{"product_id":"allen-bradley-1756-it6i-controllogix-thermocouple-input-module","title":"Módulo de Entrada de Termopar Allen-Bradley 1756-IT6I ControlLogix","description":"\u003ch1 class=\"PDq2pG_selectionAnchorContainer\"\u003eMódulo de Entrada de Termopar Allen-Bradley 1756-IT6I ControlLogix\u003cspan class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h1\u003e\n\u003cp\u003eO\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley 1756-IT6I\u003c\/strong\u003e, também catalogado como o\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emódulo de entrada analógica de termopar 1756-IT6I\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e, serve como um dedicado\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003emódulo de entrada de temperatura ControlLogix\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eutilizado para executar aquisição isolada de sinais de termopar e milivolt em sistemas backplane ControlLogix. Configurado para conversão direta de sinais EMF de baixo nível, o\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eAllen-Bradley 1756-IT6I (módulo de entrada de termopar 1756-IT6I)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efornece seis caminhos de medição eletricamente isolados com compensação interna CJC para correção de referência de temperatura.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eDesdobramento do Sufixo \u0026amp; Matriz de Modelos\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e1756\u003c\/strong\u003e: Plataforma I\/O do chassis ControlLogix\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIT6\u003c\/strong\u003e: Estrutura de entrada de termopar \/ milivolt de 6 pontos\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eI\u003c\/strong\u003e: Arquitetura de entrada isolada individualmente\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003e\/I ou A\u003c\/strong\u003e: Identificador de revisão de hardware (não totalmente especificado no conjunto de dados)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eNenhuma variante funcional adicional está definida nos dados fornecidos.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003eEspecificações de Hardware\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth class=\"last:pe-10\"\u003eParâmetro\u003c\/th\u003e\n\u003cth class=\"last:pe-10\"\u003eEspecificação\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModelo\u003c\/td\u003e\n\u003ctd\u003e1756-IT6I\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMarca\u003c\/td\u003e\n\u003ctd\u003eAllen-Bradley\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeso\u003c\/td\u003e\n\u003ctd\u003e1,38 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperatura de Operação\u003c\/td\u003e\n\u003ctd\u003e0 a 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConsumo de Energia\u003c\/td\u003e\n\u003ctd\u003e4,3 W máx.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNúmero de Entradas\u003c\/td\u003e\n\u003ctd\u003e6 canais isolados de termopar\/mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTermopares Suportados\u003c\/td\u003e\n\u003ctd\u003eB, C, E, J, K, N, R, S, T, L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTipo de Entrada\u003c\/td\u003e\n\u003ctd\u003eTermopar \/ milivolt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolução\u003c\/td\u003e\n\u003ctd\u003e16 bits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFaixa de Entrada\u003c\/td\u003e\n\u003ctd\u003e-12 a 78 mV (modos de ponto flutuante)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensor CJC\u003c\/td\u003e\n\u003ctd\u003e1 canal interno de compensação de junção fria\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCorrente do Backplane (5 VDC)\u003c\/td\u003e\n\u003ctd\u003e250 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCorrente do Backplane (24 VDC)\u003c\/td\u003e\n\u003ctd\u003e125 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTempo de Varredura do Módulo\u003c\/td\u003e\n\u003ctd\u003e10 ms a 50 ms dependendo do formato de dados\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFormato de Dados\u003c\/td\u003e\n\u003ctd\u003eInteiro (complemento de 2), ponto flutuante IEEE de 32 bits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsolamento\u003c\/td\u003e\n\u003ctd\u003eIsolamento entre canais\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBlocos de Terminais\u003c\/td\u003e\n\u003ctd\u003e1756-TBNH, 1756-TBSH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface do Backplane\u003c\/td\u003e\n\u003ctd\u003eBarramento do chassis ControlLogix\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertificações\u003c\/td\u003e\n\u003ctd\u003eUL, CE, CSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003chr\u003e\n\u003ch3\u003eComportamento Determinístico de Aquisição de Termopar no Backplane ControlLogix\u003c\/h3\u003e\n\u003cp\u003eO 1756-IT6I executa condicionamento de sinal baseado em sigma-delta antes da transferência de dados pelo backplane ControlLogix. Os sinais EMF do termopar e as entradas em milivolts são digitalizados por canal e mapeados em representações inteiras ou em ponto flutuante IEEE de 32 bits, dependendo da configuração.\u003c\/p\u003e\n\u003cp\u003eO isolamento dos canais assegura domínios de medição independentes, prevenindo interação de loops de terra entre as junções dos termopares. A compensação da junta fria é realizada usando um canal de referência dedicado para corrigir a deriva da temperatura do terminal antes da conversão de escala.\u003c\/p\u003e\n\u003cp\u003eA troca de dados no backplane é sincronizada com os ciclos de varrimento do chassis, com tempo mínimo de varrimento de 10 ms no modo inteiro para aquisição em milivolts e ciclos estendidos até 50 ms no modo de conversão de temperatura em ponto flutuante.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch3\u003ePerguntas Frequentes (FAQ)\u003c\/h3\u003e\n\u003cp\u003eP: É possível misturar todos os tipos de termopar no mesmo módulo?\u003cbr\u003eR: Sim. Cada um dos seis canais pode ser configurado individualmente para diferentes tipos de termopar, incluindo J, K, T, E, R, S, B, N, C e L.\u003c\/p\u003e\n\u003cp\u003eP: Como o isolamento dos canais afeta a precisão do termopar?\u003cbr\u003eR: O isolamento entre canais elimina o acoplamento elétrico entre as junções dos sensores, reduzindo o erro de medição causado por potenciais de terra compartilhados ou interferência no circuito.\u003c\/p\u003e\n\u003cp\u003eP: Qual é o efeito da seleção do modo de varrimento na velocidade de atualização?\u003cbr\u003eR: O modo inteiro proporciona desempenho de varrimento mais rápido (até 10 ms), enquanto a conversão de temperatura em ponto flutuante IEEE aumenta o tempo de varrimento até 50 ms devido ao cálculo adicional de escala.\u003c\/p\u003e\n\u003chr\u003e\u003chr\u003e\n\u003ch3\u003eDiretrizes para Instalação em Campo\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eInstale o módulo numa ranhura compatível do chassis 1756 ControlLogix com a alimentação do sistema desligada ou seguindo o procedimento aprovado de hot-swap\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUtilize os blocos de terminais RTB especificados (1756-TBNH ou 1756-TBSH) com encaixe completo antes de energizar os circuitos de campo\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMantenha a integridade da fiação do termopar usando cabo de compensação blindado compatível com o tipo de sensor\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEvite passar os cabos do termopar perto de condutores de alta tensão ou linhas de alimentação comutadas\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAssegure a colocação correta da compensação da junta fria e a ausência de gradientes de temperatura induzidos por fluxo de ar no bloco de terminais\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVerifique a configuração do tipo de termopar antes da ativação do circuito para evitar erros de escala\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Allen-Bradley","offers":[{"title":"Default Title","offer_id":43602855624794,"sku":"1756-IT61","price":123.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/1756-IT612.jpg?v=1783320124","url":"https:\/\/www.plcmasters.com\/pt\/products\/allen-bradley-1756-it6i-controllogix-thermocouple-input-module","provider":"PLC Masters Ltd.","version":"1.0","type":"link"}