The KC4011X1-BQ1 from Emerson is a 40-pin simplex discrete output (DO) mass terminal block designed for DeltaV systems. It provides a secure and organized interface for connecting multiple DO cards to field devices, ensuring reliable signal distribution in hazardous areas.
Engineered for Zone 2 / Class I Division 2 installations, this terminal block features LS1 keyed connections to prevent wiring errors. Its robust construction ensures operation under extreme temperatures, humidity, vibration, and shock conditions. The compact form factor simplifies installation while maintaining high reliability for process automation applications.
Technical Specifications
-
Model: KC4011X1-BQ1
-
Module Type: Simplex Discrete Output Mass Terminal Block
-
Channels: 40-pin connections for discrete outputs
-
Compatibility: Designed for Emerson DeltaV DO cards (S-series and SIS systems)
-
Nominal Voltage: 24 VDC
-
Field Circuit Power: 24 VDC at 100 mA per channel
-
Dimensions: 110 × 45 × 120 mm
-
Weight: 0.4 kg
-
Operating Temperature: –40 °C to +70 °C
-
Humidity: 5–95% RH, non-condensing
-
Shock Resistance: 10 g, half-sine wave, 11 ms
-
Vibration: 2–13.2 Hz: 1 mm peak-to-peak; 13.2–150 Hz: 0.7 g
-
Airborne Contaminants: ISA-S71.04-1985 Class G3
-
Terminal Block Key Position: B4
Safety & Compliance
-
Hazardous Atmosphere Ratings:
-
II 3G Ex ec IIC Gc
-
Class I, Division 2, Groups A–D
-
Zone 2 AEx/Ex ec IIC Gc
-
Certifications: ATEX, IECEx, FM, UKEX approvals for hazardous locations
-
Installation Note: Follow proper procedures for installation, removal, and operation in hazardous areas
Key Highlights
-
Provides mass termination for up to 40 discrete outputs, reducing wiring complexity
-
Certified for hazardous environments (Zone 2 / Class I Div. 2)
-
Rugged design withstands temperature extremes, vibration, and shock
-
Compact and lightweight for easy integration into DeltaV racks
-
Ensures consistent and reliable signal distribution for control and automation
Applications
-
Termination of multiple discrete output signals in DeltaV systems
-
Hazardous area installations for process control in oil, gas, and chemical plants
-
Field wiring organization and protection for DO cards
FAQ
Q: Can KC4011X1-BQ1 be used with SIS DeltaV cards?
A: Yes, it is compatible with both standard S-series and SIS DO cards.
Q: What is the maximum current per channel?
A: Each channel supports up to 100 mA at 24 VDC.
Q: Is this terminal block suitable for Zone 2 hazardous areas?
A: Yes, it meets ATEX, IECEx, FM, and UKEX standards for Zone 2 / Class I Div. 2 environments.
Особенности
Мы приветствуем оптовые заказы и минимальное количество заказа всего одна единица.
По запросу мы можем предоставить всю необходимую документацию, включая сертификаты происхождения/соответствия и другие требуемые экспортные документы.
Для товаров в наличии мы стремимся доставить в течение 1-3 дней после подтверждения оплаты. Товары с указанными сроками поставки будут доставлены согласно заявленному графику.
Мы принимаем 100% оплату T/T (телеграфным переводом) до отправки. Для товаров с длительным сроком изготовления требуется предоплата в размере 30%, оставшиеся 70% оплачиваются перед отправкой. Для переводов в юанях (RMB) свяжитесь с нами, если у вас есть агент в Китае.
Мы предлагаем стандартную годовую гарантию на все новые и оригинальные товары. Если вам нужна расширенная гарантия, пожалуйста, свяжитесь с нами для получения информации о дополнительной стоимости.
Ваше удовлетворение важно для нас. Если вам нужно вернуть товар, это должно быть сделано в течение 30 дней с даты заказа. Продукт должен быть неиспользованным, нераспечатанным и в оригинальной упаковке со всеми включёнными аксессуарами. Возврат средств осуществляется в течение 5-7 рабочих дней после получения возвращённого товара. Обратите внимание, что стоимость доставки и сопутствующие расходы не подлежат возврату.