{"product_id":"honeywell-51304685-150-advanced-communications-card","title":"Honeywell 51304685-150 Advanced Communications Card","description":"\u003ch3\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe Honeywell\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e51304685-150\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eAdvanced Communications Card (ACC) is a dedicated system communication module engineered for Honeywell TDC3000 and TPS distributed control platforms. It functions as a core network interface, enabling reliable data exchange between Advanced Process Manager (APM) controllers and the Universal Control Network (UCN).\u003c\/p\u003e\n\u003cp\u003eDesigned for continuous-duty industrial environments, the ACC supports deterministic communication behavior, precise time synchronization, and long-term operational stability. Its conformally coated circuitry and fault-tolerant design make it suitable for critical process control installations where uptime and data integrity are essential.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCore Functional Capabilities\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e51304685-150\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eACC acts as a system-level communications bridge rather than a fieldbus interface. It manages internal control-network traffic, ensures consistent data timing, and supports synchronized event handling across distributed nodes.\u003c\/p\u003e\n\u003cp\u003eKey functional characteristics include real-time cyclic data transfer, high-accuracy timestamping for alarms and events, and integrated diagnostics for monitoring network and module health. The card is designed to operate continuously within Honeywell-approved chassis and backplanes without external power wiring.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch3\u003e\u003cstrong\u003eSystem Compatibility\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eCompatible Control Systems\u003cbr\u003eHoneywell TDC3000\u003cbr\u003eHoneywell TPS\u003cbr\u003eAdvanced Process Manager (APM)\u003c\/p\u003e\n\u003cp\u003eNetwork Architecture\u003cbr\u003eUniversal Control Network (UCN)\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCommunication Characteristics\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eCommunication Function\u003cbr\u003eSystem-level network interface module\u003c\/p\u003e\n\u003cp\u003eSupported Network\u003cbr\u003eHoneywell proprietary UCN\u003c\/p\u003e\n\u003cp\u003eData Handling\u003cbr\u003eDeterministic, cyclic system communication\u003c\/p\u003e\n\u003cp\u003eTime Synchronization\u003cbr\u003eHigh-precision time stamping for events and alarms\u003c\/p\u003e\n\u003cp\u003eDiagnostics\u003cbr\u003eOn-board status monitoring\u003cbr\u003eCommunication fault detection\u003cbr\u003eNetwork integrity reporting\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eElectrical Characteristics\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003ePower Source\u003cbr\u003eSupplied directly from Honeywell system backplane\u003c\/p\u003e\n\u003cp\u003eTypical Power Consumption\u003cbr\u003e5–10 W depending on configuration\u003c\/p\u003e\n\u003cp\u003eElectrical Isolation\u003cbr\u003eGalvanic isolation between network circuitry and system bus to reduce noise and fault propagation\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eEnvironmental Ratings\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eOperating Temperature\u003cbr\u003e0°C to 60°C\u003c\/p\u003e\n\u003cp\u003eStorage Temperature\u003cbr\u003e–40°C to 85°C\u003c\/p\u003e\n\u003cp\u003eRelative Humidity\u003cbr\u003e5% to 95%, non-condensing\u003c\/p\u003e\n\u003cp\u003eMechanical Robustness\u003cbr\u003eMeets Honeywell industrial vibration and shock requirements\u003c\/p\u003e\n\u003cp\u003eCoating\u003cbr\u003eConformal coating for resistance to moisture, dust, and corrosive atmospheres\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eMechanical and Physical Details\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eForm Factor\u003cbr\u003eStandard Honeywell TDC3000\/TPS plug-in module\u003c\/p\u003e\n\u003cp\u003eMounting\u003cbr\u003eCompatible with Honeywell system chassis and backplanes\u003c\/p\u003e\n\u003cp\u003eStatus Indicators\u003cbr\u003eLED indicators for power presence\u003cbr\u003eModule operational status\u003cbr\u003eNetwork communication activity\u003c\/p\u003e\n\u003cp\u003eWeight\u003cbr\u003e2.0 lbs\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTypical Application Scenarios\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eSystem communication interface for APM controllers\u003cbr\u003eNetwork connectivity within TDC3000 and TPS systems\u003cbr\u003eEvent and alarm synchronization across UCN nodes\u003cbr\u003eModernization and lifecycle support of legacy Honeywell DCS installations\u003cbr\u003eProcess automation systems in refining, petrochemical, power generation, and heavy manufacturing facilities\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ch3\u003e\u003cstrong\u003eWhat is the primary role of the 51304685-150 ACC?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe card provides internal system communication between APM controllers and the Universal Control Network, ensuring deterministic data exchange and synchronized system operation.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eIs this module a fieldbus or I\/O interface?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eNo. The ACC is a system communication module and does not interface directly with field devices or I\/O signals.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eCan the ACC be replaced without system shutdown?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eHot-swap capability depends on the specific chassis and system configuration. Always follow Honeywell maintenance procedures before replacement.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eIs this module suitable for harsh industrial environments?\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eYes. The conformally coated design and industrial environmental ratings support long-term operation in demanding control room and plant environments.\u003c\/p\u003e","brand":"HONEYWELL","offers":[{"title":"Default Title","offer_id":42912554909786,"sku":"51304685-150","price":209.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/51304685-1502.jpg?v=1770778708","url":"https:\/\/www.plcmasters.com\/pt\/products\/honeywell-51304685-150-advanced-communications-card","provider":"PLC Masters Ltd.","version":"1.0","type":"link"}