{"product_id":"honeywell-mu-tamr02-51301376-low-level-analog-input-module","title":"Honeywell MU-TAMR02 51301376 Low-Level Analog Input Module","description":"\u003ch3\u003e\u003cstrong\u003eProduct Overview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe Honeywell\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMU-TAMR02 (51301376)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a precision low-signal analog input module engineered for Honeywell distributed control systems. It is specifically developed to process very small electrical signals with high stability and repeatability, making it suitable for temperature sensing and other low-energy measurement tasks.\u003c\/p\u003e\n\u003cp\u003eThis module conditions, multiplexes, and digitizes weak field signals such as RTDs or low-amplitude voltages, delivering reliable data to the control processor in demanding industrial environments. Its design prioritizes signal integrity, long-term accuracy, and compatibility with Honeywell legacy and transitional DCS architectures.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFunctional Characteristics\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMU-TAMR02 (51301376)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eoperates as a low-level signal acquisition interface within Honeywell control systems. It combines signal multiplexing and analog-to-digital conversion in a compact hardware format, reducing system complexity while maintaining measurement fidelity.\u003c\/p\u003e\n\u003cp\u003eKey functional attributes include stable handling of low-energy sensor outputs, consistent performance under continuous operation, and robust electrical isolation appropriate for process environments where noise immunity is critical.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eInput and Measurement Performance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSupported Signal Types: Low-level voltage inputs and RTD temperature sensors\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConfigurable Input Ranges:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eLow-voltage analog signals (typical millivolt-level ranges depending on system configuration)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRTD resistance measurement via controller-defined scaling\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003eNumber of Channels: 2 multiplexed inputs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConversion Resolution: 12-bit analog-to-digital conversion\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMeasurement Accuracy: ±0.5% of full scale (typical)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSampling Frequency: Up to 100 samples per second\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical Requirements\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eOperating Supply Voltage: 24 VDC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCurrent Consumption: Approximately 110 mA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDesigned for continuous duty in control cabinets and system enclosures\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical and Environmental Data\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eDimensions: Approx. 96 × 96 × 76 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWeight: 0.5 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMounting: System rack or chassis installation per Honeywell DCS standards\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTypical Applications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eMU-TAMR02 (51301376)\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis commonly deployed in applications requiring precise measurement of weak analog signals, including:\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eRTD-based temperature monitoring in process units\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eLow-voltage sensor acquisition in chemical and energy facilities\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSignal conditioning for legacy Honeywell TDC and TPS system expansions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eControl loops where signal stability and repeatability are critical\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFrequently Asked Questions\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Is this module suitable for thermocouple inputs?\u003c\/strong\u003e\u003cbr\u003eA: No. The MU-TAMR02 is intended for low-level voltage and RTD signals. Thermocouples typically require dedicated cold-junction compensation modules.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Can this module be used in modern Experion systems?\u003c\/strong\u003e\u003cbr\u003eA: It is primarily designed for Honeywell legacy and transitional DCS platforms. Compatibility depends on the specific system architecture and I\/O rack configuration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the module perform signal scaling internally?\u003c\/strong\u003e\u003cbr\u003eA: Signal conditioning and digitization are handled at the module level, while engineering scaling is typically configured in the controller or system software.\u003c\/p\u003e","brand":"HONEYWELL","offers":[{"title":"Default Title","offer_id":42912730579034,"sku":"MU-TAMR02 51301376","price":209.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/MU-TAMR02513013762.jpg?v=1770793182","url":"https:\/\/www.plcmasters.com\/pt\/products\/honeywell-mu-tamr02-51301376-low-level-analog-input-module","provider":"PLC Masters Ltd.","version":"1.0","type":"link"}