ProSoft Technology PLX31-EIP-MBTCP EtherNet/IP to Modbus TCP/IP Gateway

ProSoft Technology PLX31-EIP-MBTCP EtherNet/IP to Modbus TCP/IP Gateway

  • 16 In stock
  • Manufacturer: AMPHENOL

  • Product No.: PLX31-EIP-MBTCP

  • Condition: In stock

  • Product Type: EtherNet/IP to Modbus TCP/IP Gateway

  • Product Origin: USA

  • Payment:T/T, Western Union

  • Weight: 907g

  • Shipping port: Xiamen

  • Warranty: 12 months

{"id":43968913014874,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"PLX31-EIP-MBTCP","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"ProSoft Technology PLX31-EIP-MBTCP EtherNet\/IP to Modbus TCP\/IP Gateway","public_title":null,"options":["Default Title"],"price":12300,"weight":907,"compare_at_price":32000,"inventory_management":"shopify","barcode":"USA","requires_selling_plan":false,"selling_plan_allocations":[],"quantity_rule":{"min":1,"max":null,"increment":1}}

Description

ProSoft Technology PLX31-EIP-MBTCP EtherNet/IP to Modbus TCP/IP Gateway

Configured for bidirectional protocol conversion between EtherNet/IP and Modbus TCP/IP networks, the ProSoft Technology PLX31-EIP-MBTCP (PLX31-EIP-MBTCP communication gateway) provides direct Ethernet data exchange between industrial controllers and Modbus TCP/IP devices.

Hardware Specifications

Parameter Specification
Model PLX31-EIP-MBTCP
Brand ProSoft Technology
Weight 2.00 lb
Operating Temp -25 deg C to +70 deg C
Storage Temperature -40 deg C to +85 deg C
Power Consumption 24 VDC @ 200 mA; 10 to 30 VDC @ 400 mA max
Power Supply 10 to 30 VDC
Ethernet Ports 2 x RJ45, 10/100 Mbps, Auto-MDI/MDI-X, shared IP address
Protocols EtherNet/IP and Modbus TCP/IP
Mounting Standard 35 mm DIN rail
Enclosure Rating IP20
Relative Humidity 5% to 95% RH, non-condensing
Vibration 5 g @ 10 to 150 Hz
Operational Shock 30 g
Configuration ProSoft Configuration Builder
Controller Integration Studio 5000 / RSLogix 5000 AOP and AOI
Data Storage SD card configuration backup
Hazardous Area Rating UL/cUL Class 1 Div. 2, ATEX Zone 2

Protocol Conversion and Network Interface

The PLX31-EIP-MBTCP exchanges mapped data between EtherNet/IP controllers and Modbus TCP/IP devices without custom ladder logic for protocol translation. Its two RJ45 Ethernet ports share one IP address, supporting network daisy-chaining while maintaining a single logical Ethernet interface.

The gateway supports EtherNet/IP integration with Rockwell Automation ControlLogix and CompactLogix controllers through Add-On Profiles and Add-On Instructions. ProSoft Configuration Builder provides configuration and diagnostic functions, while the SD card supports local configuration backup for replacement procedures.

Frequently Asked Questions (FAQ)

Q: Can both Ethernet ports use separate IP addresses?
A: No. The supplied specifications identify both RJ45 ports as sharing a single IP address.

Q: What DC supply range does the gateway accept?
A: The specified supply range is 10 to 30 VDC, with a maximum current load of 400 mA.

Q: Is the gateway suitable for DIN-rail installation?
A: Yes. The specified mounting method is a standard 35 mm DIN rail.

Field Installation Guidelines

  • Mount the gateway securely on a standard 35 mm DIN rail inside an enclosure appropriate for the specified IP20 protection level.
  • Provide a regulated DC supply within the specified 10 to 30 VDC operating range.
  • Size the DC power wiring for the specified maximum current load and protect the supply according to the control-panel design.
  • Route Ethernet cables separately from high-voltage power wiring and high-current switching conductors where practical.
  • Use shielded Ethernet cabling where the installation environment requires additional electromagnetic-noise control.
  • Bond cable shields according to the site's industrial grounding scheme and avoid unintended ground-current paths.
  • Verify the shared-IP architecture before assigning the gateway address and connecting both Ethernet ports.
  • Back up the gateway configuration to the SD card after commissioning and retain the configuration with the panel documentation.
  • Confirm EtherNet/IP controller mappings and Modbus TCP/IP register mappings before placing the gateway into service.
  • For hazardous-area installations, verify that the complete installation satisfies the applicable UL/cUL Class 1 Div. 2 or ATEX Zone 2 requirements.

Features

We welcome bulk orders and have a minimum order quantity of just one unit.

Upon request, we can provide all necessary documentation, including Certificates of Origin/Conformance and other required export documents.

For items in stock, we aim to deliver within 1-3 days after payment confirmation. Items with specified lead times will be delivered according to the quoted schedule.

We accept 100% T/T (Telegraphic Transfer) payment before shipping. For items with lead times, a 30% deposit is required upfront, with the remaining 70% due before shipment. For RMB transfers, please contact us if you have an agent in China.

We offer a standard one-year warranty on all new and original items. If you require an extended warranty, please contact us for additional cost details.

Your satisfaction is important to us. If you need to return an item, it must be done within 30 days of the order date. The product must be unused, unopened, and in its original packaging with all accessories included. Refunds are processed within 5-7 business days after we receive the returned item. Please note that shipping and related charges are non-refundable.