{"product_id":"prosoft-mvi69e-mbs-modbus-serial-enhanced-communication-module","title":"ProSoft MVI69E-MBS Modbus Serial Enhanced Communication Module","description":"\u003ch2\u003eProSoft MVI69E-MBS Modbus Serial Enhanced Communication Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for Modbus serial data exchange in CompactLogix systems, the \u003cstrong\u003eProSoft MVI69E-MBS\u003c\/strong\u003e (\u003cstrong\u003eMVI69E-MBS\u003c\/strong\u003e Modbus Serial Enhanced Communication Module) provides two RJ45 application serial ports and Ethernet-based configuration.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMVI69E-MBS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eProSoft\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOrigin\u003c\/td\u003e\n\u003ctd\u003eNot specified in supplied data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eModbus Serial Communication Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Line\u003c\/td\u003e\n\u003ctd\u003eCompactLogix\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Processors\u003c\/td\u003e\n\u003ctd\u003eCompactLogix L2, L3, and L4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.00 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eStandard 1769 single-slot module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplication Serial Ports\u003c\/td\u003e\n\u003ctd\u003e2 x RJ45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration Port\u003c\/td\u003e\n\u003ctd\u003e10\/100 Mbps Ethernet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Capacity\u003c\/td\u003e\n\u003ctd\u003e10,000 words\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommand Support\u003c\/td\u003e\n\u003ctd\u003e250 commands per port\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Size\u003c\/td\u003e\n\u003ctd\u003e60 \/ 120 \/ 240 x 16-bit integers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModbus Modes\u003c\/td\u003e\n\u003ctd\u003eRTU with CRC-16; ASCII with LRC error checking\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNode Address\u003c\/td\u003e\n\u003ctd\u003e1 to 247, software selectable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to 85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation Altitude\u003c\/td\u003e\n\u003ctd\u003e1000 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eNot specified in supplied data\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration Software\u003c\/td\u003e\n\u003ctd\u003eProSoft Configuration Builder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eModbus Serial Protocol and Communication Characteristics\u003c\/h3\u003e\n\u003cp\u003eThe MVI69E-MBS supports Modbus RTU and Modbus ASCII communication through its application serial interfaces.\u003c\/p\u003e\n\u003cp\u003eRTU communication uses binary data representation with CRC-16 error checking, while ASCII mode uses LRC error checking.\u003c\/p\u003e\n\u003cp\u003eEach configured slave port provides status information including error codes, communication counters, and port status.\u003c\/p\u003e\n\u003cp\u003eSoftware-selectable node addressing supports Modbus addresses from 1 through 247 for configured network devices.\u003c\/p\u003e\n\u003cp\u003eThe module provides up to 250 commands per port, with a stated data capacity of 10,000 words.\u003c\/p\u003e\n\u003cp\u003eThe Ethernet interface operates at 10\/100 Mbps and is specified as the configuration port.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Which CompactLogix processors are compatible with the MVI69E-MBS?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The supplied specifications identify CompactLogix L2, L3, and L4 processors as compatible processor platforms.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Which Modbus communication modes are supported?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The module supports Modbus RTU using CRC-16 error checking and Modbus ASCII using LRC error checking.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the supplied documentation specify module power consumption?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e No power consumption value is provided in the supplied technical information, so no numerical value is assigned here.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the module in the specified 1769 single-slot CompactLogix position according to the controller hardware documentation.\u003c\/p\u003e\n\u003cp\u003eVerify processor compatibility before energizing the chassis and confirm that the module is mechanically seated correctly.\u003c\/p\u003e\n\u003cp\u003eRoute serial communication wiring separately from high-voltage conductors, motor cables, and high-current switching circuits.\u003c\/p\u003e\n\u003cp\u003eMaintain appropriate cable shielding and terminate shields according to the plant grounding architecture and the connected serial-device requirements.\u003c\/p\u003e\n\u003cp\u003eAvoid creating unintended ground loops through shield connections, especially where equipment receives power from separate distribution points.\u003c\/p\u003e\n\u003cp\u003eConfirm RJ45 connector assignments before connecting field devices because the application serial ports and Ethernet configuration port serve different functions.\u003c\/p\u003e\n\u003cp\u003eConfigure the Modbus node address, communication mode, commands, and data allocation using the applicable ProSoft configuration software.\u003c\/p\u003e\n\u003cp\u003eVerify RTU CRC-16 or ASCII LRC error handling during commissioning by checking the available status counters and error information.\u003c\/p\u003e\n\u003cp\u003eDo not exceed the stated operating temperature, storage temperature, humidity, or installation altitude limits.\u003c\/p\u003e","brand":"AMPHENOL","offers":[{"title":"Default Title","offer_id":43968662700122,"sku":"MVI69E-MBS","price":123.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/MVI69E-MBS2.jpg?v=1788148833","url":"https:\/\/www.plcmasters.com\/products\/prosoft-mvi69e-mbs-modbus-serial-enhanced-communication-module","provider":"PLC Masters Ltd.","version":"1.0","type":"link"}