{"product_id":"prosoft-technology-an-x2-ab-dhrio-ethernet-ip-to-remote-i-o-dh-gateway","title":"ProSoft Technology AN-X2-AB-DHRIO Ethernet\/IP to Remote I\/O \/ DH+ Gateway","description":"\u003ch2\u003eProSoft Technology AN-X2-AB-DHRIO Ethernet\/IP to Remote I\/O \/ DH+ Gateway\u003c\/h2\u003e\n\u003cp\u003eConfigured for protocol conversion between EtherNet\/IP controllers and legacy DH+\/Remote I\/O networks, the \u003cstrong\u003eProSoft Technology AN-X2-AB-DHRIO\u003c\/strong\u003e (\u003cstrong\u003eAN-X2-AB-DHRIO\u003c\/strong\u003e communication gateway) provides direct network data exchange. The gateway supports DH+ messaging and Remote I\/O adapter or scanner functions through Ethernet-based control systems.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eAN-X2-AB-DHRIO\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eProSoft Technology\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eEtherNet\/IP to DH+\/Remote I\/O Communication Gateway\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.71 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temp\u003c\/td\u003e\n\u003ctd\u003e0 deg C to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temp\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to 85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e12 to 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eMaximum 6 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCurrent Consumption\u003c\/td\u003e\n\u003ctd\u003e0.3 A at 24 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Interface\u003c\/td\u003e\n\u003ctd\u003e1 x 10\/100 Base-T, RJ45, auto-crossover\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDH+\/RIO Interfaces\u003c\/td\u003e\n\u003ctd\u003e2 x 3-pin Phoenix removable terminal block connectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDH+ Baud Rates\u003c\/td\u003e\n\u003ctd\u003e57.6, 115.2, 230.4 kbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRIO Baud Rates\u003c\/td\u003e\n\u003ctd\u003e57.6, 115.2, 230.4 kbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMounting\u003c\/td\u003e\n\u003ctd\u003eStandard 35 mm DIN rail\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Rating\u003c\/td\u003e\n\u003ctd\u003eIP20GATEWAY\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStatus Indicators\u003c\/td\u003e\n\u003ctd\u003ePower, Ethernet link\/activity, DH+\/RIO channel status\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration Interface\u003c\/td\u003e\n\u003ctd\u003eBuilt-in web server\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eEtherNet\/IP, DH+ and Remote I\/O Communication\u003c\/h3\u003e\n\u003cp\u003eThe AN-X2-AB-DHRIO provides Ethernet connectivity for data exchange with legacy Allen-Bradley DH+ and Remote I\/O systems.\u003cbr\u003eThe DH+ function supports messaging, programming access, and data transfer between EtherNet\/IP and DH+ networks.\u003cbr\u003eThe Remote I\/O function operates as an adapter or scanner for compatible legacy Remote I\/O architectures.\u003cbr\u003eTwo 3-pin Phoenix terminal connectors provide physical interfaces for the DH+ and Remote I\/O network connections.\u003cbr\u003eThe Ethernet interface uses a 10\/100 Base-T RJ45 port with automatic crossover functionality.\u003cbr\u003eSupported DH+ and RIO communication rates are 57.6, 115.2, and 230.4 kbps.\u003cbr\u003eA built-in web server provides configuration access without requiring dedicated proprietary configuration software.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions (FAQ)\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What power supply does the AN-X2-AB-DHRIO require?\u003c\/strong\u003e\u003cbr\u003eA: The gateway accepts 12 to 24 VDC and consumes a maximum of 6 W.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Which physical network interfaces are provided?\u003c\/strong\u003e\u003cbr\u003eA: The unit provides one RJ45 Ethernet port and two 3-pin Phoenix network connectors.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the gateway directly replace a 1756-DHRIO module?\u003c\/strong\u003e\u003cbr\u003eA: The supplied data identifies the AN-X2-AB-DHRIO as a replacement for the obsolete 1756-DHRIO module.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eMount the gateway on a standard 35 mm DIN rail with adequate enclosure clearance.\u003c\/li\u003e\n\u003cli\u003eConnect a regulated 12 to 24 VDC supply while observing correct polarity and terminal identification.\u003c\/li\u003e\n\u003cli\u003eRoute Ethernet cabling separately from high-voltage power conductors and high-current switching circuits.\u003c\/li\u003e\n\u003cli\u003eUse shielded industrial communication cable where the connected network installation requires electromagnetic interference control.\u003c\/li\u003e\n\u003cli\u003eTerminate cable shields according to the grounding scheme specified for the connected DH+ or RIO network.\u003c\/li\u003e\n\u003cli\u003eKeep DH+ and Remote I\/O wiring physically separated from motor, contactor, and variable-frequency-drive wiring.\u003c\/li\u003e\n\u003cli\u003eVerify the selected DH+ or RIO baud rate against the corresponding network configuration before commissioning.\u003c\/li\u003e\n\u003cli\u003eConfirm Ethernet link and activity indication before testing controller-to-network data exchange.\u003c\/li\u003e\n\u003cli\u003eSecure removable Phoenix terminal blocks before applying power or starting network communication.\u003c\/li\u003e\n\u003cli\u003eConfigure the gateway through its onboard web server and verify communication parameters before connecting production equipment.\u003c\/li\u003e\n\u003cli\u003eDo not apply power outside the specified 12 to 24 VDC input range.\u003c\/li\u003e\n\u003cli\u003eVerify all legacy network terminations and node addressing before migration testing.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"AMPHENOL","offers":[{"title":"Default Title","offer_id":43921310679130,"sku":"AN-X2-AB-DHRIO","price":123.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/AN-X2-AB-DHRIO.jpg?v=1787824159","url":"https:\/\/www.plcmasters.com\/products\/prosoft-technology-an-x2-ab-dhrio-ethernet-ip-to-remote-i-o-dh-gateway","provider":"PLC Masters Ltd.","version":"1.0","type":"link"}