{"product_id":"allen-bradley-1756-irt8i-a-controllogix-rtd-thermocouple-input-module","title":"Módulo de Entrada RTD\/Termopar Allen-Bradley 1756-IRT8I\/A ControlLogix","description":"\u003ch1 class=\"PDq2pG_selectionAnchorContainer\"\u003eMódulo de Entrada RTD\/Termopar Allen-Bradley 1756-IRT8I\/A ControlLogix\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003cp\u003eO\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley 1756-IRT8I\/A\u003c\/strong\u003e, também catalogado como o\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e1756-IRT8I\/A\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emódulo de entrada analógica RTD\/termopar, opera como um componente de hardware dedicado para aquisição de sinais de temperatura em sistemas I\/O do backplane ControlLogix. Configurado para conversão RTD e termopar em redes ControlLogix, o\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley 1756-IRT8I\/A (módulo de entrada de temperatura 1756-IRT8I\/A)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efornece medição elétrica direta da resistência e saídas de sensor em nível de milivolts através de 8 canais isolados individualmente.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eDesdobramento do Sufixo \u0026amp; Matriz do Modelo\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e1756\u003c\/strong\u003e: Plataforma I\/O baseada em chassis ControlLogix\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIRT8\u003c\/strong\u003e: Estrutura de entrada RTD \/ termopar de 8 canais\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eI\u003c\/strong\u003e: Arquitetura de entrada isolada individualmente\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\/A\u003c\/strong\u003e: Identificador de revisão de hardware\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eNenhuma segmentação adicional de variante está definida no conjunto de dados fornecido.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEspecificações de Hardware\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParâmetro\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eEspecificação\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModelo\u003c\/td\u003e\n\u003ctd\u003e1756-IRT8I\/A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMarca\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeso\u003c\/td\u003e\n\u003ctd\u003e1,00 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConsumo de Energia\u003c\/td\u003e\n\u003ctd\u003e4,6 W (backplane)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNúmero de Entradas\u003c\/td\u003e\n\u003ctd\u003e8 canais de entrada de temperatura isolados\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTipos de Sinal\u003c\/td\u003e\n\u003ctd\u003eRTD (2, 3, 4 fios), Termopares (J, K, T, E, R, S, B, N)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntervalo de Resistência de Entrada\u003c\/td\u003e\n\u003ctd\u003e1 a 500 Ohms \/ 2 a 1000 Ohms \/ 4 a 2000 Ohms \/ 8 a 400 Ohms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntervalo de Entrada mV\u003c\/td\u003e\n\u003ctd\u003e-100 a 100 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolução\u003c\/td\u003e\n\u003ctd\u003e15 bits + sinal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrecisão\u003c\/td\u003e\n\u003ctd\u003e±0,1% da escala total\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompensação de Junção Fria\u003c\/td\u003e\n\u003ctd\u003eIncorporado (2 sensores)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolamento\u003c\/td\u003e\n\u003ctd\u003eIsolamento entre canais\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTensão de Isolamento Contínuo\u003c\/td\u003e\n\u003ctd\u003e250 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConsumo de Corrente no Backplane\u003c\/td\u003e\n\u003ctd\u003e~200 mA a 5,1 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConsumo de Corrente 24 VDC\u003c\/td\u003e\n\u003ctd\u003e~150 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDissipação Térmica\u003c\/td\u003e\n\u003ctd\u003e15,7 BTU\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMétodo de Conversão\u003c\/td\u003e\n\u003ctd\u003eSigma-Delta\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTempo Mínimo de Varredura\u003c\/td\u003e\n\u003ctd\u003e1 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTipo de Conector\u003c\/td\u003e\n\u003ctd\u003eMódulo de interface RTB de 36 pinos ou 1492 IFM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertificações\u003c\/td\u003e\n\u003ctd\u003eAprovações UL, CE, CSA, para locais perigosos\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eComportamento Determinístico de Aquisição de Temperatura no Backplane ControlLogix\u003c\/h3\u003e\n\u003cp\u003eO 1756-IRT8I\/A executa a conversão sigma-delta por canal antes da publicação dos dados no backplane ControlLogix. Os valores de temperatura derivados da resistência RTD ou da entrada de milivolts do termopar são normalizados em unidades de engenharia no firmware do módulo antes da transferência cíclica para a memória do controlador.\u003c\/p\u003e\n\u003cp\u003eO isolamento entre canais mantém a separação elétrica entre tipos de sensores mistos durante a amostragem simultânea. A compensação da junção fria é executada internamente usando sensores de referência duplos, garantindo a correção da FEM do termopar independente da variação de temperatura do bloco terminal.\u003c\/p\u003e\n\u003cp\u003eO tempo de varrimento do backplane é governado pela configuração da ranhura do chassis e pela taxa de tarefa do controlador, com capacidade mínima de varrimento de entrada do módulo até 1 ms sob configuração otimizada.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003ePerguntas Frequentes (FAQ)\u003c\/h3\u003e\n\u003cp\u003eP: É possível misturar entradas RTD e termopar no mesmo módulo?\u003cbr\u003eR: Sim. Cada um dos 8 canais suporta configuração independente para tipos de entrada RTD ou termopar, permitindo a utilização mista de sensores num único módulo.\u003c\/p\u003e\n\u003cp\u003eP: Como o isolamento entre canais afeta a estabilidade da medição de temperatura?\u003cbr\u003eR: O isolamento entre canais impede a interação elétrica entre os circuitos dos sensores, reduzindo o desvio de medição causado por diferenças de potencial de terra ou caminhos de retorno partilhados.\u003c\/p\u003e\n\u003cp\u003eP: Qual é o papel da compensação da junção fria neste módulo?\u003cbr\u003eR: O módulo utiliza dois sensores internos CJC para corrigir a tensão da junção do termopar, compensando variações de temperatura no terminal RTB antes da digitalização.\u003c\/p\u003e\n\u003chr\u003e\u003chr\u003e\n\u003ch3\u003eDiretrizes para Instalação em Campo\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eInstale o módulo numa ranhura compatível do chassis 1756 ControlLogix com a alimentação do sistema desligada ou conforme procedimento de inserção aprovado\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAssegure que o conector RTB ou 1492 IFM está totalmente encaixado antes de energizar a fiação de campo\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUse fiação de par trançado blindado para entradas de termopar; termine a blindagem apenas numa extremidade\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMantenha separação entre a fiação do sensor de baixo nível em milivolts e os condutores de alta tensão para reduzir ruído induzido\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVerifique a configuração correta do tipo de sensor (RTD ou termopar) antes da energização do circuito\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEvite exceder o intervalo de entrada especificado (resistência ou mV) durante a comissionamento para prevenir erros de conversão\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":43602602033242,"sku":"1756-IRT8I\/A","price":123.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/1756-IRT8IA2.jpg?v=1783319771","url":"https:\/\/www.plcmasters.com\/pt\/products\/allen-bradley-1756-irt8i-a-controllogix-rtd-thermocouple-input-module","provider":"PLC Masters Ltd.","version":"1.0","type":"link"}