{"product_id":"bently-nevada-87900-02-system-front-panel","title":"Bently Nevada 87900-02 System Front Panel","description":"\u003ch3\u003eProduct Description\u003c\/h3\u003e\n\u003cp\u003eThe Bently Nevada 87900-02 System Front Panel provides an intuitive interface for Keyphasor modules in industrial machinery protection systems. It enables real-time monitoring of dual-channel Keyphasor signals while displaying module status, alarms, and operational health. Moreover, the front panel integrates seamlessly with Bently Nevada 3300 and 3500 series racks, supporting predictive maintenance initiatives in critical rotating equipment. Its robust design ensures electrical isolation and safe operation, allowing engineers to confidently monitor phase reference signals across turbines, compressors, and pumps.\u003c\/p\u003e\n\u003cp\u003eIn addition, the LED indicators and channel labels provide immediate visual feedback, reducing diagnostic time during maintenance. The front panel outputs TTL-level digital pulses proportional to shaft rotation, enabling precise phase reference measurements for vibration analysis and shaft position monitoring. Its dual-channel support allows redundancy or multiple shaft reference inputs, enhancing system reliability. For instance, operators can quickly detect signal loss, alarm conditions, or abnormal module behavior, ensuring continuous machinery protection.\u003c\/p\u003e\n\u003ch3\u003eKey Functional Highlights\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePhase Reference Monitoring:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTracks Keyphasor signal integrity for vibration diagnostics and predictive maintenance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDual-Channel Support:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eMonitors two independent probes simultaneously for redundancy or multi-shaft applications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVisual Alarm Indicators:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eProvides immediate alerts for abnormal conditions or signal interruptions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eLED Status Indicators:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDisplays module health, channel status, and operational performance at a glance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSeamless Rack Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFits standard Bently Nevada 3300\/3500 monitoring racks with easy front-panel accessibility.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical Isolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eEnsures safe channel-to-channel operation and reliable system performance.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBently Nevada 87900-02\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModule Type: \u003c\/strong\u003eSystem Front Panel\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSystem Compatibility:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eBently Nevada 3300\/3500 series racks\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eInput Channels:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eDual-channel (Channel A \u0026amp; B)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOutput:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eTTL-level digital pulses proportional to shaft rotation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIndicators:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eLED status lights for module health, alarms, and channel activity\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAlarm Functions:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eVisual alerts for signal loss and abnormal operation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eRack Integration:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eFront-panel mountable with standard 3300\/3500 series racks\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIsolation:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eChannel-to-channel electrical isolation for safety\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Environment:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eIndustrial machinery conditions (turbines, compressors, pumps)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTypical Applications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eTurbine vibration monitoring and phase reference measurement\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompressor shaft position diagnostics and predictive maintenance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePump machinery protection and dual-channel signal monitoring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIntegration with Bently Nevada 3300\/3500 racks for industrial automation systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eFAQ\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ1: Is the 87900-02 compatible with older Bently Nevada racks?\u003c\/strong\u003e\u003cbr\u003eA1: The module is designed for 3300 and 3500 series racks, but backward compatibility depends on your system configuration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ2: Can this front panel handle dual-shaft monitoring?\u003c\/strong\u003e\u003cbr\u003eA2: Yes, it supports dual-channel inputs for redundancy or multiple shaft references.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ3: What type of signal output does it provide?\u003c\/strong\u003e\u003cbr\u003eA3: It delivers TTL-level digital pulses proportional to shaft rotation, suitable for phase reference measurements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ4: How does it alert operators of abnormal conditions?\u003c\/strong\u003e\u003cbr\u003eA4: LED indicators and alarm signals provide immediate visual feedback for system health and signal loss.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ5: Is electrical isolation provided between channels?\u003c\/strong\u003e\u003cbr\u003eA5: Yes, the panel ensures channel-to-channel isolation for safe operation in industrial environments.\u003c\/p\u003e","brand":"Bently Nevada","offers":[{"title":"Default Title","offer_id":42713850445914,"sku":"87900-02","price":226.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/330020-12-01-02-00-022.jpg?v=1767063927","url":"https:\/\/www.plcmasters.com\/ru\/products\/bently-nevada-87900-02-system-front-panel","provider":"PLC Masters Ltd.","version":"1.0","type":"link"}