{"id":42880766214234,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"SAI533-H33\/PRP","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Yokogawa SAI533-H33\/PRP Safety Analog Input Module","public_title":null,"options":["Default Title"],"price":26400,"weight":300,"compare_at_price":37800,"inventory_management":"shopify","barcode":"Japan","requires_selling_plan":false,"selling_plan_allocations":[],"quantity_rule":{"min":1,"max":null,"increment":1}}

Beschreibung

Overview

The SAI533-H33/PRP is a safety-rated analog input module developed by Yokogawa for deployment within the ProSafe-RS safety instrumented system. It is engineered to acquire and process critical analog field signals with high integrity while supporting PRP (Parallel Redundancy Protocol) networking to eliminate single points of failure at the communication layer.

Designed for use in high-risk industrial environments, this module delivers deterministic performance, robust diagnostics, and long-term operational stability required for certified safety loops.

Functional Characteristics

The SAI533-H33/PRP provides sixteen independent analog input channels, each electrically isolated to prevent fault propagation and signal interference. The module is optimized for standard 4–20 mA current signals commonly used by safety transmitters measuring pressure, flow, level, and temperature.

Integrated PRP functionality compliant with IEC 62439-3 allows the module to operate on dual Ethernet networks simultaneously, ensuring zero-time recovery from network failures. Combined with ProSafe-RS system redundancy, this architecture supports SIL2 and SIL3 applications when correctly configured.

Key Technical Advantages

High-density 16-channel analog signal acquisition in a single safety module
Native PRP support for seamless network-level redundancy
High-resolution A/D conversion for accurate process value representation
Complete channel-to-channel and channel-to-system isolation
Online replacement capability without stopping the safety controller
Built-in diagnostics covering input status, wiring faults, and internal health
Clear front-panel LED indicators for maintenance and troubleshooting

Electrical and Performance Specifications

Input signal type: 4–20 mA current (safety transmitter compatible)
Number of inputs: 16 isolated channels
A/D conversion: 16-bit resolution typical of the SAI series
Input impedance: Optimized for loop-powered field devices
Isolation rating: Channel-to-channel and channel-to-bus galvanic isolation
Power supply: Logic and field power supplied via ProSafe-RS baseplate

Network and Safety Compliance

Network protocol: PRP (Parallel Redundancy Protocol)
Standard reference: IEC 62439-3
Safety integrity: Suitable for SIL2 / SIL3 safety functions in redundant systems
Diagnostics coverage: Supports safety integrity calculations and proof testing

Environmental and Mechanical Data

Operating temperature range: 0 °C to 55 °C
Storage temperature range: −40 °C to 70 °C
Relative humidity: 5–95% non-condensing
Cooling method: Natural air convection
Installation: ProSafe-RS FIO baseplate slot
Maintenance: Hot-swap supported under system power

Typical Applications

Emergency shutdown systems (ESD)
Fire and gas detection systems (F&G)
Critical process interlocks in oil & gas and petrochemical plants
Turbine and boiler protection systems in power generation
High-availability safety loops requiring network redundancy

FAQ

Q: What is the benefit of PRP in the SAI533-H33/PRP?
A: PRP allows the module to communicate over two independent Ethernet networks simultaneously, providing uninterrupted data flow even if one network fails.

Q: Can this module be used in non-redundant systems?
A: While the module can operate in various architectures, SIL2/SIL3 certification requires use within a properly designed redundant ProSafe-RS system.

Q: Is the module limited to 4–20 mA inputs only?
A: The primary supported signal type is 4–20 mA, which aligns with most safety-rated field transmitters used in SIS applications.

Zeig mehr

Wir begrüßen Großbestellungen und haben eine Mindestbestellmenge von nur einer Einheit.

Auf Anfrage können wir alle notwendigen Dokumente bereitstellen, einschließlich Ursprungs-/Konformitätszertifikate und andere erforderliche Exportdokumente.

Für vorrätige Artikel streben wir eine Lieferung innerhalb von 1-3 Tagen nach Zahlungseingang an. Artikel mit angegebenen Lieferzeiten werden gemäß dem angegebenen Zeitplan geliefert.

Wir akzeptieren 100% T/T (Telegraphische Überweisung) Zahlung vor dem Versand. Für Artikel mit Lieferzeiten ist eine Anzahlung von 30% im Voraus erforderlich, der verbleibende Rest von 70% ist vor dem Versand fällig. Für RMB-Überweisungen kontaktieren Sie uns bitte, wenn Sie einen Agenten in China haben.

Wir bieten eine standardmäßige einjährige Garantie auf alle neuen und originalen Artikel. Wenn Sie eine erweiterte Garantie benötigen, kontaktieren Sie uns bitte für weitere Kostendetails.

Ihre Zufriedenheit ist uns wichtig. Wenn Sie einen Artikel zurückgeben müssen, muss dies innerhalb von 30 Tagen nach dem Bestelldatum erfolgen. Das Produkt muss unbenutzt, ungeöffnet und in der Originalverpackung mit allen Zubehörteilen sein. Rückerstattungen werden innerhalb von 5-7 Werktagen nach Erhalt des zurückgesandten Artikels bearbeitet. Bitte beachten Sie, dass Versand- und damit verbundene Gebühren nicht erstattungsfähig sind.

Hervorgehoben

Ergänzende Produkte