avoid creating unintended ground loops through shield connections.

Verify the Ethernet network configuration before enabling Modbus TCP/IP client or server communications.

Confirm ladder logic data mapping against the configured module memory addresses before placing the communication path into service.

Maintain the specified operating temperature and non-condensing humidity range during normal operation.

During commissioning, verify Modbus TCP/IP connectivity, register mapping, client connection commands, and processor-to-module data transfer independently.

Features

We welcome bulk orders and have a minimum order quantity of just one unit.

Upon request, we can provide all necessary documentation, including Certificates of Origin/Conformance and other required export documents.

For items in stock, we aim to deliver within 1-3 days after payment confirmation. Items with specified lead times will be delivered according to the quoted schedule.

We accept 100% T/T (Telegraphic Transfer) payment before shipping. For items with lead times, a 30% deposit is required upfront, with the remaining 70% due before shipment. For RMB transfers, please contact us if you have an agent in China.

We offer a standard one-year warranty on all new and original items. If you require an extended warranty, please contact us for additional cost details.

Your satisfaction is important to us. If you need to return an item, it must be done within 30 days of the order date. The product must be unused, unopened, and in its original packaging with all accessories included. Refunds are processed within 5-7 business days after we receive the returned item. Please note that shipping and related charges are non-refundable.