{"product_id":"prosoft-technology-mvi69e-mbtcp-modbus-tcp-ip-enhanced-communication-module","title":"ProSoft Technology MVI69E-MBTCP Modbus TCP\/IP Enhanced Communication Module","description":"\u003ch2\u003eProSoft Technology MVI69E-MBTCP Modbus TCP\/IP Enhanced Communication Module\u003c\/h2\u003e\n\u003cp\u003eConfigured for Modbus TCP\/IP data exchange in 1769 CompactLogix systems, the \u003cstrong\u003eProSoft Technology MVI69E-MBTCP\u003c\/strong\u003e (\u003cstrong\u003eMVI69E-MBTCP\u003c\/strong\u003e Modbus TCP\/IP Enhanced Communication Module) provides one RJ45 Ethernet interface, 20 Modbus client connections, and up to 10,000 words of application data.\u003c\/p\u003e\n\u003ch3\u003eHardware Specifications\u003c\/h3\u003e\n\u003cfigure\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eMVI69E-MBTCP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBrand\u003c\/td\u003e\n\u003ctd\u003eProSoft Technology\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Type\u003c\/td\u003e\n\u003ctd\u003eModbus TCP\/IP Enhanced Communication Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Line\u003c\/td\u003e\n\u003ctd\u003eCompactLogix\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Rack\u003c\/td\u003e\n\u003ctd\u003e1769 CompactLogix\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModule Width\u003c\/td\u003e\n\u003ctd\u003eSingle slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Port\u003c\/td\u003e\n\u003ctd\u003e1 x RJ45 Ethernet\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEthernet Data Rate\u003c\/td\u003e\n\u003ctd\u003e10 \/ 100 Mbps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAvailable Data\u003c\/td\u003e\n\u003ctd\u003e10,000 words\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eI\/O Size\u003c\/td\u003e\n\u003ctd\u003e60 \/ 120 \/ 240 x 16-bit integers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModbus Client Connections\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommands per Client Connection\u003c\/td\u003e\n\u003ctd\u003e16 maximum\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFloating Point Data\u003c\/td\u003e\n\u003ctd\u003eSupported, including configurable Enron, Daniel, and other implementations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackplane Current Load\u003c\/td\u003e\n\u003ctd\u003e500 mA at 5.1 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e500 mA at 5 VDC, communication module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply Distance Rating\u003c\/td\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration Software\u003c\/td\u003e\n\u003ctd\u003eProSoft Configuration Builder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLED Indicators\u003c\/td\u003e\n\u003ctd\u003eConfiguration Status, Application Status, Backplane Connectivity Status, Module Status\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e0 deg C to 60 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-40 deg C to 85 deg C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative Humidity\u003c\/td\u003e\n\u003ctd\u003e5% to 95%, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Shock\u003c\/td\u003e\n\u003ctd\u003e30 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.06 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/figure\u003e\n\u003ch3\u003eProtocol Conversion and Ethernet Interface\u003c\/h3\u003e\n\u003cp\u003eThe MVI69E-MBTCP exchanges Modbus TCP\/IP data through one 10\/100 Mbps RJ45 Ethernet interface. The module occupies one CompactLogix chassis slot and communicates with the controller through the 1769 backplane.\u003c\/p\u003e\n\u003cp\u003eThe module supports up to 20 Modbus client connections, with a maximum of 16 commands configured for each client connection. Floating point movement supports configurable Enron, Daniel, and other implementation formats.\u003c\/p\u003e\n\u003cp\u003eApplication data capacity reaches 10,000 words, while configurable I\/O sizes include 60, 120, or 240 16-bit integers. Therefore, application mapping should match the configured data size before controller integration.\u003c\/p\u003e\n\u003cp\u003eThe module uses ProSoft Configuration Builder for configuration. LED indicators provide separate status information for configuration, application operation, backplane connectivity, and module status.\u003c\/p\u003e\n\u003cp\u003eFor protocol conversion, Ethernet packet handling and Modbus command processing remain dependent on the configured client connections and command structure. Network segmentation should therefore account for the expected Modbus transaction load.\u003c\/p\u003e\n\u003ch3\u003eFrequently Asked Questions\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the MVI69E-MBTCP provide a built-in Ethernet connection?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes. The module provides one RJ45 interface supporting 10 \/ 100 Mbps Ethernet communication.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: How much backplane current does the module require?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e The supplied specification lists 500 mA at 5.1 VDC for the backplane current load.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can the module handle floating point Modbus data?\u003c\/strong\u003e\u003cbr\u003e\u003cstrong\u003eA:\u003c\/strong\u003e Yes. Floating point data movement is supported, including configurable Enron, Daniel, and other implementations.\u003c\/p\u003e\n\u003ch3\u003eField Installation Guidelines\u003c\/h3\u003e\n\u003cp\u003eInstall the module only in a compatible 1769 CompactLogix chassis and verify available backplane current capacity before energization.\u003c\/p\u003e\n\u003cp\u003eInsert the module into the designated single-slot position and confirm mechanical engagement with the chassis backplane connector.\u003c\/p\u003e\n\u003cp\u003eConnect the Ethernet cable to the RJ45 interface without applying excessive mechanical force to the connector or module housing.\u003c\/p\u003e\n\u003cp\u003eRoute Ethernet communication wiring separately from high-voltage power conductors and high-current switching circuits where practical.\u003c\/p\u003e\n\u003cp\u003eUse appropriate industrial Ethernet cabling for the installation environment and maintain cable routing practices that limit electromagnetic interference.\u003c\/p\u003e\n\u003cp\u003eTerminate cable shielding according to the plant grounding standard and avoid creating unintended shield-current paths between equipment cabinets.\u003c\/p\u003e\n\u003cp\u003eBefore commissioning, configure the module with ProSoft Configuration Builder and verify the Modbus client connection count and command assignments.\u003c\/p\u003e\n\u003cp\u003eConfirm the configured I\/O size and application data mapping against the CompactLogix controller program before placing the communication path into service.\u003c\/p\u003e\n\u003cp\u003eVerify configuration, application, backplane, and module status indicators after startup. Investigate abnormal indications before enabling dependent control sequences.\u003c\/p\u003e\n\u003cp\u003eDo not exceed the specified operating temperature, humidity, shock, or backplane current conditions during field operation.\u003c\/p\u003e","brand":"AMPHENOL","offers":[{"title":"Default Title","offer_id":43931377336410,"sku":"MV169E-MBTCP","price":123.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/MV169E-MBTCP2.jpg?v=1787902398","url":"https:\/\/www.plcmasters.com\/products\/prosoft-technology-mvi69e-mbtcp-modbus-tcp-ip-enhanced-communication-module","provider":"PLC Masters Ltd.","version":"1.0","type":"link"}