{"product_id":"ge-fanuc-ic670alg620-4-channel-rtd-input-module-field-control","title":"GE Fanuc IC670ALG620 4-Channel RTD Input Module Field Control","description":"\u003ch3\u003e\u003cstrong\u003eOverview\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIC670ALG620\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emodule from GE Fanuc is a high-precision RTD input interface designed for Field Control systems. It supports four independent channels and is compatible with both 3-wire and 4-wire RTD sensors, including Platinum, Nickel, Nickel\/Iron, and Copper types. The module converts resistance measurements into accurate temperature data for process monitoring, control applications, and industrial automation systems.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Features\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eFour fully isolated RTD input channels for flexible sensor integration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupports 3-wire and 4-wire RTD configurations\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConfigurable measurement ranges: 0–500 Ω or 0–3000 Ω\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOutputs in resistance (Ω), Celsius (°C), or Fahrenheit (°F) with tenths resolution\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBuilt-in diagnostics for open-wire, short-circuit, overrange\/underrange, and high\/low alarms\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNo external loop power required, reducing installation complexity\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIndustrial-grade reliability for continuous operation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003e\u003cstrong\u003eTechnical Specifications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003ctable class=\"w-fit min-w-(--thread-content-width)\"\u003e\n\u003cthead\u003e\n\u003ctr class=\"firstRow\"\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel Number\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003eIC670ALG620\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e4 independent RTD inputs (3-wire or 4-wire)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported RTD Types\u003c\/td\u003e\n\u003ctd\u003ePlatinum, Nickel, Nickel\/Iron, Copper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistance Ranges\u003c\/td\u003e\n\u003ctd\u003e0–500 Ω, 0–3000 Ω (selectable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Units\u003c\/td\u003e\n\u003ctd\u003eΩ, °C, °F (tenths resolution)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScan Time\u003c\/td\u003e\n\u003ctd\u003e210 ms (60 Hz), 230 ms (50 Hz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Resolution\u003c\/td\u003e\n\u003ctd\u003e15-bit plus sign\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Lead Resistance\u003c\/td\u003e\n\u003ctd\u003e5 Ω per lead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNormal Mode Rejection\u003c\/td\u003e\n\u003ctd\u003e60 dB at 50\/60 Hz, 100% span\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Sensitivity\u003c\/td\u003e\n\u003ctd\u003e±0.004% of reading, ±1.5 mV\/°C referred to input (0–60°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFault Detection\u003c\/td\u003e\n\u003ctd\u003eOpen RTD, short, underrange, overrange, high\/low alarms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Requirements\u003c\/td\u003e\n\u003ctd\u003eDraws up to 190 mA from BIU supply, no loop power needed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e120 × 50 × 100 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e0.45 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003cstrong\u003eApplications\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eIdeal for process control systems, distributed control stations, and temperature monitoring in industrial environments where precise RTD measurements are required. It integrates seamlessly with GE Field Control systems for automated and reliable operation.\u003c\/p\u003e\n\u003ch3\u003e\u003cstrong\u003eFAQ\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cp\u003eQ: Can the module measure multiple RTD types simultaneously?\u003cbr\u003eA: Yes, each channel can be individually configured for Platinum, Nickel, Nickel\/Iron, or Copper RTDs.\u003c\/p\u003e\n\u003cp\u003eQ: Is external power required for the RTDs?\u003cbr\u003eA: No, the module does not require loop power; it draws power directly from the Bus Interface Unit.\u003c\/p\u003e\n\u003cp\u003eQ: How is configuration performed?\u003cbr\u003eA: The module is configured via a handheld device connected to the main Bus Interface Unit.\u003c\/p\u003e","brand":"GE Fanuc","offers":[{"title":"Default Title","offer_id":42774561390682,"sku":"IC670ALG620","price":175.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/IC670ALG6202.jpg?v=1768457776","url":"https:\/\/www.plcmasters.com\/uk\/products\/ge-fanuc-ic670alg620-4-channel-rtd-input-module-field-control","provider":"PLC Masters Ltd.","version":"1.0","type":"link"}