Açıklama
Overview
The EPRO CON021/915-080 is a high-precision eddy current signal converter designed for rotating machinery monitoring. It accurately measures shaft displacement, position, eccentricity, and speed/key signals. It is widely used in steam, gas, and hydro turbines, as well as compressors, pumps, and fans.
This model works with multiple eddy current probes, including PR6422, PR6423, PR6424, PR6425 (requires extended range converter), PR6426, and PR6453. It converts sensor signals into standardized analog outputs for integration with monitoring and protection systems. The CON021/915-080 is optimized for MMS 6000 and IMR 6000 rack systems and supports hot-swappable installation, ensuring continuous operation of critical rotating equipment.
Technical Specifications
| Parameter | Specification |
|---|---|
| Function | Eddy current signal converter for shaft displacement, position, eccentricity, and speed/key monitoring |
| Frequency Range | 0–20 kHz (-3 dB) |
| Rise Time | <15 μs for accurate dynamic measurement |
| Compatible Sensors | PR6422, PR6423, PR6424, PR6425 (extended range), PR6426, PR6453 |
| Supply Voltage | -23V to -32V (Output -4V to -20V) -21V to -32V (Output -2V to -18V) |
| Output Signal | Standardized analog output (depending on configuration) |
| Operating Temperature | -30°C to +100°C (-22°F to +212°F) |
| Shock & Vibration | 5g @ 60 Hz @ 25°C |
| Protection Class | IP20 |
| Housing Material | LMgSi 0.5 F22 Aluminum Alloy |
| Weight | 120 g |
| Mounting | Rack-based installation (MMS 6000 / IMR 6000 compatible) |
| Connections | Self-locking LEMO plug or screw terminal options |
| Integration | Hot-swappable for rack systems |
Applications
-
Steam, gas, and hydro turbine monitoring
-
Rotating machinery: compressors, pumps, and fans
-
Process control and protection systems
FAQ
Q1: Which sensors are compatible with CON021/915-080?
A1: Compatible with PR6422, PR6423, PR6424, PR6425 (extended range), PR6426, and PR6453.
Q2: Can this module be replaced while running?
A2: Yes, it supports hot-swappable installation in MMS 6000 and IMR 6000 racks.
Q3: What is the typical measurement range?
A3: Using PR6425 extended range, ±8.0 mm with ≤3% linearity error.
Q4: What is the operating temperature range?
A4: -30°C to +100°C, suitable for most industrial rotating machinery environments.
Özellikler
Toplu siparişleri memnuniyetle karşılıyoruz ve minimum sipariş miktarımız sadece bir birimdir.
Talep üzerine, Menşe/ Uygunluk Sertifikaları ve diğer gerekli ihracat belgeleri dahil olmak üzere tüm gerekli belgeleri sağlayabiliriz.
Stokta bulunan ürünler için, ödeme onayından sonra 1-3 gün içinde teslim etmeyi hedefliyoruz. Belirtilen teslim sürelerine sahip ürünler, belirtilen programa göre teslim edilecektir.
Gönderimden önce %100 T/T (Telgraf Transferi) ödemesini kabul ediyoruz. Teslim süresi olan ürünler için %30 depozito önceden alınır, kalan %70 ise gönderimden önce ödenir. RMB transferleri için, Çin'de bir temsilciniz varsa lütfen bizimle iletişime geçin.
Tüm yeni ve orijinal ürünlerde standart bir yıllık garanti sunuyoruz. Uzatılmış garanti talep ediyorsanız, lütfen ek maliyet detayları için bizimle iletişime geçin.
Memnuniyetiniz bizim için önemlidir. Bir ürünü iade etmeniz gerekiyorsa, bu sipariş tarihinden itibaren 30 gün içinde yapılmalıdır. Ürün kullanılmamış, açılmamış ve tüm aksesuarlarıyla birlikte orijinal ambalajında olmalıdır. İadeler, iade edilen ürünü aldıktan sonra 5-7 iş günü içinde işlenir. Lütfen nakliye ve ilgili ücretlerin iade edilmediğini unutmayın.