Description
Overview
The EPRO CON041 combined with the PR6423/00R-001 eddy current sensor delivers a high-accuracy, non-contact monitoring solution for rotating machinery. This set enables precise measurement of shaft displacement, vibration, and position in demanding industrial environments, including steam, gas, and hydro turbines, compressors, and pumps. The PR6423/00R-001 probe generates raw eddy current signals, while the CON041 conditions these signals and provides standardized voltage outputs suitable for integration into machine monitoring and protection systems.
Technical Specifications
| Specification | Details |
|---|---|
| System Type | Eddy current sensor and signal converter set |
| Sensor Model | PR6423/00R-001 (eddy current probe) |
| Converter Model | CON041 |
| Frequency Response | 0–20 kHz (-3 dB) |
| Rise Time | ≤15 µs |
| Supply Voltage | -23V to -32V (Output -4V to -20V) or -21V to -32V (Output -2V to -18V) |
| Output Signal | Standardized analog voltage for monitoring and protection systems |
| Operating Temperature | -30°C to +100°C |
| Shock & Vibration | 5 g @ 60 Hz |
| Protection Class | IP20 |
| Housing Material | ALMgSi 0.5 F22 |
| Dimensions | 8 × 5 × 3 cm |
| Weight | 0.25 kg |
| Mounting | 4 × M5×20 screws (included) |
Key Features
-
Complete sensor-converter solution for accurate and reliable signal conditioning.
-
Non-contact measurement ensures long-term durability and eliminates mechanical wear.
-
High dynamic response supports frequency ranges up to 20 kHz with fast rise times.
-
Compact, robust design for harsh industrial conditions.
-
Standardized output simplifies integration with monitoring and protection systems.
Applications
Ideal for use in turbines, compressors, pumps, and other rotating machinery where precise displacement, vibration, and position measurements are critical for safety, efficiency, and condition monitoring.
FAQ
Q: Can the CON041 work with other PR6423 series sensors?
A: The CON041 is optimized for the PR6423/00R-001 but may support other PR6423 variants with minor configuration adjustments.
Q: What output types are supported for integration?
A: Standardized analog voltage output compatible with most machine monitoring and protection systems.
Q: How is the unit mounted?
A: The converter is secured using the included 4 M5×20 screws, supporting compact installation in control panels or machinery enclosures.
Q: Is the device suitable for high-temperature environments?
A: Yes, it operates reliably in temperatures ranging from -30°C to +100°C.
Fonctionnalités
Nous acceptons les commandes en gros et avons une quantité minimale de commande d'une seule unité.
Sur demande, nous pouvons fournir toute la documentation nécessaire, y compris les certificats d'origine/de conformité et autres documents d'exportation requis.
Pour les articles en stock, nous visons une livraison sous 1 à 3 jours après confirmation du paiement. Les articles avec des délais spécifiés seront livrés selon le calendrier indiqué.
Nous acceptons le paiement à 100 % par T/T (virement télégraphique) avant l'expédition. Pour les articles avec des délais de livraison, un acompte de 30 % est requis à l'avance, le solde de 70 % étant dû avant l'expédition. Pour les transferts en RMB, veuillez nous contacter si vous avez un agent en Chine.
Nous offrons une garantie standard d'un an sur tous les articles neufs et d'origine. Si vous souhaitez une garantie prolongée, veuillez nous contacter pour plus de détails sur les coûts supplémentaires.
Votre satisfaction est importante pour nous. Si vous devez retourner un article, cela doit être fait dans les 30 jours suivant la date de la commande. Le produit doit être inutilisé, non ouvert, et dans son emballage d'origine avec tous les accessoires inclus. Les remboursements sont traités dans les 5 à 7 jours ouvrables après réception de l'article retourné. Veuillez noter que les frais de livraison et les frais connexes ne sont pas remboursables.