{"product_id":"foxboro-p0973cnd-fcp-termination-module-i-a-series","title":"Foxboro P0973CND FCP Termination Module I\/A Series","description":"\u003ch3\u003e\u003cstrong\u003eProduct Description\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eFoxboro P0973CND\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis a field termination assembly engineered to interface field wiring directly with Foxboro Field Control Processors (FCPs) within the I\/A Series Distributed Control System. It provides a structured and reliable connection point for routing both analog and discrete signals from field instruments into the control layer.\u003c\/p\u003e\n\u003cp\u003eAs a passive termination unit, it does not require independent power for signal handling, which simplifies installation and improves overall system reliability. The module is designed for continuous operation in demanding industrial environments, with robust mechanical construction to withstand vibration, temperature variation, and long-term use.\u003c\/p\u003e\n\u003cp\u003eIn some system configurations, the\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eP0973CND\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis supplied as part of an integrated FCP assembly, which explains references to onboard processing and memory. However, in its standalone role, it functions strictly as a signal termination and distribution interface.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eGeneral Information\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eModel:\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eP0973CND\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFunctional Type: Field Termination Assembly\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSystem Compatibility: Foxboro I\/A Series FCP platforms\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRole: Signal termination and routing interface for field devices\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eElectrical Characteristics\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSignal Types Supported: Analog and digital I\/O\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTerminal Count: Typically 32 points\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTerminal Style: Screw-clamp connections\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupported Wire Size: 14–22 AWG\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower Requirement: Not required for passive operation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eIntegrated System Variant (when part of FCP assembly)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eProcessor: Single CPU (dual optional for redundancy)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMemory: Approx. 16 MB SDRAM, 32 MB Flash\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupply Voltage: 24 VDC (redundant input supported)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower Consumption: Up to 8.5 W (applies to active assemblies only)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eMechanical Details\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eMounting Options: DIN rail or panel-mounted installation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHousing Material: Industrial-grade thermoplastic (polycarbonate typical)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDimensions: Vary by revision, approx.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e100 × 50 × 25 mm (compact form)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUp to 6 × 18 × 20 cm (assembly variant)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003eWeight: 0.5 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmental Ratings\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eOperating Temperature:\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003ePassive module: –40 °C to +85 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProcessor-integrated assembly: 0 °C to +60 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cli\u003e\n\u003cp\u003eStorage Temperature: –55 °C to +90 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHumidity: Up to 95% RH, non-condensing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eResistance: Designed for vibration, dust exposure, and industrial conditions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eCentralized termination point for structured field wiring\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePassive architecture reduces failure points and simplifies maintenance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupports mixed analog and discrete signal termination\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFlexible mounting options for cabinet integration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRugged enclosure suitable for harsh process environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSeamless compatibility with Foxboro FCP-based systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eApplication Scenarios\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eField signal termination in Foxboro DCS cabinets\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInterface layer between sensors\/actuators and FCP controllers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProcess industries including oil \u0026amp; gas, power generation, and chemicals\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHigh-vibration installations such as turbines and heavy machinery systems\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Does the P0973CND require a power supply?\u003c\/strong\u003e\u003cbr\u003eA: No. In its standard form, it is a passive termination module and does not consume power.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: Why do some listings mention CPU and memory?\u003c\/strong\u003e\u003cbr\u003eA: Those specifications refer to configurations where the module is integrated into an FCP assembly. The standalone termination unit itself does not include active processing.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQ: What type of wiring does it support?\u003c\/strong\u003e\u003cbr\u003eA: It uses screw terminals compatible with 14–22 AWG wires, suitable for typical industrial field wiring practices.\u003c\/p\u003e","brand":"Foxboro","offers":[{"title":"Default Title","offer_id":43198968299610,"sku":"P0973CND","price":177.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/P0917TQ2_c785553b-2e3e-48c7-86bd-1bbb92214b44.jpg?v=1775630917","url":"https:\/\/www.plcmasters.com\/ru\/products\/foxboro-p0973cnd-fcp-termination-module-i-a-series","provider":"PLC Masters Ltd.","version":"1.0","type":"link"}