Description
Configured for DNP 3.0 serial communication in CompactLogix control platforms, the ProSoft Technology MVI69-DNPPS (MVI69-DNP Communication Module) provides direct protocol execution between Rockwell Automation 1769 backplane systems and DNP 3.0 master or slave networks.
Hardware Specifications
| Parameter | Specification |
|---|---|
| Model | MVI69-DNP / MVI69-DNPPS |
| Brand | ProSoft Technology |
| Product Type | DNP 3.0 Communication Modules |
| Platform Compatibility | Allen-Bradley CompactLogix 1769 systems and MicroLogix 1500 |
| Origin | USA |
| Operating Temp | 0 deg C to 60 deg C |
| Power Consumption | 800 mA @ 5 VDC backplane current load |
| Communication Protocol | DNP 3.0 (Distributed Network Protocol) |
| Serial Interfaces | 2 x configurable RS-232 / RS-422 / RS-485 ports |
| Baud Rate Range | 110 bps to 115.2 kbps |
| Operating Modes | Configurable DNP 3.0 Master or Slave mode |
| Event Processing | Class 1, Class 2, Class 3 event generation with time synchronization |
| Network Integration | In-rack communication through 1769 CompactLogix backplane |
Protocol Conversion and Industrial Network Integration
The MVI69-DNP module performs independent DNP 3.0 protocol processing while exchanging controller data through CompactLogix I/O data transfers. The module supports master and slave communication roles, allowing direct serial connection with SCADA systems, RTUs, and intelligent electronic devices.
Furthermore, the module provides configurable RS-232, RS-422, and RS-485 interfaces for serial network adaptation. DNP event handling includes Class 1, Class 2, and Class 3 event reporting with synchronized timestamps for monitored field data.
The ProSoft Technology communication architecture includes protocol conversion without requiring an external gateway device. The module communicates through the 1769 rack backplane and maintains data exchange between the processor and external DNP networks.
Protocol Conversion and Backplane Communication Features
The MVI69-DNP uses CompactLogix backplane bus communication for controller-side data transfer. The module firmware manages DNP 3.0 framing, message processing, and serial communication functions independently from the main controller scan execution.
The communication interface supports deterministic data exchange between Rockwell Automation PLC platforms and external serial devices. Configuration parameters define port operation, communication mode, and DNP data handling behavior.
The module supports firmware flash compatibility for maintaining communication functions within supported CompactLogix system configurations. Installation requires matching module firmware and controller platform requirements before system commissioning.
Frequently Asked Questions
Q: Does the MVI69-DNP require an external protocol converter for DNP 3.0 communication?
A: No. The module performs DNP 3.0 protocol processing internally and connects directly to supported CompactLogix 1769 I/O systems.
Q: Which serial electrical interfaces are available on the module?
A: The module provides two configurable serial ports supporting RS-232, RS-422, and RS-485 communication standards.
Q: How does the module exchange data with the CompactLogix processor?
A: The module exchanges data through standard 1769 backplane I/O transfers while independently managing DNP communication tasks.
Field Installation Guidelines
Install the MVI69-DNP module into a compatible 1769 CompactLogix rack following the controller manufacturer's slot installation requirements.
Verify that the backplane power supply capacity supports the module current demand before system startup. Connect serial communication wiring according to the selected RS-232, RS-422, or RS-485 interface configuration.
Use shielded communication cables for serial networks and terminate cable shields according to the site grounding practice. Separate communication wiring from high-voltage power conductors and high-current switching circuits to reduce electrical interference.
Confirm port configuration, baud rate settings, and DNP addressing parameters before connecting field devices. Perform communication testing between the PLC processor, module, and external DNP devices before placing the system into operational service.
Features
We welcome bulk orders and have a minimum order quantity of just one unit.
Upon request, we can provide all necessary documentation, including Certificates of Origin/Conformance and other required export documents.
For items in stock, we aim to deliver within 1-3 days after payment confirmation. Items with specified lead times will be delivered according to the quoted schedule.
We accept 100% T/T (Telegraphic Transfer) payment before shipping. For items with lead times, a 30% deposit is required upfront, with the remaining 70% due before shipment. For RMB transfers, please contact us if you have an agent in China.
We offer a standard one-year warranty on all new and original items. If you require an extended warranty, please contact us for additional cost details.
Your satisfaction is important to us. If you need to return an item, it must be done within 30 days of the order date. The product must be unused, unopened, and in its original packaging with all accessories included. Refunds are processed within 5-7 business days after we receive the returned item. Please note that shipping and related charges are non-refundable.