{"product_id":"schneider-bmenua0100-opc-ua-communication-module","title":"Schneider BMENUA0100 OPC UA Communication Module","description":"\u003ch3\u003eOverview\u003c\/h3\u003e\n\u003cp\u003eThe\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSchneider Electric BMENUA0100\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eis an\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003eOPC UA Communication Module\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003ewith an embedded OPC UA server, designed for\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eModicon M580 ePAC controllers\u003c\/strong\u003e. It enables secure and standardized industrial data exchange between controllers and external systems, ensuring seamless interoperability across connected networks. This module delivers high-performance OPC UA capabilities, supporting up to 10 clients simultaneously with reliable, encrypted communication. It integrates easily into Modicon X80 Ethernet backplanes, providing Ethernet transparency and robust cybersecurity features such as certificate-based authentication and a built-in firewall.\u003c\/p\u003e\n\u003ch3\u003eTechnical Specifications\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eModel\u003c\/strong\u003e: BMENUA0100\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eProduct Type\u003c\/strong\u003e: OPC UA Communication Module\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePlatform\u003c\/strong\u003e: Modicon M580 ePAC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFunction\u003c\/strong\u003e: Acts as a secure data interface for OPC UA communication\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCompatibility\u003c\/strong\u003e: Works with M580 standalone, redundant, and safety CPUs\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMounting Location\u003c\/strong\u003e: Main rack, Ethernet or X-bus slot\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMaximum Modules per Rack\u003c\/strong\u003e: 2\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIntegrated Port\u003c\/strong\u003e: 1 RJ45 Ethernet port (10\/100\/1000 Mbit\/s, shielded twisted pair)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e: Internal via rack, ≤140 mA at 24 V DC\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOPC UA Features\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eEmbedded\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eOPC UA Server\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ecompliant with V1.03 standard\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e10 client connections\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHandles up to\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003e50,000 monitored items\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(standard mode)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFast sampling\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003emode supports 2,000 monitored items\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eMinimum publishing interval\u003c\/strong\u003e: 20 ms (fast mode)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003esource timestamping\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003ewarm redundancy\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSCADA connection\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ethrough communication protocol forwarding\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eNetwork and Communication\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eSupports\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIPv6\u003c\/strong\u003e,\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eIP forwarding\u003c\/strong\u003e, and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003enetwork segmentation\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProvides\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eModbus TCP server\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor module diagnostics\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIncludes\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eSNMP agent\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(V1\/V3) and\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eNTP V4\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor time synchronization\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eWeb server\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor commissioning, operation, and maintenance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHot-swappable\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003ewith CCOTF (Configuration Change on the Fly) capability\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eCybersecurity\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHTTPS\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003esecure communication\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBuilt-in\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003efirewall\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003erole-based access control\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCertificate management\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e(self-signed or PKI)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSyslog\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eprotocol support\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIPSec\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003efor VPN compatibility\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSystem hardening\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand physical network isolation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eIndicators and Diagnostics\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003eLED indicators for RUN, ERR, ETH MS, ETH NS, STS, and communication status\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAdvanced diagnostic data via\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eweb pages\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003eand\u003cspan\u003e \u003c\/span\u003e\u003cstrong\u003eOPC UA objects\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePhysical and Environmental Data\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e: 32 mm (W) × 131 mm (H) × 86 mm (D)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNet Weight\u003c\/strong\u003e: 0.4 kg\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eIP Rating\u003c\/strong\u003e: IP20\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eOperating Temperature\u003c\/strong\u003e: 0 to 60 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eStorage Temperature\u003c\/strong\u003e: -40 to 85 °C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHumidity\u003c\/strong\u003e: 5 to 95% (non-condensing)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eVibration Resistance\u003c\/strong\u003e: 3 gn\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eShock Resistance\u003c\/strong\u003e: 30 gn\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAltitude\u003c\/strong\u003e: Up to 5000 m with derating\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eEnvironmental Sustainability\u003c\/h3\u003e\n\u003cul class=\"list-paddingleft-2\"\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eCarbon Footprint\u003c\/strong\u003e: 186 kg CO₂ eq (total life cycle)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003ePackaging\u003c\/strong\u003e: Made from recycled cardboard\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eTake-Back Program\u003c\/strong\u003e: Not applicable\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Schneider","offers":[{"title":"Default Title","offer_id":42417170808922,"sku":"BMENUA0100","price":182.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0612\/4601\/3530\/files\/BMENUA01002.jpg?v=1760169130","url":"https:\/\/www.plcmasters.com\/vi\/products\/schneider-bmenua0100-opc-ua-communication-module","provider":"PLC Masters Ltd.","version":"1.0","type":"link"}