Zum Inhalt springen
Honeywell FS-TSDO-04UNI Safe Digital Output Module

Honeywell FS-TSDO-04UNI Safe Digital Output Module

  • 1000 Auf Lager
  • Manufacturer: HONEYWELL

  • Product No.: FS-TSDO-04UNI

  • Condition: Auf Lager

  • Product Type: Safe Digital Output Module

  • Product Origin: USA

  • Payment:T/T, Western Union

  • Weight: 400g

  • Shipping port: Xiamen

  • Warranty: 12 months

{"id":42912751943770,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"FS-TSDO-04UNI","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Honeywell FS-TSDO-04UNI Safe Digital Output Module","public_title":null,"options":["Default Title"],"price":20900,"weight":400,"compare_at_price":45000,"inventory_management":"shopify","barcode":"USA","requires_selling_plan":false,"selling_plan_allocations":[]}

Beschreibung

Product Overview

The FS-TSDO-04UNI is a safety-rated digital output module developed for Honeywell fault-tolerant safety platforms. It delivers four independent output channels engineered to drive both AC and DC field loads under strict functional-safety constraints. Designed for continuous operation in high-risk industrial facilities, this module forms a reliable interface between the safety controller and final control elements such as solenoids, relays, and shutdown devices.

Integrated seamlessly into Honeywell FSC architectures, the module supports safety instrumented functions (SIFs) that demand deterministic behavior, electrical isolation, and predictable failure modes.

Key Functional Characteristics

The FS-TSDO-04UNI provides four galvanically isolated output channels, each designed with fail-safe behavior to ensure outputs transition to a defined safe state during power loss, internal fault detection, or system shutdown.

The outputs are designed to accommodate universal load types, allowing the same channel design to switch low-voltage DC devices as well as higher-voltage AC actuators. This flexibility reduces I/O diversity while maintaining compliance with international safety standards.

Electrical and Output Specifications

  • Four independent safety-rated digital output channels

  • Galvanic isolation between channels and system backplane

  • Universal load capability supporting both AC and DC field devices

  • Maximum switching voltage up to 50 V DC (Overvoltage Category III)

  • Maximum switching voltage up to 150 V DC (Overvoltage Category II)

  • Designed for deterministic response in safety logic execution

  • Output state monitoring for safety diagnostics and fault reporting

Safety, Compliance, and Certification

The FS-TSDO-04UNI is certified for use in safety-critical applications and complies with major global regulatory frameworks, making it suitable for deployment in regulated process industries.

  • CE conformity for European installations

  • TÜV certification for functional safety compliance

  • UL and CSA approval for North American markets

  • FM certification for use in hazardous and high-reliability environments

These certifications support use in SIL-rated safety instrumented systems when applied according to Honeywell safety manuals.

Mechanical and Installation Details

  • Compact module design optimized for 19-inch rack-mounted safety systems

  • Standard module dimensions approximately 60 × 70 × 54 mm

  • Optional field termination assembly (FTA) variant available

  • Dimensions: 45 × 120 × 130 mm

  • Weight 0.4 kg

  • Manufactured in the United States

The compact footprint allows high I/O density while maintaining adequate spacing for heat dissipation and wiring access.

Typical Application Areas

The FS-TSDO-04UNI is commonly deployed in environments where output reliability directly affects personnel safety and asset protection, including:

  • Emergency shutdown systems in oil and gas facilities

  • Burner management and combustion safety systems

  • Chemical reactor isolation and venting control

  • Power generation protection and turbine shutdown logic

Frequently Asked Questions

Q: Can the FS-TSDO-04UNI drive both AC and DC loads on the same module?
A: Yes. Each output channel is designed to support universal AC or DC loads within the specified voltage limits.

Q: What happens to the outputs during a system fault or power loss?
A: The module is fail-safe by design. Outputs transition to a predefined safe state as required by the safety logic configuration.

Q: Is this module compatible with standard Honeywell FSC controllers?
A: Yes. The FS-TSDO-04UNI is specifically designed for integration into Honeywell FSC fault-tolerant safety systems.

Zeig mehr

Wir begrüßen Großbestellungen und haben eine Mindestbestellmenge von nur einer Einheit.

Auf Anfrage können wir alle notwendigen Dokumente bereitstellen, einschließlich Ursprungs-/Konformitätszertifikate und andere erforderliche Exportdokumente.

Für vorrätige Artikel streben wir eine Lieferung innerhalb von 1-3 Tagen nach Zahlungseingang an. Artikel mit angegebenen Lieferzeiten werden gemäß dem angegebenen Zeitplan geliefert.

Wir akzeptieren 100% T/T (Telegraphische Überweisung) Zahlung vor dem Versand. Für Artikel mit Lieferzeiten ist eine Anzahlung von 30% im Voraus erforderlich, der verbleibende Rest von 70% ist vor dem Versand fällig. Für RMB-Überweisungen kontaktieren Sie uns bitte, wenn Sie einen Agenten in China haben.

Wir bieten eine standardmäßige einjährige Garantie auf alle neuen und originalen Artikel. Wenn Sie eine erweiterte Garantie benötigen, kontaktieren Sie uns bitte für weitere Kostendetails.

Ihre Zufriedenheit ist uns wichtig. Wenn Sie einen Artikel zurückgeben müssen, muss dies innerhalb von 30 Tagen nach dem Bestelldatum erfolgen. Das Produkt muss unbenutzt, ungeöffnet und in der Originalverpackung mit allen Zubehörteilen sein. Rückerstattungen werden innerhalb von 5-7 Werktagen nach Erhalt des zurückgesandten Artikels bearbeitet. Bitte beachten Sie, dass Versand- und damit verbundene Gebühren nicht erstattungsfähig sind.

Hervorgehoben

Ergänzende Produkte