Passer au contenu
Honeywell FTA-T-16 Fail-Safe Digital Input FTA

Honeywell FTA-T-16 Fail-Safe Digital Input FTA

  • 1000 En stock
  • Manufacturer: HONEYWELL

  • Product No.: FTA-T-16

  • Condition: En stock

  • Product Type: Fail-Safe Digital Input FTA

  • Product Origin: USA

  • Payment:T/T, Western Union

  • Weight: 250g

  • Shipping port: Xiamen

  • Warranty: 12 months

{"id":42912755286106,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"FTA-T-16","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Honeywell FTA-T-16 Fail-Safe Digital Input FTA","public_title":null,"options":["Default Title"],"price":20900,"weight":250,"compare_at_price":45000,"inventory_management":"shopify","barcode":"USA","requires_selling_plan":false,"selling_plan_allocations":[],"quantity_rule":{"min":1,"max":null,"increment":1}}

Description

Overview

The Honeywell FTA-T-16 (42622268-002) is a fail-safe, active digital input Field Termination Assembly engineered for use with Honeywell Safety Manager and FSC safety control systems. It serves as the interface between field-level discrete devices and safety controllers, ensuring reliable signal acquisition under stringent safety integrity requirements.

This FTA supports sixteen isolated digital input points and incorporates active signal conditioning to detect wiring faults, power anomalies, and abnormal input states. Its design aligns with SIL-rated safety systems where deterministic behavior and fault transparency are mandatory.

Functional Characteristics

The FTA-T-16 (42622268-002) is designed to process discrete on/off signals from safety-related field devices such as emergency stop buttons, limit switches, pressure switches, and interlock contacts. Each channel operates independently to maintain system integrity even in the event of partial failures.

Active circuitry within the FTA enables stable voltage supervision, helping the controller differentiate between valid signals, open circuits, and short conditions. This architecture significantly improves diagnostic coverage compared to passive termination solutions.

Input Channel Specifications

  • Total input points: 16 fail-safe digital channels

  • Supported signal types: Dry contact or powered discrete inputs

  • Nominal input voltage: 24 VDC or 120 VAC (hardware variant dependent)

  • Typical input current: approximately 10 mA per channel

  • Input impedance: nominal 10 kΩ

  • Internal channel isolation: yes, channel-to-channel and field-to-system

For passive field devices, the FTA provides a supervised output supply of approximately 24 VDC. When interfaced with Honeywell safety input modules such as the 10105/2/1, signal levels are conditioned to a low-voltage range of approximately 0–3.5 VDC.

Power Requirements

  • External supply voltage: 30 VDC

  • Maximum current consumption: approximately 150 mA with all inputs energized

  • Power distribution: internally regulated for all 16 channels

Mechanical and Physical Data

  • Dimensions: 110 × 70 × 60 mm
  • Weight: 0.25 kg

The compact form factor allows direct mounting within safety system cabinets while maintaining proper wire separation and labeling clarity.

Environmental Ratings

  • Operating temperature range: –20 °C to +65 °C

  • Storage temperature range: –40 °C to +105 °C

  • Designed for continuous duty in industrial safety environments

System Compatibility

The FTA-T-16 (42622268-002) is fully compatible with:

  • Honeywell Safety Manager systems

  • Honeywell FSC (Fail-Safe Controller) platforms

  • Certified Honeywell safety input modules

It is intended for use in safety instrumented systems requiring high availability and deterministic fault handling.

Typical Applications

  • Emergency shutdown (ESD) systems

  • Safety interlock and permissive logic

  • Burner management and critical equipment protection

  • Plantwide safety instrumented systems (SIS)

Frequently Asked Questions

Q: Is the FTA-T-16 interchangeable with passive digital input FTAs?
A: No. The FTA-T-16 is an active, fail-safe termination assembly with internal supervision circuitry. Passive FTAs do not provide the same diagnostic coverage or fault detection.

Q: Does this FTA perform logic processing?
A: No. The FTA only conditions and terminates field signals. Safety logic execution is performed by the associated Honeywell safety controller.

Q: Can it be used in SIL-rated applications?
A: Yes. When installed as part of a certified Honeywell safety system and used according to system documentation, it supports SIL-rated architectures.

Fonctionnalités

Nous acceptons les commandes en gros et avons une quantité minimale de commande d'une seule unité.

Sur demande, nous pouvons fournir toute la documentation nécessaire, y compris les certificats d'origine/de conformité et autres documents d'exportation requis.

Pour les articles en stock, nous visons une livraison sous 1 à 3 jours après confirmation du paiement. Les articles avec des délais spécifiés seront livrés selon le calendrier indiqué.

Nous acceptons le paiement à 100 % par T/T (virement télégraphique) avant l'expédition. Pour les articles avec des délais de livraison, un acompte de 30 % est requis à l'avance, le solde de 70 % étant dû avant l'expédition. Pour les transferts en RMB, veuillez nous contacter si vous avez un agent en Chine.

Nous offrons une garantie standard d'un an sur tous les articles neufs et d'origine. Si vous souhaitez une garantie prolongée, veuillez nous contacter pour plus de détails sur les coûts supplémentaires.

Votre satisfaction est importante pour nous. Si vous devez retourner un article, cela doit être fait dans les 30 jours suivant la date de la commande. Le produit doit être inutilisé, non ouvert, et dans son emballage d'origine avec tous les accessoires inclus. Les remboursements sont traités dans les 5 à 7 jours ouvrables après réception de l'article retourné. Veuillez noter que les frais de livraison et les frais connexes ne sont pas remboursables.

En vedette

Produits complémentaires