Skip to content
ProSoft MVI69E-MBS Modbus Serial Enhanced Communication Module

ProSoft MVI69E-MBS Modbus Serial Enhanced Communication Module

  • 16 In stock
  • Manufacturer: AMPHENOL

  • Product No.: MVI69E-MBS

  • Condition: In stock

  • Product Type: Modbus Serial Enhanced Communication Module

  • Product Origin: USA

  • Payment:T/T, Western Union

  • Weight: 454g

  • Shipping port: Xiamen

  • Warranty: 12 months

{"id":43968662700122,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"MVI69E-MBS","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"ProSoft MVI69E-MBS Modbus Serial Enhanced Communication Module","public_title":null,"options":["Default Title"],"price":12300,"weight":454,"compare_at_price":32000,"inventory_management":"shopify","barcode":"USA","requires_selling_plan":false,"selling_plan_allocations":[],"quantity_rule":{"min":1,"max":null,"increment":1}}

Description

ProSoft MVI69E-MBS Modbus Serial Enhanced Communication Module

Configured for Modbus serial data exchange in CompactLogix systems, the ProSoft MVI69E-MBS (MVI69E-MBS Modbus Serial Enhanced Communication Module) provides two RJ45 application serial ports and Ethernet-based configuration.

Hardware Specifications

Parameter Specification
Model MVI69E-MBS
Brand ProSoft
Origin Not specified in supplied data
Product Type Modbus Serial Communication Module
Product Line CompactLogix
Compatible Processors CompactLogix L2, L3, and L4
Weight 1.00 lb
Dimensions Standard 1769 single-slot module
Application Serial Ports 2 x RJ45
Configuration Port 10/100 Mbps Ethernet
Data Capacity 10,000 words
Command Support 250 commands per port
I/O Size 60 / 120 / 240 x 16-bit integers
Modbus Modes RTU with CRC-16; ASCII with LRC error checking
Node Address 1 to 247, software selectable
Operating Temp 0 deg C to 60 deg C
Storage Temp -40 deg C to 85 deg C
Relative Humidity 5% to 95%, non-condensing
Installation Altitude 1000 m
Power Consumption Not specified in supplied data
Configuration Software ProSoft Configuration Builder

Modbus Serial Protocol and Communication Characteristics

The MVI69E-MBS supports Modbus RTU and Modbus ASCII communication through its application serial interfaces.

RTU communication uses binary data representation with CRC-16 error checking, while ASCII mode uses LRC error checking.

Each configured slave port provides status information including error codes, communication counters, and port status.

Software-selectable node addressing supports Modbus addresses from 1 through 247 for configured network devices.

The module provides up to 250 commands per port, with a stated data capacity of 10,000 words.

The Ethernet interface operates at 10/100 Mbps and is specified as the configuration port.

Frequently Asked Questions (FAQ)

Q: Which CompactLogix processors are compatible with the MVI69E-MBS?
A: The supplied specifications identify CompactLogix L2, L3, and L4 processors as compatible processor platforms.

Q: Which Modbus communication modes are supported?
A: The module supports Modbus RTU using CRC-16 error checking and Modbus ASCII using LRC error checking.

Q: Does the supplied documentation specify module power consumption?
A: No power consumption value is provided in the supplied technical information, so no numerical value is assigned here.

Field Installation Guidelines

Install the module in the specified 1769 single-slot CompactLogix position according to the controller hardware documentation.

Verify processor compatibility before energizing the chassis and confirm that the module is mechanically seated correctly.

Route serial communication wiring separately from high-voltage conductors, motor cables, and high-current switching circuits.

Maintain appropriate cable shielding and terminate shields according to the plant grounding architecture and the connected serial-device requirements.

Avoid creating unintended ground loops through shield connections, especially where equipment receives power from separate distribution points.

Confirm RJ45 connector assignments before connecting field devices because the application serial ports and Ethernet configuration port serve different functions.

Configure the Modbus node address, communication mode, commands, and data allocation using the applicable ProSoft configuration software.

Verify RTU CRC-16 or ASCII LRC error handling during commissioning by checking the available status counters and error information.

Do not exceed the stated operating temperature, storage temperature, humidity, or installation altitude limits.

Features

We welcome bulk orders and have a minimum order quantity of just one unit.

Upon request, we can provide all necessary documentation, including Certificates of Origin/Conformance and other required export documents.

For items in stock, we aim to deliver within 1-3 days after payment confirmation. Items with specified lead times will be delivered according to the quoted schedule.

We accept 100% T/T (Telegraphic Transfer) payment before shipping. For items with lead times, a 30% deposit is required upfront, with the remaining 70% due before shipment. For RMB transfers, please contact us if you have an agent in China.

We offer a standard one-year warranty on all new and original items. If you require an extended warranty, please contact us for additional cost details.

Your satisfaction is important to us. If you need to return an item, it must be done within 30 days of the order date. The product must be unused, unopened, and in its original packaging with all accessories included. Refunds are processed within 5-7 business days after we receive the returned item. Please note that shipping and related charges are non-refundable.

Featured

Complementary products