Honeywell FS-TSDO-04UNI Safe Digital Output Module

Honeywell FS-TSDO-04UNI Safe Digital Output Module

  • 1000 Em stock
  • Manufacturer: HONEYWELL

  • Product No.: FS-TSDO-04UNI

  • Condition: Em stock

  • Product Type: Safe Digital Output Module

  • Product Origin: USA

  • Payment:T/T, Western Union

  • Weight: 400g

  • Shipping port: Xiamen

  • Warranty: 12 months

{"id":42912751943770,"title":"Default Title","option1":"Default Title","option2":null,"option3":null,"sku":"FS-TSDO-04UNI","requires_shipping":true,"taxable":true,"featured_image":null,"available":true,"name":"Honeywell FS-TSDO-04UNI Safe Digital Output Module","public_title":null,"options":["Default Title"],"price":20900,"weight":400,"compare_at_price":45000,"inventory_management":"shopify","barcode":"USA","requires_selling_plan":false,"selling_plan_allocations":[],"quantity_rule":{"min":1,"max":null,"increment":1}}

Descrição

Product Overview

The FS-TSDO-04UNI is a safety-rated digital output module developed for Honeywell fault-tolerant safety platforms. It delivers four independent output channels engineered to drive both AC and DC field loads under strict functional-safety constraints. Designed for continuous operation in high-risk industrial facilities, this module forms a reliable interface between the safety controller and final control elements such as solenoids, relays, and shutdown devices.

Integrated seamlessly into Honeywell FSC architectures, the module supports safety instrumented functions (SIFs) that demand deterministic behavior, electrical isolation, and predictable failure modes.

Key Functional Characteristics

The FS-TSDO-04UNI provides four galvanically isolated output channels, each designed with fail-safe behavior to ensure outputs transition to a defined safe state during power loss, internal fault detection, or system shutdown.

The outputs are designed to accommodate universal load types, allowing the same channel design to switch low-voltage DC devices as well as higher-voltage AC actuators. This flexibility reduces I/O diversity while maintaining compliance with international safety standards.

Electrical and Output Specifications

  • Four independent safety-rated digital output channels

  • Galvanic isolation between channels and system backplane

  • Universal load capability supporting both AC and DC field devices

  • Maximum switching voltage up to 50 V DC (Overvoltage Category III)

  • Maximum switching voltage up to 150 V DC (Overvoltage Category II)

  • Designed for deterministic response in safety logic execution

  • Output state monitoring for safety diagnostics and fault reporting

Safety, Compliance, and Certification

The FS-TSDO-04UNI is certified for use in safety-critical applications and complies with major global regulatory frameworks, making it suitable for deployment in regulated process industries.

  • CE conformity for European installations

  • TÜV certification for functional safety compliance

  • UL and CSA approval for North American markets

  • FM certification for use in hazardous and high-reliability environments

These certifications support use in SIL-rated safety instrumented systems when applied according to Honeywell safety manuals.

Mechanical and Installation Details

  • Compact module design optimized for 19-inch rack-mounted safety systems

  • Standard module dimensions approximately 60 × 70 × 54 mm

  • Optional field termination assembly (FTA) variant available

  • Dimensions: 45 × 120 × 130 mm

  • Weight 0.4 kg

  • Manufactured in the United States

The compact footprint allows high I/O density while maintaining adequate spacing for heat dissipation and wiring access.

Typical Application Areas

The FS-TSDO-04UNI is commonly deployed in environments where output reliability directly affects personnel safety and asset protection, including:

  • Emergency shutdown systems in oil and gas facilities

  • Burner management and combustion safety systems

  • Chemical reactor isolation and venting control

  • Power generation protection and turbine shutdown logic

Frequently Asked Questions

Q: Can the FS-TSDO-04UNI drive both AC and DC loads on the same module?
A: Yes. Each output channel is designed to support universal AC or DC loads within the specified voltage limits.

Q: What happens to the outputs during a system fault or power loss?
A: The module is fail-safe by design. Outputs transition to a predefined safe state as required by the safety logic configuration.

Q: Is this module compatible with standard Honeywell FSC controllers?
A: Yes. The FS-TSDO-04UNI is specifically designed for integration into Honeywell FSC fault-tolerant safety systems.

Características

Aceitamos encomendas em grande quantidade e temos uma quantidade mínima de encomenda de apenas uma unidade.

Mediante pedido, podemos fornecer toda a documentação necessária, incluindo Certificados de Origem/Conformidade e outros documentos de exportação exigidos.

Para artigos em stock, pretendemos entregar dentro de 1-3 dias após a confirmação do pagamento. Os artigos com prazos de entrega especificados serão entregues de acordo com o calendário indicado.

Aceitamos pagamento 100% T/T (Transferência Telegráfica) antes do envio. Para artigos com prazos de entrega, é necessário um depósito de 30% antecipadamente, com os restantes 70% a pagar antes do envio. Para transferências em RMB, por favor contacte-nos se tiver um agente na China.

Oferecemos uma garantia padrão de um ano em todos os artigos novos e originais. Se necessitar de uma garantia alargada, por favor contacte-nos para obter detalhes sobre custos adicionais.

A sua satisfação é importante para nós. Se precisar de devolver um artigo, deve fazê-lo no prazo de 30 dias a contar da data da encomenda. O produto deve estar por usar, por abrir e na sua embalagem original com todos os acessórios incluídos. Os reembolsos são processados no prazo de 5 a 7 dias úteis após recebermos o artigo devolvido. Por favor, note que os custos de envio e encargos relacionados não são reembolsáveis.

Destaques

Produtos complementares