The GE 745-W2-P5-G5-HI-A-L-R-E-H is a high-performance transformer protection relay designed for medium and large power transformers. Part of the GE Multilin 745 series, this relay integrates advanced protection, control, metering, and communication in a single, compact device, providing reliable operation in utility substations, power plants, and industrial installations.
Technical Specifications
-
Model: 745-W2-P5-G5-HI-A-L-R-E-H
-
Manufacturer: General Electric (GE)
-
Series: Multilin 745 Transformer Protection System
-
Type: Digital Transformer Protection Relay
-
Protection Functions: Differential, restricted earth fault (REF), overcurrent, thermal overload, overvoltage, undervoltage, frequency protection
-
Current Inputs (CT): Configurable for 1 A or 5 A
-
Voltage Inputs (PT): 100–120 V AC
-
Auxiliary Power: 88–300 V DC / 85–265 V AC (HI range)
-
Control Features: Breaker trip/close, programmable logic functions, remote control
-
Metering: Current, voltage, power, frequency, harmonics
-
Communication Interfaces: RS-232, RS-485, Ethernet (dependent on configuration)
-
Supported Protocols: Modbus RTU/TCP, DNP3, IEC 61850 (configuration-dependent)
-
Display: Large LCD with programmable mimic diagrams
-
Event Recording: Sequence of Events (SOE) with millisecond resolution
-
Oscillography: Fault waveform capture for detailed analysis
-
Weight: 10 lbs
-
Operating Temperature: -40 °C to +60 °C
Key Features
-
Full transformer protection including differential and REF
-
Integrated breaker management and bay control
-
High-speed event recording with oscillography for fault diagnostics
-
Advanced metering with harmonic analysis
-
Flexible communication options for SCADA and substation automation
-
User-friendly interface with programmable mimic diagrams
Typical Applications
-
Utility substations: protection for medium and large transformers
-
Power plants: ensuring reliable operation of critical transformers
-
Industrial facilities: safeguarding essential transformer equipment
-
Smart grids: integration with SCADA and automated control systems
FAQ
Q: What CT and PT ranges are supported?
A: The relay supports 1 A or 5 A CTs and 100–120 V AC PTs.
Q: Can it communicate with IEC 61850 systems?
A: Yes, IEC 61850 support is available depending on the configuration.
Q: What is the auxiliary power requirement?
A: 88–300 V DC or 85–265 V AC (HI range).
Q: Does it support event and fault recording?
A: Yes, it includes SOE with millisecond resolution and fault waveform capture.
Q: How does it differ from other 745 variants?
A: This configuration includes high-range auxiliary power, full differential and REF protection, and advanced communication interfaces.
Fonctionnalités
Nous acceptons les commandes en gros et avons une quantité minimale de commande d'une seule unité.
Sur demande, nous pouvons fournir toute la documentation nécessaire, y compris les certificats d'origine/de conformité et autres documents d'exportation requis.
Pour les articles en stock, nous visons une livraison sous 1 à 3 jours après confirmation du paiement. Les articles avec des délais spécifiés seront livrés selon le calendrier indiqué.
Nous acceptons le paiement à 100 % par T/T (virement télégraphique) avant l'expédition. Pour les articles avec des délais de livraison, un acompte de 30 % est requis à l'avance, le solde de 70 % étant dû avant l'expédition. Pour les transferts en RMB, veuillez nous contacter si vous avez un agent en Chine.
Nous offrons une garantie standard d'un an sur tous les articles neufs et d'origine. Si vous souhaitez une garantie prolongée, veuillez nous contacter pour plus de détails sur les coûts supplémentaires.
Votre satisfaction est importante pour nous. Si vous devez retourner un article, cela doit être fait dans les 30 jours suivant la date de la commande. Le produit doit être inutilisé, non ouvert, et dans son emballage d'origine avec tous les accessoires inclus. Les remboursements sont traités dans les 5 à 7 jours ouvrables après réception de l'article retourné. Veuillez noter que les frais de livraison et les frais connexes ne sont pas remboursables.