{"product_id":"schneider-bmxcps4022s-dc-power-supply-module","title":"Schneider BMXCPS4022S DC Power Supply Module","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSchneider Electric BMXCPS4022S\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a safety-rated redundant DC power supply for the Modicon X80 platform. It delivers stable and efficient power in demanding industrial environments. The module supports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e24–48V DC input\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand provides\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e40W at 24V DC\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e18W at 3.3V DC\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoutputs. Its robust design ensures continuous operation and advanced diagnostics for high-availability automation systems. This power supply operates reliably in harsh conditions, featuring\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eATEX Zone 2\/22\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIECEx Zone 2\/22\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecertifications. Its compact and rugged form ensures durability under vibration, shock, and extreme temperature conditions.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eGeneral Information\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Family:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eModicon X80\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Type:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ePower supply module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eBackplane Compatibility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAll Modicon X80 backplanes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDiagnostics:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAdvanced redundancy status and voltage monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical Characteristics\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Voltage Range:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e24–48 V DC (limits: 18–62.4 V)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput Power:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e40 W at 24 V DC; 18 W at 3.3 V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Current:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e1.9 A at 24 V; 1 A at 48 V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInrush Current:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e60 A (24 V and 48 V)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Dissipation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMaximum 8.5 W\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMTBF Reliability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e721,000 hours\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eProtection and Safety\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProtection Types:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eInternal fuse (inaccessible), overload, overvoltage, and short-circuit protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eControl Feature:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eRESET button for cold start\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStatus Indicators:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eGreen LEDs for voltage, redundancy, and power status\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCertifications:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eCE, UL, CSA, RCM, EAC, Marine, TÜV, ATEX, IECEx\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmental Conditions\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e-25 to +60 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStorage Temperature:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e-40 to +85 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRelative Humidity:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e5–95% at 55 °C (non-condensing)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAltitude:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0–2000 m; 2000–5000 m with derating\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProtection Treatment:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eConformal coating (three-proof protection)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIngress Protection:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIP20\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInsulation Resistance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e≥100 MΩ (primary\/secondary and ground)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWithstand Voltage:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e1500 V (primary\/secondary and ground)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eResistance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eGas class Gx (ISA S71.04), dust class 3S4, mold class 3B2, salt resistance class 2\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical Data\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNet Weight:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0.81 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eShock Resistance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e15 gn\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVibration Resistance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e3 gn\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum Cable Distance:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e10–15 m\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eConnectors:\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e5-pin connector for line power and protective earth\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e2-pin connector for alarm relay\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCompliance Standards\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIEC 61131-2\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(Programmable Controllers)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIEC 61010-2-201\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eCSA C22.2 No 61010-2-201\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEN\/IEC 61000-6-5\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(industrial electromagnetic compatibility)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eEN\/IEC 61850-3\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(substation environment)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIEC 60079-0\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(explosive atmosphere compliance)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":42440232075354,"sku":"BMXCPS4022S","price":182.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/BMXCPS4022S2.jpg?v=1760426981","url":"https:\/\/www.plcmasters.com\/products\/schneider-bmxcps4022s-dc-power-supply-module","provider":"PLC Masters Ltd.","version":"1.0","type":"link"}