Skip to content
ProSoft Technology MVI56-ADMNET ControlLogix Application Development Module

ProSoft Technology MVI56-ADMNET ControlLogix Application Development Module

  • 16 In stock
  • Manufacturer: AMPHENOL

  • Product No.: MVI56-ADMNET

  • Condition: In stock

  • Product Type: ControlLogix Application Development Module

  • Product Origin: USA

  • Payment:T/T, Western Union

  • Weight: 907g

  • Shipping port: Xiamen

  • Warranty: 12 months

{"id":43931449983066,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"MVI56-ADMNET","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"ProSoft Technology MVI56-ADMNET ControlLogix Application Development Module","public_title":null,"options":["Default Title"],"price":12300,"weight":907,"compare_at_price":32000,"inventory_management":"shopify","barcode":"USA","requires_selling_plan":false,"selling_plan_allocations":[],"quantity_rule":{"min":1,"max":null,"increment":1}}

Description

ProSoft Technology MVI56-ADMNET ControlLogix Application Development Module

Configured for custom Ethernet communication application development in ControlLogix systems, the ProSoft Technology MVI56-ADMNET (MVI56-ADMNET Application Development Module) provides programmable C/C++ execution and configurable serial interfaces for proprietary protocols.

Hardware Specifications

Parameter Specification
Model MVI56-ADMNET
Brand ProSoft Technology
Product Type Programmable Application Development Module
Platform Compatibility Allen-Bradley ControlLogix, 1756 backplane
Application Environment User-programmable C/C++ applications
Processor 32-bit x86 compatible
Flash Memory 512 KB for user applications
Onboard RAM 16 MB
Ethernet Interface 1 x 10/100 Base-T RJ45
Serial Interfaces 2 x configurable RS-232/422/485, RJ45
Backplane Current Load 800 mA @ 5.1 VDC; 3 mA @ 24 VDC
Operating Temp 0 deg C to 60 deg C
Storage Temp -40 deg C to 85 deg C
Relative Humidity 5% to 95%, non-condensing
Weight 2.00 lb
Communication Function Ethernet communication with non-standard or proprietary network protocols

ProSoft Technology Ethernet Application Development

The MVI56-ADMNET provides an in-rack execution environment for custom communication applications within a ControlLogix chassis.

Its Ethernet interface uses a 10/100 Base-T RJ45 connection for external network communication.

Two configurable serial ports support RS-232, RS-422, and RS-485 electrical interfaces for device communication and debugging.

The onboard 32-bit x86 compatible processor executes user-developed applications stored in dedicated flash memory.

The module also provides 16 MB of onboard RAM for application execution and runtime data handling.

For ControlLogix integration, the module receives backplane power through the 1756 chassis interface.

The specified backplane current load is 800 mA at 5.1 VDC and 3 mA at 24 VDC.

Frequently Asked Questions (FAQ)

Q: Which ControlLogix interface does the MVI56-ADMNET use?
A: The module interfaces with the Allen-Bradley ControlLogix system through the 1756 backplane.

Q: What serial communication standards are supported?
A: Two RJ45 serial ports can be configured for RS-232, RS-422, or RS-485 operation.

Q: Can the module execute custom communication software?
A: Yes. The module provides a 32-bit x86 compatible processor, 512 KB flash memory, and 16 MB RAM for user applications.

Field Installation Guidelines

Install the module in a compatible ControlLogix 1756 chassis according to the applicable chassis and module installation procedures.

Verify the available chassis power budget against the specified 5.1 VDC and 24 VDC backplane current loads before installation.

Use shielded communication cabling where required by the connected Ethernet or serial equipment and the site wiring standard.

Route Ethernet and serial communication cables separately from high-current motor, contactor, and variable-frequency-drive wiring.

Terminate cable shields according to the equipment grounding architecture and avoid creating unintended ground loops.

Verify RS-232, RS-422, or RS-485 configuration before connecting field devices, because the electrical interface determines the applicable wiring topology.

Confirm RJ45 connector pin assignments before applying power or connecting external serial equipment.

Maintain suitable separation between communication wiring and sources of electromagnetic interference during cabinet installation.

Verify operating temperature, humidity, and storage requirements against the actual installation environment.

Features

We welcome bulk orders and have a minimum order quantity of just one unit.

Upon request, we can provide all necessary documentation, including Certificates of Origin/Conformance and other required export documents.

For items in stock, we aim to deliver within 1-3 days after payment confirmation. Items with specified lead times will be delivered according to the quoted schedule.

We accept 100% T/T (Telegraphic Transfer) payment before shipping. For items with lead times, a 30% deposit is required upfront, with the remaining 70% due before shipment. For RMB transfers, please contact us if you have an agent in China.

We offer a standard one-year warranty on all new and original items. If you require an extended warranty, please contact us for additional cost details.

Your satisfaction is important to us. If you need to return an item, it must be done within 30 days of the order date. The product must be unused, unopened, and in its original packaging with all accessories included. Refunds are processed within 5-7 business days after we receive the returned item. Please note that shipping and related charges are non-refundable.