Descrição
Overview
The IC670ALG620 module from GE Fanuc is a high-precision RTD input interface designed for Field Control systems. It supports four independent channels and is compatible with both 3-wire and 4-wire RTD sensors, including Platinum, Nickel, Nickel/Iron, and Copper types. The module converts resistance measurements into accurate temperature data for process monitoring, control applications, and industrial automation systems.
Key Features
-
Four fully isolated RTD input channels for flexible sensor integration
-
Supports 3-wire and 4-wire RTD configurations
-
Configurable measurement ranges: 0–500 Ω or 0–3000 Ω
-
Outputs in resistance (Ω), Celsius (°C), or Fahrenheit (°F) with tenths resolution
-
Built-in diagnostics for open-wire, short-circuit, overrange/underrange, and high/low alarms
-
No external loop power required, reducing installation complexity
-
Industrial-grade reliability for continuous operation
Technical Specifications
| Specification | Details |
|---|---|
| Model Number | IC670ALG620 |
| Input Channels | 4 independent RTD inputs (3-wire or 4-wire) |
| Supported RTD Types | Platinum, Nickel, Nickel/Iron, Copper |
| Resistance Ranges | 0–500 Ω, 0–3000 Ω (selectable) |
| Measurement Units | Ω, °C, °F (tenths resolution) |
| Scan Time | 210 ms (60 Hz), 230 ms (50 Hz) |
| Digital Resolution | 15-bit plus sign |
| Maximum Lead Resistance | 5 Ω per lead |
| Normal Mode Rejection | 60 dB at 50/60 Hz, 100% span |
| Temperature Sensitivity | ±0.004% of reading, ±1.5 mV/°C referred to input (0–60°C) |
| Fault Detection | Open RTD, short, underrange, overrange, high/low alarms |
| Power Requirements | Draws up to 190 mA from BIU supply, no loop power needed |
| Dimensions | 120 × 50 × 100 mm |
| Weight | 0.45 kg |
Applications
Ideal for process control systems, distributed control stations, and temperature monitoring in industrial environments where precise RTD measurements are required. It integrates seamlessly with GE Field Control systems for automated and reliable operation.
FAQ
Q: Can the module measure multiple RTD types simultaneously?
A: Yes, each channel can be individually configured for Platinum, Nickel, Nickel/Iron, or Copper RTDs.
Q: Is external power required for the RTDs?
A: No, the module does not require loop power; it draws power directly from the Bus Interface Unit.
Q: How is configuration performed?
A: The module is configured via a handheld device connected to the main Bus Interface Unit.
Características
Aceitamos encomendas em grande quantidade e temos uma quantidade mínima de encomenda de apenas uma unidade.
Mediante pedido, podemos fornecer toda a documentação necessária, incluindo Certificados de Origem/Conformidade e outros documentos de exportação exigidos.
Para artigos em stock, pretendemos entregar dentro de 1-3 dias após a confirmação do pagamento. Os artigos com prazos de entrega especificados serão entregues de acordo com o calendário indicado.
Aceitamos pagamento 100% T/T (Transferência Telegráfica) antes do envio. Para artigos com prazos de entrega, é necessário um depósito de 30% antecipadamente, com os restantes 70% a pagar antes do envio. Para transferências em RMB, por favor contacte-nos se tiver um agente na China.
Oferecemos uma garantia padrão de um ano em todos os artigos novos e originais. Se necessitar de uma garantia alargada, por favor contacte-nos para obter detalhes sobre custos adicionais.
A sua satisfação é importante para nós. Se precisar de devolver um artigo, deve fazê-lo no prazo de 30 dias a contar da data da encomenda. O produto deve estar por usar, por abrir e na sua embalagem original com todos os acessórios incluídos. Os reembolsos são processados no prazo de 5 a 7 dias úteis após recebermos o artigo devolvido. Por favor, note que os custos de envio e encargos relacionados não são reembolsáveis.