{"product_id":"schneider-170aai14000-distributed-analog-input-module","title":"Schneider 170AAI14000 Distributed Analog Input Module","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSchneider 170AAI14000\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a high-performance distributed analog input module for the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eModicon Momentum\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eautomation platform. It provides\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e16 single-ended analog input channels\u003c\/strong\u003e, supporting both\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003evoltage and current\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esignal types. This module is ideal for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003edistributed control systems\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eindustrial automation\u003c\/strong\u003e, where accurate and rapid analog signal acquisition is essential. It features\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ereverse polarity protection\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eslow-blow fuse protection\u003c\/strong\u003e, and a\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003efast 25 ms update time\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eto ensure\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003estable and safe operations\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ein harsh environments.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003ch4\u003eGeneral Information\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel Number\u003c\/strong\u003e:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e170AAI14000\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e: Distributed Analog Input Module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePlatform Compatibility\u003c\/strong\u003e: Modicon Momentum series\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNumber of Analog Inputs\u003c\/strong\u003e: 16\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Type\u003c\/strong\u003e: Single-ended\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Signal Type\u003c\/strong\u003e: Voltage or current (configurable)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eAnalog Input Ranges\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e±10 V\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(12-bit + sign, \u0026gt; 2200 kΩ)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e±5 V\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(12-bit + sign, \u0026gt; 2200 kΩ)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e4...20 mA\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(12-bit, \u0026lt; 0.25 Ω)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Filter\u003c\/strong\u003e: 10 kHz low-pass filter\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eAccuracy and Performance\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eData Format\u003c\/strong\u003e: 16-bit signed\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUpdate Time\u003c\/strong\u003e: 25 milliseconds\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAccuracy at 25°C\u003c\/strong\u003e:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e±0.15% (±10 V \/ ±5 V)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e±0.25% (4...20 mA)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAccuracy at 60°C\u003c\/strong\u003e:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e±0.25% (±10 V \/ ±5 V)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e±0.45% (4...20 mA)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Drift at 60°C\u003c\/strong\u003e:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e±30 %oFS\/°C (voltage)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e±60 %oFS\/°C (current)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eElectrical Characteristics\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIsolation (Channel-to-Ground)\u003c\/strong\u003e: 1780 V AC for 1 min\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIsolation (Supply-to-Ground)\u003c\/strong\u003e: 500 V AC for 1 min\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCommon Mode Voltage\u003c\/strong\u003e:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e100 V DC, 47...63 Hz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e250 V AC, 47...63 Hz\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eExternal Power Requirement\u003c\/strong\u003e: ±30 V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCurrent Consumption\u003c\/strong\u003e: 305 mA at 24 V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMax Power Dissipation\u003c\/strong\u003e: 5.55 W\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eProtection and Safety\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eReverse Polarity Protection\u003c\/strong\u003e: Internal\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProtection Type\u003c\/strong\u003e: Internal 2 A slow-blow fuse\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAssociated Fuse Rating\u003c\/strong\u003e: 500 mA fast-blow\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCertifications\u003c\/strong\u003e: CE, UL, CSA, FM Class 1 Division 2\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eIndicators and Connections\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLEDs\u003c\/strong\u003e: 16 channel status LEDs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical Connections\u003c\/strong\u003e: 2 removable terminal blocks\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eMechanical Dimensions\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWidth\u003c\/strong\u003e: 141.5 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHeight\u003c\/strong\u003e: 125 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDepth\u003c\/strong\u003e: 47.5 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e: 0.215 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eEnvironmental Ratings\u003c\/h4\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: 0 to 60 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e: -40 to 85 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRelative Humidity\u003c\/strong\u003e: 95% non-condensing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMax Altitude\u003c\/strong\u003e: ≤ 5000 m\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eElectrostatic Discharge\u003c\/strong\u003e:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e4 kV contact (IEC 801-2)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e8 kV air (IEC 801-2)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eElectromagnetic Immunity\u003c\/strong\u003e: 10 V\/m (IEC 801-3)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":42027347345498,"sku":"170AAI14000","price":169.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/170AAI14000.jpg?v=1751434725","url":"https:\/\/www.plcmasters.com\/products\/schneider-170aai14000-distributed-analog-input-module","provider":"PLC Masters Ltd.","version":"1.0","type":"link"}